Ondřej Kabot

Mr. Ondřej Kabot

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
NXNing Xu
Ning Xu
WWWensong Wang
Wensong Wang
JFJan Fulneček
Jan Fulneček
OKOndřej Kabot
Ondřej Kabot
SMStanislav Mišák
Stanislav Mišák
HGHoay Beng Gooi
Hoay Beng Gooi
Partial discharge (PD) of overhead lines is an indication of imminent dielectric breakdown and a cause of insulation degradation. Efficient PD detection is the significant foundation of electrical system maintenance. This article proposes a transformer-based multilevel filtering (TBMF) framework for PD detection. It creates the multilevel filtering mechanism to be robust to large-scale industrial measurements contaminated with a variety of background noises and plenty of invalid information. The primary filtering innovatively creates the principle of possible PD measurements to replace feature extraction and reduce manual intervention. For the first time, multiple transformer-based algorithms are introduced to the PD detection field to process the possible PD measurements without relying on the sequence order. The secondary filtering then refines the segmentation-level results from the primary filtering and outputs the overall detection results. Multiple numerical algorithms, artificial intelligence models, and intelligent metaheuristic optimization have been adopted as methodologies of the secondary filtering. The TBMF framework is experimentally verified by extensive field trial data of medium-voltage overhead power lines. Its detection accuracy reaches 96.1 $\%$ , which outperforms other techniques in the literature. It provides an economic and complete PD detection solution to maintain the economical and safe operation of power systems.

10 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
OKOndřej Kabot
Ondřej Kabot
LKLukáš Klein
Lukáš Klein
LPLukas Prokop
Lukas Prokop
Wojciech WalendziukWojciech Walendziuk
Wojciech Walendziuk
This study introduces an innovative approach to enhance fault detection in XLPE-covered conductors used for power distribution systems. These covered conductors are widely utilized in forested areas (natural parks) to decrease the buffer zone and increase the reliability of the distribution network. Recognizing the imperative need for precise fault detection in this context, this research employs an antenna-based method to detect a particular type of fault. The present research contains the classification of fault type detection, which was previously accomplished using a very expensive and challenging-to-install galvanic contact method, and only to a limited extent, which did not provide information about the fault type. Additionally, differentiating between types of faults in the contact method is much easier because information for each phase is available. The proposed method uses antennas and a classifier to effectively differentiate between fault types, ranging from single-phase to three-phase faults, as well as among different types of faults. This has never been done before. To bolster the accuracy, a stacking ensemble method involving the logistic regression is implemented. This approach not only advances precise fault detection but also encourages the broader adoption of covered conductors. This promises benefits such as a reduced buffer zone, improved distribution network reliability, and positive environmental outcomes through accident prevention and safe covered conductor utilization. Additionally, it is suggested that the fault type detection could lead to a decrease in false positives.

5 August 2025 in Scientific Data
Verified
Journal Article
Open access
PDF file
OKOndřej Kabot
Ondřej Kabot
LKLukáš Klein
Lukáš Klein
ZSZdenek Slanina
Zdenek Slanina
LPLukáš Prokop
Lukáš Prokop
Accurate differentiation between partial discharges (PD) and corona discharges in XLPE-covered conductors is crucial for power system diagnostics, yet remains limited by the lack of specialized, high-fidelity datasets for machine learning (ML) model development. This paper presents a high-resolution dataset (107 samples per 20 ms) acquired using a contactless dual-antenna system under controlled laboratory conditions simulating medium-voltage overhead distribution lines. The dataset includes 100 labeled measurements per class across five discharge types (PD, corona, mixed states, and high-impedance variants) and two background conditions (with and without high voltage), collected over a two-day campaign. By providing experimentally isolated signal types, this resource enables the development and benchmarking of ML models specifically tailored to the PD–corona classification challenge. Key applications include lightweight classification models for edge devices, synthetic data generation to augment limited training sets, and investigations into noise robustness, real-time monitoring, and explainable diagnostics. Through a controlled yet realistic acquisition design, the dataset supports the creation of advanced ML-based tools for non-invasive fault identification—enhancing diagnostic accuracy, mitigating insulation risks, and improving safety in critical power infrastructure.

6 June 2023
Verified
Conference Paper
Closed access
MKMichał Kunicki
Michał Kunicki
OKOndřej Kabot
Ondřej Kabot
Michał KoziołMichał Kozioł
Michał Kozioł
This paper presents a complete measurement procedure to detect partial discharge (PD) in instrument transformer under on-site scenario. The objective of this paper is to illustrate how to utilize the commonly available methods to improve the accuracy, reliability and effectiveness of PD diagnostics regarding the high voltage instrument transformers. Three PD measurement methods are used to detect and confirm the defect in the high voltage current transformer (CT) under normal exploitation. In the first step, a directional UHF antenna is used to screen the device under test and to find the possible source of PD signals. In the second step, acoustic sensor is used to confirm the presence of PD in the object pointed in the previous step. These two steps can be performed under normal working conditions of the tested object, as they are completely noninvasive. In the last step, electric method is used to finally confirm the presence of PD and to assess its intensity.

28 April 2026 in Scientific Data
Verified
Journal Article
Open access
PDF file
MKMichal Krátký
Michal Krátký
JFJan Fulneček
Jan Fulneček
LKLukáš Klein
Lukáš Klein
RBRadim Bača
Radim Bača
PCPeter Chovanec
Peter Chovanec
SMStanislav Mišák
Stanislav Mišák
This article introduces a dataset designed for the detection of partial discharges in transmission power lines using covered conductors through a contact galvanic method, sourced from real environments across 23 different power lines in various locations. Though partially introduced in a Kaggle competition (only 3% of data), its full extent is disclosed here for the first time. The dataset is distinguished by its rich, imbalanced distribution across seven classes, derived from signals processed via a sophisticated voltage-based method, and supplemented with extracted features to aid analysis. Its scale, detailed labeling, and real-world basis offer unparalleled opportunities for developing machine learning algorithms aimed at fault detection. This contribution holds vast potential for reuse in electrical engineering research focused on enhancing power distribution network reliability and safety, particularly in the context of predictive maintenance and understanding partial discharge behaviors.

15 May 2024
Verified
Conference Paper
Closed access
APAleksandra Pluzek
Aleksandra Pluzek
LNLukasz Nagi
Lukasz Nagi
MKMichal Koziol
Michal Koziol
OKOndřej Kabot
Ondřej Kabot
The article presents studies on the effect of Al 2 O 3 aluminum oxide on the water content, breakdown voltage, dielectric loss factor tgδ at 90 ̊ C and acid number of the electroinsulating liquid, which in this case is the synthetic ester Midel 7131. It was also investigated what effect the addition of surfactants (oleic acid, ROKwinol 80 and TritonX) to the prepared nanofluids had. All samples were tested in the same way, according to the standards presented in the paper. The motivation to undertake the described research is the noticeable increase in articles on nanofluids and the wide field for the creation of various colloidal liquids, while there are still gaps in the literature describing the mechanisms of influence of nanoparticles on the physicochemical parameters of the base liquids used.