Nicolas Elie

Mr. Nicolas Elie

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2018 in Analytical Chemistry
Verified
Journal Article
Closed access
FOFlorent Olivon
Florent Olivon
NENicolas Elie
Nicolas Elie
GGGwendal Grelier
Gwendal Grelier
FRFanny Roussi
Fanny Roussi
Marc LitaudonMarc Litaudon
Marc Litaudon
DTDavid Touboul
David Touboul

26 May 2015 in Rapid Communications in Mass Spectrometry
Verified
Journal Article
Open access
PDF file
QVQuentin P. Vanbellingen
Quentin P. Vanbellingen
NENicolas Elie
Nicolas Elie
MEMichael J. Eller
Michael J. Eller
SDSerge Della‐Negra
Serge Della‐Negra
DTDavid Touboul
David Touboul
ABAlain Brunelle
Alain Brunelle
Rationale: In Time‐of‐Flight Secondary Ion Mass Spectrometry (TOF‐SIMS), pulsed and focused primary ion beams enable mass spectrometry imaging, a method which is particularly useful to map various small molecules such as lipids at the surface of biological samples. When using TOF‐SIMS instruments, the focusing modes of the primary ion beam delivered by liquid metal ion guns can provide either a mass resolution of several thousand or a sub‐µm lateral resolution, but the combination of both is generally not possible. Methods: With a TOF‐SIMS setup, a delayed extraction applied to secondary ions has been studied extensively on rat cerebellum sections in order to compensate for the effect of long primary ion bunches. Results: The use of a delayed extraction has been proven to be an efficient solution leading to unique features, i.e. a mass resolution up to 10000 at m/z 385.4 combined with a lateral resolution of about 400 nm. Simulations of ion trajectories confirm the experimental determination of optimal delayed extraction and allow understanding of the behavior of ions as a function of their mass‐to‐charge ratio. Conclusions: Although the use of a delayed extraction has been well known for many years and is very popular in MALDI, it is much less used in TOF‐SIMS. Its full characterization now enables secondary ion images to be recorded in a single run with a submicron spatial resolution and with a mass resolution of several thousand. This improvement is very useful when analyzing lipids on tissue sections, or rare, precious, or very small size samples. © 2015 The Authors. Rapid Communications in Mass Spectrometry published by John Wiley & Sons Ltd.

17 January 2018 in Analytical Chemistry
Verified
Journal Article
Closed access
SNSebastiaan Van Nuffel
Sebastiaan Van Nuffel
NENicolas Elie
Nicolas Elie
EYEthan Yang
Ethan Yang
JNJulius Nouet
Julius Nouet
DTDavid Touboul
David Touboul
ABAlain Brunelle
Alain Brunelle

28 July 2020 in Analytical Chemistry
Verified
Journal Article
Closed access
SNSebastiaan Van Nuffel
Sebastiaan Van Nuffel
MQMarceau Quatredeniers
Marceau Quatredeniers
APAlexander Pirkl
Alexander Pirkl
JZJulia Zakel
Julia Zakel
JCJean-Pierre Le Caer
Jean-Pierre Le Caer
ABAlain Brunelle
Alain Brunelle

1 September 2015 in Food Chemistry
Verified
Journal Article
Closed access
KCKarim Chouaïb
Karim Chouaïb
FHFayçal Hichri
Fayçal Hichri
ANAsma Nguir
Asma Nguir
MDMajda Daami-Remadi
Majda Daami-Remadi
NENicolas Elie
Nicolas Elie
MHM’hAmed Ali Hamza
M’hAmed Ali Hamza

20 August 2019 in Analytical Chemistry
Verified
Journal Article
Open access
NENicolas Elie
Nicolas Elie
Cyrille santerreCyrille santerre
Cyrille santerre
DTDavid Touboul
David Touboul
Molecular networks (MN) allows to organize tandem mass spectrometry (MS/MS) data by spectral similarities. Cosine-score used as a metric to calculate the distance between two spectra is based on peak lists containing fragments and neutral losses from MS/MS spectra. Until now the workflow excluded the generation of molecular network from electron ionization (EI) MS data as no selection of the putative parent ion is achieved when performing classical gas chromatography (GC)-EI-MS analysis. In order to fill this gap, new functionalities on MetGem 1.2.2 software (https://github.com/metgem/metgem/releases ) have been implemented and results from a large EI-MS database and GC-EI-MS analysis will be exemplified.