Jens Rieger

Mr. Jens Rieger


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2013 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
TMThilo Michel
Thilo Michel
JRJens Rieger
Jens Rieger
GAGisela Anton
Gisela Anton
FBFlorian Bayer
Florian Bayer
MBMatthias W Beckmann
Matthias W Beckmann
AZAndrea Zang
Andrea Zang
We show that a distribution of micrometer-sized calcifications in the human breast which are not visible in clinical x-ray mammography at diagnostic dose levels can produce a significant dark-field signal in a grating-based x-ray phase-contrast imaging setup with a tungsten anode x-ray tube operated at 40 kVp. A breast specimen with invasive ductal carcinoma was investigated immediately after surgery by Talbot-Lau x-ray interferometry with a design energy of 25 keV. The sample contained two tumors which were visible in ultrasound and contrast-agent enhanced MRI but invisible in clinical x-ray mammography, in specimen radiography and in the attenuation images obtained with the Talbot-Lau interferometer. One of the tumors produced significant dark-field contrast with an exposure of 0.85 mGy air-kerma. Staining of histological slices revealed sparsely distributed grains of calcium phosphate with sizes varying between 1 and 40 μm in the region of this tumor. By combining the histological investigations with an x-ray wave-field simulation we demonstrate that a corresponding distribution of grains of calcium phosphate in the form of hydroxylapatite has the ability to produce a dark-field signal which would-to a substantial degree-explain the measured dark-field image. Thus we have found the appearance of new information (compared to attenuation and differential phase images) in the dark-field image. The second tumor in the same sample did not contain a significant fraction of these very fine calcification grains and was invisible in the dark-field image. We conclude that some tumors which are invisible in x-ray absorption mammography might be detected in the x-ray dark-field image at tolerable dose levels.

1 September 2013 in Zeitschrift für Medizinische Physik
Verified
Journal Article
Open access
GAGisela Anton
Gisela Anton
FBFlorian Bayer
Florian Bayer
MBMatthias W. Beckmann
Matthias W. Beckmann
JDJürgen Durst
Jürgen Durst
PFPeter A. Fasching
Peter A. Fasching
LWLukas Wucherer
Lukas Wucherer
Mastectomy specimens were investigated using a Talbot-Lau X-ray imaging set-up. Significant structures in the darkfield were observed, which revealed considerably higher contrast than those observed in digital mammography. Comparison with the histomorphometric image proofs that the darkfield signal correlates with a tumor region containing small calcification grains of 3 to 30μm size.

10 May 2016 in Medical Physics
Verified
Journal Article
Closed access
GPGeorg Pelzer
Georg Pelzer
GAGisela Anton
Gisela Anton
FHFlorian Horn
Florian Horn
JRJens Rieger
Jens Rieger
ARAndré Ritter
André Ritter
TMThilo Michel
Thilo Michel

16 September 2014 in Optics Express
Verified
Journal Article
Closed access
PDF file
ARAndré Ritter
André Ritter
PBPeter Bartl
Peter Bartl
FBFlorian Bayer
Florian Bayer
KGKarl C. Gödel
Karl C. Gödel
WHWilhelm Haas
Wilhelm Haas
GAGisela Anton
Gisela Anton
A simulation framework for coherent X-ray imaging, based on scalar diffraction theory, is presented. It contains a core C++ library and an additional Python interface. A workflow is presented to include contributions of inelastic scattering obtained with Monte-Carlo methods. X-ray Talbot-Lau interferometry is the primary focus of the framework. Simulations are in agreement with measurements obtained with such an interferometer. Especially, the dark-field signal of densely packed PMMA microspheres is predicted. A realistic modeling of the microsphere distribution, which is necessary for correct results, is presented. The framework can be used for both setup design and optimization but also to test and improve reconstruction methods.

5 September 2017 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
SKSebastian Kaeppler
Sebastian Kaeppler
JRJens Rieger
Jens Rieger
GPGeorg Pelzer
Georg Pelzer
FHFlorian Horn
Florian Horn
TMThilo Michel
Thilo Michel
CRChristian Riess
Christian Riess
Grating-based Talbot–Lau x-ray interferometry is a popular method for measuring absorption, phase shift, and small-angle scattering. The standard acquisition method for this modality is phase stepping, where the Talbot pattern is reconstructed from multiple images acquired at different grating positions. We review the implicit assumptions in phase-stepping reconstruction, and find that the assumptions of perfectly known grating positions and homoscedastic noise variance are violated in some scenarios. Additionally, we investigate a recently reported estimation bias in the visibility and dark-field signal. To adapt the phase-stepping reconstruction to these findings, we propose three improvements to the reconstruction. These improvements are (a) to use prior knowledge to compute more accurate grating positions to reduce moiré artifacts, (b) to utilize noise variance information to reduce dark-field and phase noise in high-visibility acquisitions, and (c) to perform correction of an estimation bias in the interferometer visibility, leading to more quantitative dark-field imaging in acquisitions with a low signal-to-noise ratio. We demonstrate the benefit of our methods on simulated data, as well as on images acquired with a Talbot–Lau interferometer.

16 August 2013 in Optics Express
Verified
Journal Article
Open access
PDF file
FBFlorian Bayer
Florian Bayer
SZSimon Zabler
Simon Zabler
CBChristian Brendel
Christian Brendel
GPGeorg Pelzer
Georg Pelzer
JRJens Rieger
Jens Rieger
GAGisela Anton
Gisela Anton
Over the recent years X-ray differential phase-contrast imaging was developed for the hard X-ray regime as produced from laboratory X-ray sources. The technique uses a grating-based Talbot-Lau interferometer and was shown to yield image contrast gain, which makes it very interesting to the fields of medical imaging and non-destructive testing, respectively. In addition to X-ray attenuation contrast, the differential phase-contrast and dark-field images provide different structural information about a specimen. For the dark-field even at length scales much smaller than the spatial resolution of the imaging system. Physical interpretation of the dark-field information as present in radiographic and tomographic (CT) images requires a detailed look onto the geometric orientation between specimen and the setup. During phase-stepping the drop in intensity modulation, due to local scattering effects within the specimen is reproduced in the dark-field signal. This signal shows strong dependencies on micro-porosity and micro-fibers if these are numerous enough in the object. Since a grating-interferometer using a common unidirectional line grating is sensitive to X-ray scattering in one plane only, the dark-field image is influenced by the fiber orientations with respect to the grating bars, which can be exploited to obtain anisotropic structural information. With this contribution, we attempt to extend existing models for 2D projections to 3D data by analyzing dark-field contrast tomography of anisotropically structured materials such as carbon fiber reinforced carbon (CFRC).