To improve assessment of ventricular function during cardiac catheterisation there should be available a continuous registration of stroke volume and cardiac output in addition to ventricular pressure. To obtain the desired volumetric quantities a catheter has been developed which measures changes in intraventricular dimensions by electrical impedance. For this purpose, the catheter is equipped with eight electrodes spaced over a distance equal to the long axis of the left ventricle into which it is introduced. A constant current is imposed between the outermost electrodes while the inner six are used to measure resistance of volume segments of the blood contained within the ventricular cavity. The difference in resistance at the beginning and end of ejection is proportional to the contribution of each segment to stroke volume, which follows from addition of the segmental terms. Calibration is obtained by measuring electrical conductivity of a blood sample. The catheter was tested over a tenfold range of cardiac output, both in vitro, using an artificial heart model, while performance in vivo was evaluated in 12 dogs. In the animal study, stroke volume and cardiac output from the catheter were compared with flows obtained with an electromagnetic flowmeter. In both studies, linear regression analysis showed excellent correlation of cardiac output (r = 0.99, n = 10 in vitro, r = 0.95, n = 126 in vivo) while the regression equations were close to those of identity. Very good correlation (r = 0.98, n = 28) was also obtained for stroke volumes on a beat to beat basis during arrhythmia. It is concluded that the catheter, which has great potential for application in man, fulfills its primary aim of continuously recording stroke volume and cardiac output.
Ejection fraction (EF) is commonly applied as a clinically relevant metric to assess ventricular function. The numerical value of EF depends on the interplay between end-systolic volume (ESV) and end-diastolic volume (EDV). Remarkably, the relative impact of the two constitutive components on EF received little attention. Three patient groups not using beta-blockers were analyzed for a robust investigation into the relative contribution of ESV and EDV when assessing EF: cardiac patients (N=155) with left ventricular (LV) data obtained by biplane ventriculography, near-normals (N=276) by gated SPECT investigation, and an MRI-based post Fallot repair study including right ventricular (RV) data (N=124), besides LV. We compared various routes to evaluate EF via linear and several types of nonlinear regression with ESV as independent variable. Advanced statistics was applied to evaluate sex-specific differences. In all cases ESV emerges as the dominant component of EF, with less (P<0.0001) impact of EDV. The relationship for EF versus ESV is nonlinear (P<0.0001), and similar for both sexes. A linear approach may be inadequate and generate erroneous statistical outcomes when comparing subgroups of patients. Values for EF primarily depend on ESV, both for LV and RV. This relationship is essentially nonlinear, and similar for both sexes. A logarithmic approximation is convenient and often acceptable. However, application of linear regression for EF vs ESV may lead to incorrect conclusions, particularly when comparing males and females.
Cardiovascular investigations often involve ratio-based metrics or differences: ejection fraction, arterial pressure augmentation index, coronary fractional flow reserve, pulse pressure. Focusing on a single number (ratio or difference) implies that information is lost. The lost companions constitute a well-defined but thus far unrecognized class, having additive value, a physical dimension, and often a physiological meaning. Physiologists should play a prominent role in exploring these complementary avenues and also define alternatives.