Xuyang Zhong

Xuyang Zhong


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2024 in Buildings
Verified
Journal Article
Open access
PDF file
XZXuyang Zhong
Xuyang Zhong
MCMing Cai
Ming Cai
ZWZhe Wang
Zhe Wang
ZZZhiang Zhang
Zhiang Zhang
RZRuijun Zhang
Ruijun Zhang
The heat rejected by outdoor units of split A/C conditioners can impact the ambient outdoor environment of mixed-mode buildings. Nevertheless, how this environmental impact may affect the space-conditioning energy use and indoor air pollution is poorly understood. By coupling EnergyPlus and Fluent, this study examines the effects of outdoor units’ heat rejection on the building surroundings, building cooling load, and indoor PM2.5 exposure of a six-storey mixed-mode building. The building had an open-plan room on each floor, with the outdoor unit positioned below the window. The coupled model was run for a selected day when the building was cooled by air conditioning and natural ventilation. Five mixed-mode cooling strategies were simulated, reflecting different window-opening schedules, airflow rates of outdoor units, and cooling set-points. The results indicate that compared with the always-air-conditioned mode, the mixed-mode operation could significantly mitigate the negative impact of heat rejection on space-cooling energy consumption. Increasing the airflow rate of outdoor units led to a lower increase in demand for space cooling and lower indoor PM2.5 exposure. If one of the six rooms needs to be cooled to a lower temperature than the others; choosing the bottom-floor room helped achieve more energy savings and better indoor air quality.

26 September 2023 in Buildings
Verified
Journal Article
Open access
PDF file
XZXuyang Zhong
Xuyang Zhong
ZZZhiang Zhang
Zhiang Zhang
RZRuijun Zhang
Ruijun Zhang
ZWZijian Wu
Zijian Wu
Exterior shading devices and outdoor units can be closely coupled since these two building components are commonly installed next to each other. This study uses a coupled EnergyPlus-Fluent modeling approach to examine how a combination of exterior shading and heat rejection from outdoor units can affect the ambient outdoor environment of a building, and how changes in the ambient outdoor environment can influence cooling loads and indoor PM2.5 exposure. Three exterior shading devices were simulated, including horizontal overhangs, vertical overhangs, and vertical fins. Data from wind-tunnel experiments and field measurements were used to ensure the accuracy of the airflow model, energy model, and pollution model developed in this study. Results indicate that horizontal overhangs could almost offset the increase in cooling loads due to increased ambient outdoor temperatures caused by heat rejection. The use of vertical overhangs did not always mean lower demand for space cooling when heat rejection was considered. Heat rejection, horizontal overhangs, and vertical overhangs could help reduce indoor PM2.5 exposure, while indoor air pollution was worse after the implementation of vertical fins. This study shows how exterior shading devices and outdoor units can be coupled to achieve better building energy efficiency and improved occupant health.

15 January 2025 in Science of The Total Environment
Verified
Journal Article
Closed access
XZXuyang Zhong
Xuyang Zhong
ZZZhiang Zhang
Zhiang Zhang
RZRuijun Zhang
Ruijun Zhang