Gang Li

Dr. Gang Li


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Science Bulletin
Verified
Journal Article
Closed access
LXLida Xing
Lida Xing
JOJingmai K. O'Connor
Jingmai K. O'Connor
RMRyan Christopher McKellar
Ryan Christopher McKellar
LCLuis M. Chiappe
Luis M. Chiappe
MBMing Bai
Ming Bai
GLGang Li
Gang Li

12 August 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
RSRui Sun
Rui Sun
YWYanping Wang
Yanping Wang
JZJie Zhang
Jie Zhang
TDTijian Deng
Tijian Deng
QYQiru Yi
Qiru Yi
XJXiaoming Jiang
Xiaoming Jiang
In synchrotron radiation X-ray imaging, the imaging field of view and spatial resolution are mutually restricted, which makes it impossible to have both a large field of view and high resolution when carrying out experiments. Constructing an oversampled image through the micro-scanning method and using the deconvolution algorithm to eliminate the point spread function introduced by pixel overlap can increase the resolution under a fixed imaging field of view, thereby improving the ratio of the field of view to the spatial resolution. In this paper, numerical simulation and synchrotron radiation experiments are carried out with a different number of micro-scanning steps. In numerical simulation experiments only affected by the image pixel size, as the number of micro-scanning steps increases, the ability of the oversampled image with deconvolution to improve the resolution is stronger. The achievable resolution of the oversampled image with deconvolution is basically the same as that of the sample image. In the synchrotron radiation experiments, the resolution of the oversampled image with deconvolution in the 2 × 2 mode is significantly improved. However, as the number of micro-scanning steps increases, the resolution improvement is limited, or even no longer improved. Finally, by analyzing the results of numerical simulation and synchrotron radiation experiments, three factors (four other factors affecting the resolution besides the camera resolution, translational accuracy of micro-scanning, and the signal-to-noise ratio of projections) affecting the micro-scanning method are proposed and verified by experiments.

12 April 2005 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
GLGang Li
Gang Li
CZChen Zhihua
Chen Zhihua
WZWu Ziyu
Wu Ziyu
MAM. Ando
M. Ando
PLPan Lin
Pan Lin
XJX.M. Jiang
X.M. Jiang

21 June 2024 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
DZDongni Zhang
Dongni Zhang
MLMing Li
Ming Li
XLXiaoyu Li
Xiaoyu Li
HLHuihua Lu
Huihua Lu
YLYuhui Li
Yuhui Li
PLPeng Liu
Peng Liu
A novel insertion device is introduced, designated as the Mango wiggler, designed for synchrotron radiation (SR) imaging that provides a large field of view. This innovative device is constructed from two orthogonal planar wigglers with a small difference in their period lengths, eliciting the phase difference of the magnetic fields to incrementally transitions from 0 to π/2. Such a configuration enlarges the vertical divergence of the light source, as with the horizontal divergence. The appellation `Mango wiggler' derives from the distinctive mango-shaped contour of its radiation field. A comprehensive suite of theoretical analyses and simulations has been executed to elucidate the radiation properties of the Mango wiggler, employing SPECTRA and Mathematica as calculation tools. In conjunction with the ongoing construction of the High Energy Photon Source in Beijing a practical Mango wiggler device has been fabricated for utilization in SR imaging applications. Theoretical analyses were applied to this particular Mango wiggler to yield several theoretical conclusions, and several simulations were performed according to the measured magnetic field results.


1 October 2004 in Chinese Science Bulletin
Verified
Journal Article
Open access
PDF file
GLGang Li
Gang Li
NWNan Wang
Nan Wang
ZWZiyu Wu
Ziyu Wu
Different configurations for the monochromator crystals and the analyzer crystals have been used in hard X-ray diffraction enhanced imaging (DEI) methods to over-come the complex task to adjust each of them to the ideal position. Here we present a very compact DEI configuration, and preliminary results of experiments performed at the Beijing Synchrotron Radiation Facility (BSRF) using only two crystals: the first one acting as monochromator and the second one as analyzer in the Bragg geometry. Refraction contrast images characterized by high contrast and spatial resolution are obtained and compared with absorption images. Differences among these images will be outlined and discussed emphasizing the potential capabilities of this very simple layout that guarantees a high transmission efficiency.