As a convenient and natural way of human-computer interaction, gesture recognition technology has broad research and application prospects in many fields, such as intelligent perception and virtual reality. This paper summarized the relevant literature on gesture recognition using Frequency Modulated Continuous Wave (FMCW) millimeter-wave radar from January 2015 to June 2023. In the manuscript, the widely used methods involved in data acquisition, data processing, and classification in gesture recognition were systematically investigated. This paper counts the information related to FMCW millimeter wave radar, gestures, data sets, and the methods and results in feature extraction and classification. Based on the statistical data, we provided analysis and recommendations for other researchers. Key issues in the studies of current gesture recognition, including feature fusion, classification algorithms, and generalization, were summarized and discussed. Finally, this paper discussed the incapability of the current gesture recognition technologies in complex practical scenes and their real-time performance for future development.
The detection of respiration rate (RR) and heart rate (HR) using frequency-modulated continuous wave (FMCW) millimeter-wave (MMW) radar has numerous applications across different domains. Most existing studies focus on one or two aspects of the processing pipeline. This paper presents RH-AVSWM, an algorithm consisting of four modules that provide more accurate estimates of RR and HR. The adaptive random body movements (RBM) inhibition algorithm is utilized to eliminate RBM through range-bin selection and phase compensation. The variational mode decomposition optimized via the Sparrow Search Algorithm(SSA) enhances vital-sign signal extraction. Weight reconstruction is employed to mitigate clutter and respiration harmonics in HR signals, while multiple signal classification improves spectral resolution for distinguishing RR and HR. Comprehensive experiments were conducted using a public dataset and data obtained with a realistic FMCW MMW radar, considering variables such as monitoring distance, incident angle, and body motion. The results indicate that the mean absolute error (MAE) is 0.49 bpm for RR and 1.24 bpm for HR, reducing to 0.23 bpm and 0.70 bpm, respectively, under optimal conditions (0.5 m distance, no body motion, and direct incidence). Through ablation experiments, the contribution of each module to the overall performance (regarding accuracy and robustness) of RH-AVSWM has been assessed. Given that RH-AVSWM achieves comparable or superior performance relative to state-of-the-art results, it holds promise for a wide range of applications in healthcare.