Qinghai Xie

Dr. Qinghai Xie

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Fire Safety Journal
Verified
Journal Article
Closed access
Zhen-Hua DuanZhen-Hua Duan
Zhen-Hua Duan
QXQinghai Xie
Qinghai Xie
WXWengang Xie
Wengang Xie

1 July 2016 in Fire Safety Journal
Verified
Journal Article
Closed access
Zhen-Hua DuanZhen-Hua Duan
Zhen-Hua Duan
ZLZhiwei Li
Zhiwei Li
QXQinghai Xie
Qinghai Xie
LSLuming Shen
Luming Shen

19 March 2016 in Fire Technology
Verified
Journal Article
Closed access
PDF file
Zhen-Hua DuanZhen-Hua Duan
Zhen-Hua Duan
QXQinghai Xie
Qinghai Xie
ZLZhiwei Li
Zhiwei Li
WWWan Wang
Wan Wang

24 February 2024 in Construction and Building Materials
Verified
Journal Article
Closed access
XZXiaoqing Zhao
Xiaoqing Zhao
TYTianfeng Yang
Tianfeng Yang
Zhen-Hua DuanZhen-Hua Duan
Zhen-Hua Duan
QXQinghai Xie
Qinghai Xie
ZZZhongling Zong
Zhongling Zong
ZYZhilong Yu
Zhilong Yu

19 April 2018 in Fire Technology
Verified
Journal Article
Closed access
PDF file
QXQinghai Xie
Qinghai Xie
Zhen-Hua DuanZhen-Hua Duan
Zhen-Hua Duan
PGPaolo Gardoni
Paolo Gardoni
KHKexu Hu
Kexu Hu

1 May 2016 in Structural Engineering International
Verified
Journal Article
Closed access
Zhen-Hua DuanZhen-Hua Duan
Zhen-Hua Duan
KZKaijian Zhang
Kaijian Zhang
QXQinghai Xie
Qinghai Xie
Concrete made of recycled coarse aggregate (RCA) derived from multiple sources can have relative variation in mechanical properties compared with natural aggregate concrete (NAC), resulting in a lower reliability of a recycled aggregate concrete (RAC) beam than that of NAC beam. In this paper, a method is proposed to improve the reliability of beams made with RAC by increasing the reinforcement ratio. According to the equilibrium equations of beams subjected to bending moment, the increase in reinforcement ratio can be achieved by decreasing the RAC design strength. Same mean compressive strengths are assumed for RAC and NAC and four factors are considered including concrete grade, reinforcement grade, reinforcement ratio and the ratio of external loads in reliability analysis. Using NAC beams as a reference and keeping the target reliability index the same as that of RAC beams, the analysis results show that RAC design strength decreases with increase in coefficient of variation (CoV) of RAC compressive strength. When the CoV of RAC compressive strength is 20%, the RAC design strengths are 0.93 and 0.90 times of the NAC design strength with a 95% confidence level for grade C30 and C40 concrete, respectively.