The modification of electrodes using carbon-based nanomaterials is an efficient strategy for enhancing their electrical conductivity and working surface area. In this study, we explore the ability of a screen-printed carbon electrode (SPCE) modified with graphene-cyclodextrin/ferrocenyl-carnosine (GCD/FcCAR) supramolecular assembly for the determination of Mn(II) in an aqueous solution. Although Mn(II) is an essential nutrient for humans, it can be toxic at elevated levels, leading to neurotoxic symptoms. Consequently, accurate analytical determination is necessary. The graphene platform (G-Alk) was derivatized with mono-6-deoxy-6-azido-β-cyclodextrin (CD) via a click chemistry reaction. The chemical–physical properties of the GCD system were investigated using thermogravimetric analysis, scanning electron microscopy, Raman spectroscopy, and X-ray photoelectron spectroscopy. An aliquot of GCD dispersion was cast on the surface of the SPCE (SPCE/GCD), and its electrochemical response was evaluated using cyclic voltammetry (CV) with [Fe(CN)6]3− as the redox probe. A notable 30% increase in the signal was observed for SPCE/GCD compared with the bare SPCE. Additionally, the remarkable metal-ion complexing and electroanalytical abilities of FcCAR were leveraged in this study. Therefore, CV and differential pulse voltammetry (DPV) experiments were conducted to assess the voltammetric response of FcCAR on SPCE/GCD (SPCE/GCD/FcCAR) toward Mn(II). DPV measurements allowed us to obtain a limit of detection (LOD) and limit of quantification (LOQ) of 0.69 and 2.3 nmol L−1, respectively, within a linear concentration range (0.17 ≤ [Mn(II)]/nmol L−1 ≤ 48). The LOD obtained is one of the lowest reported in the literature, highlighting the potential applicability of the SPCE/GCD/FcCAR system for Mn(II) determination in aqueous solutions.
The integration of molecular imprinting technology with electrochemical methods has become fundamental in the development of next-generation sensors. This study explores two different strategies for developing a dopamine-based molecularly imprinted polymer (MIP) for the electrochemical sensing of levofloxacin. In the first case, the MIP is developed by electropolymerization on a screen-printed carbon electrode (SPCE) surface using cyclic voltammetry, while in the second, the MIP is obtained by an oxidation process, and the resulting dispersion is drop-cast on the SPCE surface. The same approach is used for a non-imprinted polymer. The physicochemical properties of the synthesized materials and the surface morphology of the modified electrodes are investigated by several techniques. Differential pulse voltammetry is used to evaluate the performance of the modified electrodes, assessing their linear concentration range, limit of detection, and limit of quantification, together with repeatability and selectivity. MIP-based SPCEs obtained with these two fabrication strategies exhibited comparable imprinting factor values and linear concentration ranges, along with comparable limits of detection and quantification. The MIP-based SPCE obtained by electropolymerization showed greater repeatability, whereas the MIP-based SPCE produced by drop-casting provided higher sensitivity in levofloxacin detection.
An extensive study on the interactions between O-phosphorylethanolamine (PEA) and O-phosphorylcholine (PPC), Cu2+ and Zn2+, is thoroughly described. The formation constants were determined at different temperatures (15 ≤ t/°C ≤ 37) and ionic strengths (0.15 ≤ I/mol L−1 ≤ 0.97) by potentiometric titrations. For the Zn2+-PEA/-PPC systems, speciation models were also confirmed by 1H NMR titrations at t = 25 °C and I = 0.15 mol L−1 in NaCl. Sequestering abilities were calculated under different temperatures and physiological conditions. Density Functional Theory (DFT) calculations along with enhanced sampling of the conformational space were performed aimed to better elucidate the Cu2+-, Zn2+- PEA/PPC molecular interactions and their relative stabilities. Overall, both experiments and computer simulations showed that the complex species involved in the Cu2+–PEA system exhibited a significant and selective stability, particularly in conditions simulating cerebrospinal fluid. While the binding molecular mechanisms were elucidated via DFT supplemented by automized conformational search, the computational binding energies trend qualitatively follows the experimental logK behavior across the Cu2+-, Zn2+- PEA/PPC complexes. These results highlight the potential physiological role of PEA in modulating free copper levels and regulating its redox activity in pathological conditions, such as Wilson’s Disease (WD).
Metronidazole (MTZ) is a widely used nitroimidazole antibiotic, and its persistence has raised growing concerns as an emerging environmental contaminant. This study focuses on the design of an electrochemical sensor based on Molecularly Imprinted Polymers (MIPs) for its detection, by a synergistic computational-experimental strategy. A hierarchical computational framework combining conformational sampling, density functional theory and finite-temperature condensed-phase ab initio molecular dynamics was employed to evaluate aniline (ANL) and dopamine (DA) as candidate monomers. Static calculations provided a preliminary screening based on monomer-template complex stability, while molecular dynamics simulations assessed the dynamic balance between potential template affinity and reversibility. Although DA exhibited more persistent hydrogen-bonding and aromatic interactions, ANL showed a more favourable interaction profile, promoting efficient MTZ removal and accessible recognition cavities. These findings support the selection of ANL as the optimal functional monomer. The ANL-based MIP was therefore electropolymerized on screen-printed carbon electrodes (SPCEs) via cyclic voltammetry (CV) and characterized via differential pulse voltammetry (DPV) using K3Fe(CN)6, yielding an imprinting factor (IF) of 2.6, a linear response in the range of 27−129 nmol L−1, a sensitivity of 26.01 A L mol−1, and limits of detection and quantification of 6.7 and 22.3 nmol L−1, respectively. The sensor also showed good repeatability, reproducibility, and negligible interference from other antibiotics. Its superior analytical performance relative to the corresponding DA-based MIP experimentally confirms the computational prediction. These findings demonstrate that combining atomistic pre-screening with targeted experimental validation can reduce empirical trial-and-error and accelerate the rational development of selective MIP-based sensors.