We developed a novel method to accelerate diffusion spectrum imaging using compressed sensing. The method can be applied to either reduce acquisition time of diffusion spectrum imaging acquisition without losing critical information or to improve the resolution in diffusion space without increasing scan time. Unlike parallel imaging, compressed sensing can be applied to reconstruct a sub‐Nyquist sampled dataset in domains other than the spatial one. Simulations of fiber crossings in 2D and 3D were performed to systematically evaluate the effect of compressed sensing reconstruction with different types of undersampling patterns (random, gaussian, Poisson disk) and different acceleration factors on radial and axial diffusion information. Experiments in brains of healthy volunteers were performed, where diffusion space was undersampled with different sampling patterns and reconstructed using compressed sensing. Essential information on diffusion properties, such as orientation distribution function, diffusion coefficient, and kurtosis is preserved up to an acceleration factor of R = 4. Magn Reson Med, 2011.
30 October 2017 in Journal of Magnetic Resonance Imaging
Purpose: To provide an improved correction for gradient nonlinearity (GN) effects in diffusion‐weighted imaging (DWI). These effects produce spatially varying apparent diffusion coefficient (ADC), a result that will be significant in large field‐of‐view imaging, and may be confounded by distortion and concomitant fields related to the DWI acquisition.Materials and Methods: The effect of more accurate gradient field maps on GN correction (GNC) of ADC was evaluated. A simulation compared GN effects in commonly imaged anatomy. A temperature‐controlled phantom was imaged at positions 0 cm and 11 cm from isocenter and in two whole‐body MRI systems at 1.5T with different patient bore diameters (55 cm and 60 cm). Varying correction methods were applied to determine the errors from spatial variance and interscanner reproducibility.Results: As compared to conventional fifth‐order spherical harmonics, a seventh‐order GNC improved ADC accuracy by 1%. The combination of GNC with a dual‐spin‐echo pulse sequence and a retrospective concomitant field correction reduced ADC error due to spatial variance from 9.5% to 1.8% (55 cm bore) and from 4.2% to 1.8% (60 cm bore). The error in ADC attributed to interscanner reproducibility was reduced from 5.8% to 0.15% (at isocenter) and from 10% to 0.63% (11 cm from isocenter).Conclusion: GNC in DWI improved spatial accuracy and interscanner reproducibility of ADC. J. Magn. Reson. Imaging 2013;38:448–453.