Marcel Ameloot

Prof. Marcel Ameloot

orcid

Research Focus & Metrics

Academic Career Length

39Years (1988-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 September 2019 in Nature Communications
Verified
Journal Article
Open access
PDF file
HBHannelore Bové
Hannelore Bové
EBEva Bongaerts
Eva Bongaerts
ESEli Slenders
Eli Slenders
EBEsmée M. Bijnens
Esmée M. Bijnens
NSNelly D. Saenen
Nelly D. Saenen
TNTim S. Nawrot
Tim S. Nawrot
Particle transfer across the placenta has been suggested but to date, no direct evidence in real-life, human context exists. Here we report the presence of black carbon (BC) particles as part of combustion-derived particulate matter in human placentae using white-light generation under femtosecond pulsed illumination. BC is identified in all screened placentae, with an average (SD) particle count of 0.95 × 104 (0.66 × 104) and 2.09 × 104 (0.9 × 104) particles per mm3 for low and high exposed mothers, respectively. Furthermore, the placental BC load is positively associated with mothers’ residential BC exposure during pregnancy (0.63–2.42 µg per m3). Our finding that BC particles accumulate on the fetal side of the placenta suggests that ambient particulates could be transported towards the fetus and represents a potential mechanism explaining the detrimental health effects of pollution from early life onwards.

1 February 2007 in Analytical Chemistry
Verified
Journal Article
Open access
NBNoël Boens
Noël Boens
WQWenwu Qin
Wenwu Qin
NBNikola Basarić
Nikola Basarić
JHJohan Hofkens
Johan Hofkens
MAMarcel Ameloot
Marcel Ameloot
AMAtsushi Miura
Atsushi Miura
A series of fluorophores with single-exponential fluorescence decays in liquid solution at 20 °C were measured independently by nine laboratories using single-photon timing and multifrequency phase and modulation fluorometry instruments with lasers as excitation source. The dyes that can serve as fluorescence lifetime standards for time-domain and frequency-domain measurements are all commercially available, are photostable under the conditions of the measurements, and are soluble in solvents of spectroscopic quality (methanol, cyclohexane, water). These lifetime standards are anthracene, 9-cyanoanthracene, 9,10-diphenylanthracene, N-methylcarbazole, coumarin 153, erythrosin B, N-acetyl-l-tryptophanamide, 1,4-bis(5-phenyloxazol-2-yl)benzene, 2,5-diphenyloxazole, rhodamine B, rubrene, N-(3-sulfopropyl)acridinium, and 1,4-diphenylbenzene. At 20 °C, the fluorescence lifetimes vary from 89 ps to 31.2 ns, depending on fluorescent dye and solvent, which is a useful range for modern pico- and nanosecond time-domain or mega- to gigahertz frequency-domain instrumentation. The decay times are independent of the excitation and emission wavelengths. Dependent on the structure of the dye and the solvent, the excitation wavelengths used range from 284 to 575 nm, the emission from 330 to 630 nm. These lifetime standards may be used to either calibrate or test the resolution of time- and frequency-domain instrumentation or as reference compounds to eliminate the color effect in photomultiplier tubes. Statistical analyses by means of two-sample charts indicate that there is no laboratory bias in the lifetime determinations. Moreover, statistical tests show that there is an excellent correlation between the lifetimes estimated by the time-domain and frequency-domain fluorometries. Comprehensive tables compiling the results for 20 (fluorescence lifetime standard/solvent) combinations are given.

1 October 2017 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
NSNelly D. Saenen
Nelly D. Saenen
HBHannelore Bové
Hannelore Bové
CSChristian Steuwe
Christian Steuwe
Maarten RoeffaersMaarten Roeffaers
Maarten Roeffaers
EPEline B. Provost
Eline B. Provost
TNTim S. Nawrot
Tim S. Nawrot
Rationale: Ambient air pollution, including black carbon, entails a serious public health risk because of its carcinogenic potential and as climate pollutant. To date, an internal exposure marker for black carbon particles that have cleared from the systemic circulation into the urine does not exist. Objectives: To develop and validate a novel method to measure black carbon particles in a label-free way in urine. Methods: We detected urinary carbon load in 289 children (aged 9–12 yr) using white-light generation under femtosecond pulsed laser illumination. Children’s residential black carbon concentrations were estimated based on a high-resolution spatial temporal interpolation method. Measurements and Main Results: We were able to detect urinary black carbon in all children, with an overall average (SD) of 98.2 × 105 (29.8 × 105) particles/ml. The urinary black carbon load was positively associated with medium-term to chronic (1 mo or more) residential black carbon exposure: +5.33 × 105 particles/ml higher carbon load (95% confidence interval, 1.56 × 105 to 9.10 × 105 particles/ml) for an interquartile range increment in annual residential black carbon exposure. Consistently, children who lived closer to a major road (≤160 m) had higher urinary black carbon load (6.93 × 105 particles/ml; 95% confidence interval, 0.77 × 105 to 13.1 × 105). Conclusions: Urinary black carbon mirrors the accumulation of medium-term to chronic exposure to combustion-related air pollution. This specific biomarker reflects internal systemic black carbon particles cleared from the circulation into the urine, allowing investigators to unravel the complexity of particulate-related health effects.

22 August 2006 in Glia
Verified
Journal Article
Closed access
PDF file
EGEllen Gielen
Ellen Gielen
WBWia Baron
Wia Baron
MVMartin Vandeven
Martin Vandeven
PSPaul Steels
Paul Steels
DHDick Hoekstra
Dick Hoekstra
MAMarcel Ameloot
Marcel Ameloot

22 April 2016 in Nano Letters
Verified
Journal Article
Open access
HBHannelore Bové
Hannelore Bové
CSChristian Steuwe
Christian Steuwe
EFEduard Fron
Eduard Fron
ESEli Slenders
Eli Slenders
JDJan D'haen
Jan D'haen
MAMarcel Ameloot
Marcel Ameloot
Although adverse health effects of carbon black (CB) exposure are generally accepted, a direct, label-free approach for detecting CB particles in fluids and at the cellular level is still lacking. Here, we report nonincandescence related white-light (WL) generation by dry and suspended carbon black particles under illumination with femtosecond (fs) pulsed near-infrared light as a powerful tool for the detection of these carbonaceous materials. This observation is done for four different CB species with diameters ranging from 13 to 500 nm, suggesting this WL emission under fs near-infrared illumination is a general property of CB particles. As the emitted radiation spreads over the whole visible spectrum, detection is straightforward and flexible. The unique property of the described WL emission allows optical detection and unequivocal localization of CB particles in fluids and in cellular environments while simultaneously colocalizing different cellular components using various specific fluorophores as shown here using human lung fibroblasts. The experiments are performed on a typical multiphoton laser-scanning microscopy platform, widely available in research laboratories.

4 March 2009 in Langmuir
Verified
Journal Article
Open access
EGEllen Gielen
Ellen Gielen
NSNick Smisdom
Nick Smisdom
MVMartin Vandeven
Martin Vandeven
BCBen De Clercq
Ben De Clercq
EGEnrico Gratton
Enrico Gratton
MAMarcel Ameloot
Marcel Ameloot
The heterogeneity in composition and interaction within the cellular membrane translates into a wide range of diffusion coefficients of its constituents. Therefore, several complementary microfluorimetric techniques such as fluorescence correlation spectroscopy (FCS), fluorescence recovery after photobleaching (FRAP) and single-particle tracking (SPT) have to be applied to explore the dynamics of membrane components. The recently introduced raster image correlation spectroscopy (RICS) offers a much wider dynamic range than each of these methods separately and allows for spatial mapping of the dynamic properties. RICS is implemented on a confocal laser-scanning microscope (CLSM), and the wide dynamic range is achieved by exploiting the inherent time information carried by the scanning laser beam in the generation of the confocal images. The original introduction of RICS used two-photon excitation and photon counting detection. However, most CLSM systems are based on one-photon excitation with analog detection. Here we report on the performance of such a commercial CLSM (Zeiss LSM 510 META) in the study of the diffusion of the fluorescent lipid analog 1,1′-dioctadecyl-3,3,3′,3′-tetramethyl-indodicarbocyanine perchlorate (DiI-C18(5)) both in giant unilamellar vesicles and in the plasma membrane of living oligodendrocytes, i.e., the myelin-producing cells of the central nervous system. It is shown that RICS on a commercial CLSM with analog detection allows for reliable results in the study of membrane diffusion by removal of unwanted correlations introduced by the analog detection system. The results obtained compare well with those collected by FRAP and FCS.