Yanling Wang

Dr. Yanling Wang


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2020 in Processes
Verified
Journal Article
Open access
PDF file
PZPei Zhang
Pei Zhang
YWYanling Wang
Yanling Wang
LLLikai Liang
Likai Liang
XLXing Li
Xing Li
QDQingtian Duan
Qingtian Duan
Accurately predicting wind power plays a vital part in site selection, large-scale grid connection, and the safe and efficient operation of wind power generation equipment. In the stage of data pre-processing, density-based spatial clustering of applications with noise (DBSCAN) algorithm is used to identify the outliers in the wind power data and the collected wind speed data of a wind power plant in Shandong Province, and the linear regression method is used to correct the outliers to improve the prediction accuracy. Considering the important impact of wind speed on power, the average value, the maximum difference and the average change rate of daily wind speed of each historical day are used as the selection criteria to select similar days by using DBSCAN algorithm and Euclidean distance. The short-term wind power prediction is carried out by using the similar day data pre-processed and unprocessed, respectively, as the input of back propagation neural network optimized by genetic algorithm (GA-BP neural network). Analysis of the results proves the practicability and efficiency of the prediction model and the important role of outlier identification and correction in improving the accuracy of wind power prediction.

9 April 2011 in Theoretical Chemistry Accounts
Verified
Journal Article
Closed access
PDF file
YWYanling Wang
Yanling Wang
QPQiang Peng
Qiang Peng
QHQiufei Hou
Qiufei Hou
KZKun Zhao
Kun Zhao
YLYing Liang
Ying Liang
BLBenlin Li
Benlin Li

23 April 2021 in Space Weather
Verified
Journal Article
Open access
PDF file
HWHan Wang
Han Wang
ZXZanyang Xing
Zanyang Xing
NBNanan Balan
Nanan Balan
YWYanling Wang
Yanling Wang
QZQ.-H. Zhang
Q.-H. Zhang
LLLi‐Kai Liang
Li‐Kai Liang
Geomagnetically induced current (GIC) in utility systems such as electric power grids occurring during extreme geomagnetic storms can exceed the tolerance limit of the systems, which can cause serious system damages. It has therefore been important to evaluate the GIC levels in the utility systems. This study presents the simulation and analysis of GIC levels in the Shandong 500 kV power grid system consisting of 34 substations under a variety of uniform induced geoelectric fields. The line type, substation grounding resistance, and other influencing factors are included in the simulations. The results show that the GIC level varies largely in the 34 substations. In 11 substations, the GIC exceeds 100 A and it reaches up to ∼200 A in two substations for an assumed 1 V/km induced electric field. The changes in the GIC distribution are found consistent with the direction changes of the electric field. Utilizing the directional sensitivity, we calculate the maximum GIC level for the optimum direction for all substations. By combining this information with statistical tools, we propose a method for identifying the key substations which are most vulnerable. The result can provide suggestions for GIC disaster prevention and mitigation, substation site selection, monitoring equipment installation, and so on, in Shandong province.

27 March 2018 in Energies
Verified
Journal Article
Open access
PDF file
YWYanling Wang
Yanling Wang
YMYang Mo
Yang Mo
MWMingqiang Wang
Mingqiang Wang
XZXiaofeng Zhou
Xiaofeng Zhou
LLLikai Liang
Likai Liang
PZPei Zhang
Pei Zhang
The conductor temperature of an overhead transmission line varies with time and space, which has an important impact on the system operation. In this paper, the conductor temperature is solved iteratively by the CIGRE heat balance equation. The time–space variation of conductor temperature of a 220-kV transmission line is analyzed using real meteorological data from Weihai. Considering the temporal distribution characteristics, the seasonal model of the conductor temperature is given. Considering the spatial distribution, the mean value model, the weight average model, and the segmentation model are established. The system power flow involving the conductor temperature is established based on the relationship between conductor temperature and transmission line parameters. Through the calculation of power flow and the analysis of the maximum power transmission capability, the accuracy of the segmentation model is verified. The results show that the conductor temperature of overhead lines has obvious time–space variation characteristics. It is necessary to consider the time–space variation when analyzing the operation state of power systems.

27 February 2019 in Energies
Verified
Journal Article
Open access
PDF file
FSFan Song
Fan Song
YWYanling Wang
Yanling Wang
HYHongbo Yan
Hongbo Yan
XZXiaofeng Zhou
Xiaofeng Zhou
ZNZhiqiang Niu
Zhiqiang Niu
The power grid is under pressure to maintain a reliable supply because of constrained budgets and environmental policies. In order to effectively make use of existing transmission lines, it is important to accurately evaluate the line capacity. Dynamic thermal rating (DTR) offers a way to increase the utilization of capacity under real-time meteorological data. However, DTR relies on a number of sensors and the cost is high. Therefore, a method of improving the utilization of capacity by quasi-dynamic thermal rating (QDR) is proposed in this paper. QDR at different confidence levels and time scales is determined through the statistical analysis of line ampacity driven by key parameters, and the key parameters is identified by control variate method. In addition, the operation risk and tension loss is evaluated. The results show that QDR can increase the utilization of line capacity and in the absence of along-line measuring devices, QDR is more accurate, reliable and cost-saving. The managers can determine the appropriate confidence level according to the operation risk and tension loss that the system can bear, and shorten the time scale with the permission of the operation and control complexity.

1 January 2017 in Journal of Information Processing Systems
Verified
Journal Article
Closed access
ZYZhijie Yan
Zhijie Yan
YWYanling Wang
Yanling Wang
LLLikai Liang
Likai Liang
Journal of Information Processing Systems