Ming-Li Ye

Dr. Ming-Li Ye


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020 in Journal of Chromatography A
Verified
Journal Article
Closed access
YZYun Zhang
Yun Zhang
YZYong-Gang Zhao
Yong-Gang Zhao
Muhammad NadeemMuhammad Nadeem
Muhammad Nadeem
MYMing-Li Ye
Ming-Li Ye
Yan ZhuYan Zhu
Yan Zhu

24 June 2019 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
FWFangfang Wu
Fangfang Wu
QCQing-Yin Chen
Qing-Yin Chen
XMXiu-Juan Ma
Xiu-Juan Ma
TLTing-Ting Li
Ting-Ting Li
LWLi-Feng Wang
Li-Feng Wang
Yan ZhuYan Zhu
Yan Zhu
A novel N-doped magnetic covalent organic framework (N-Mag-COF) has been synthesized. It has been evaluated in the magnetic dispersive solid phase extraction (Mag-dSPE) procedure for textiles of fall protection equipment prior to the analysis of allergenic disperse dyes by liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS). Compared with the matrix dilution procedure, much higher sensitivity of the analytical method has been achieved by the N-Mag-COF Mag-dSPE procedure. Furthermore, under the optimum conditions, the level of matrix effects can be dramatically reduced by the N-Mag-COF Mag-dSPE procedure with satisfactory recoveries in the range of 72.2–107%. The precision of the developed method was satisfactory, with relative standard deviations (RSDs) ranging from 2.3% to 7.1%. The limits of detection (LODs) and limits of quantification (LOQs) of 19 allergenic disperse dyes were in the range of 0.021–0.58 μg kg−1 and 0.069–1.91 μg kg−1, respectively. The developed analytical method was successfully applied to the analysis of 20 textile samples of fall protection equipment, in which disperse yellow 39 was found in two samples with concentrations at 0.081 μg kg−1 and 0.062 μg kg−1, respectively. The developed method can be applied to routine analyses for the determination of 19 allergenic disperse dyes in textiles of fall protection equipment.

6 June 2019 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
SHShi-Wei He
Shi-Wei He
YZYun Zhang
Yun Zhang
YZYong-Gang Zhao
Yong-Gang Zhao
MYMing-Li Ye
Ming-Li Ye
Yan ZhuYan Zhu
Yan Zhu
A novel ionic liquid coupled with nano-titania coated modified magnetic GO composites (IL-Ti-Mag-GO) has been synthesized. It has been evaluated in an on-line pass-through cleanup procedure for human plasma prior to the analysis of aconitum alkaloids, i.e., mesaconitine, hypaconitine and aconitine, by liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS). Under optimum conditions, the level of matrix effects can be dramatically reduced by the IL-Ti-Mag-GO on-line pass-through cleanup procedure, with satisfactory recoveries ranging from 81.2% to 108%. The trueness and precision of the developed method were satisfactory, with relative errors (REs) less than 19% and within- and between-run RSDs less than 7.0%. The limits of detection (LODs) and limits of quantification (LOQs) for aconitum alkaloids were in the range of 0.01–0.028 μg L−1 and 0.034–0.092 μg L−1, respectively. The developed analytical method has been successfully applied to the analysis of mesaconitine, hypaconitine and aconitine in two cases of suspected aconite poisoning, and the concentration of aconitine and hypaconitine in one sample was determined to be 0.076 μg L−1 and 0.069 μg L−1, respectively. The results demonstrate the applicability of the developed analytical method to clinical studies.

5 January 2021 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
PDF file
HLHaihong Li
Haihong Li
MYMing-Li Ye
Ming-Li Ye
FWFangfang Wu
Fangfang Wu
XZXuyang Zhao
Xuyang Zhao
LWLifeng Wang
Lifeng Wang
HCHai-Rong Cui
Hai-Rong Cui
An analysis method was established to determine 14 organophosphorus ester (OPE) flame retardants in fall protection equipment by combining accelerated solvent extraction (ASE) and solid-phase extraction (SPE) with high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The ASE parameters were optimized as follows: static extraction with acetonitrile at 80°C for 5 min for two cycles. The combined extract was purified with the ENVI-18 cartridge before further analysis. A HILIC column was used to separate the OPEs using an acetonitrile/water mixture as the mobile phase with the detection by the electrospray ionization mass spectrometry, which was operated under the positive mode. Under optimized conditions, the limit of detection for the target OPEs ranged in 0.015–1.33 ng/g, with a spike recovery of 71.6%–114% and a relative standard deviation of 0.8%–11.2%. The developed method was used to analyze OPEs in fall protection equipment (safety helmets and ropes), where OPEs were all detectable. Safety ropes displayed a higher concentration of OPEs than ones in safety helmets, with the pollutants being mainly triphenyl phosphate, 2-ethylhexyl diphenyl phosphate (EHDPP), tri(2-ethylhexyl) phosphate, and tri-n-butyl phosphate in the range of 11.07 ng/g‒815.53 ng/g. The EHDPP was the dominant compound in safety helmets with the concentration from 26.84 to 95.29 ng/g, while the other OPEs in safety helmets were lower than 5.136 ng/g. The potential health and environmental risks of these fall protection equipment during their use and disposal call for further attention.

16 June 2021 in Chemical Papers
Verified
Journal Article
Closed access
PDF file
ZSZhen-Hua Sheng
Zhen-Hua Sheng
PZPing-Ping Zhan
Ping-Ping Zhan
MYMing-Li Ye
Ming-Li Ye
YLYin Lu
Yin Lu
YZYun Zhang
Yun Zhang
Yong-Gang ZhaoYong-Gang Zhao
Yong-Gang Zhao

13 October 2026 in Advanced Functional Materials
Verified
Journal Article
Closed access
XGXiaoling Gu
Xiaoling Gu
MYMing-Li Ye
Ming-Li Ye
HNHongyun Niu
Hongyun Niu
YSYali Shi
Yali Shi
BCBan Cao
Ban Cao
YCYaqi Cai
Yaqi Cai