Single-cell microrobots are new microartificial devices that use a combination of single cells and artificial devices, with the advantages of small size, easy degradation and ease of manufacture. With externally driven strategies such as light fields, sound fields and magnetic fields, microrobots are able to carry out precise micromanipulations and movements in complex microenvironments. Therefore, single-cell microrobots have received more and more attention and have been greatly developed in recent years. In this paper, we review the main classifications, control methods and recent advances in the field of single-cell microrobot applications. First, different types of robots, such as cell-based microrobots, bacteria-based microrobots, algae-based microrobots, etc., and their design strategies and fabrication processes are discussed separately. Next, three types of external field-driven technologies, optical, acoustic and magnetic, are presented and operations realized in vivo and in vitro by applying these three technologies are described. Subsequently, the results achieved by these robots in the fields of precise delivery, minimally invasive therapy are analyzed. Finally, a short summary is given and current challenges and future work on microbial-based robotics are discussed.
Multi-point array thin-film thermocouples have strong potential for high-precision, wide-range temperature monitoring in applications such as aircraft engine thermal condition assessment and industrial process control. However, conventional single-point thin-film thermocouples cannot satisfy the distributed measurement requirements of large-area temperature fields, and the accuracy of multi-point arrays is often degraded by coupling effects among sensing nodes, which hinders their engineering deployment. In this work, a multi-point array thin-film thermocouple is fabricated via precision welding, and an insulating layer is deposited on the sensor surface using electrospray atomization to establish a multi-point temperature-sensing hardware system. To compensate for coupling-induced deviations, a deep learning–based calibration method is developed: measurements from the array and reference thermocouples are synchronously collected to build the dataset, outliers are removed using the interquartile range (IQR) method, and a three-hidden-layer multilayer perceptron (MLP) is trained for each node independently using the Adam optimizer (learning rate 0.001) with an 8:2 train–test split. Performance is quantified by MAE, MSE, and R2, and the results show that the proposed approach markedly reduces measurement errors and improves the accuracy of the array thermocouples, demonstrating reliable performance and practical applicability for precise large-area temperature-field monitoring.