Daily-life conversation relies on speech perception in quiet and noise. Because of the COVID-19 pandemic, face masks have become mandatory in many situations. Acoustic attenuation of sound pressure by the mask tissue reduces speech perception ability, especially in noisy situations. Masks also can impede the process of speech comprehension by concealing the movements of the mouth, interfering with lip reading. In this prospective observational, cross-sectional study including 17 participants with normal hearing, we measured the influence of acoustic attenuation caused by medical face masks (mouth and nose protection) according to EN 14683 and of N95 masks according to EN 1149 (EN 14683) on the speech recognition threshold and listening effort in various types of background noise. Averaged over all noise signals, a surgical mask significantly reduced the speech perception threshold in noise was by 1.6 dB (95% confidence interval [CI], 1.0, 2.1) and an N95 mask reduced it significantly by 2.7 dB (95% CI, 2.2, 3.2). Use of a surgical mask did not significantly increase the 50% listening effort signal-to-noise ratio (increase of 0.58 dB; 95% CI, 0.4, 1.5), but use of an N95 mask did so significantly, by 2.2 dB (95% CI, 1.2, 3.1). In acoustic measures, mask tissue reduced amplitudes by up to 8 dB at frequencies above 1 kHz, whereas no reduction was observed below 1 kHz. We conclude that face masks reduce speech perception and increase listening effort in different noise signals. Together with additional interference because of impeded lip reading, the compound effect of face masks could have a relevant impact on daily life communication even in those with normal hearing.
26 November 2014 in European Archives of Oto-Rhino-Laryngology
Certain patients with conductive or mixed hearing loss can benefit from bone-conduction hearing devices or active middle ear implants. Available devices differ in coupling site, energy transfer from the sound processor to the implant, and the active or passive actuator technology. The audiological benefit of those devices depends on the maximum stable power output and the noise floor of the device, the degree and expected stability of the sensorineural hearing loss and the coupling efficiency with the aim on achieving a minumum of 30-35 dB effective dynamic range. The choice of the device is often a trade-off between the optimal audiological solution with respect to the hearing loss, technical device-related parameters and the expected coupling efficiency, the optimal surgical solution with respect to patho-anatomical aspects, device dimensions and the coupling site, invasiveness or surgical risks, and other patient factors with respect to the patients' wish and expectations, social aspects, device usability and connectivity. This review article lists all currently available implantable and conventional bone-conduction hearing devices and active middle ear implants with respect to technical features like maximum power output, market availability, and the expected effective output dynamic range.