aravind nehrujee

Dr. aravind nehrujee


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2021 in IEEE Access
Verified
Journal Article
Open access
ANaravind nehrujee
aravind nehrujee
HAHallel Andrew
Hallel Andrew
REReethajanetsurekha
Reethajanetsurekha
APAnn Patricia
Ann Patricia
SSSelvaraj Samuelkamaleshkumar
Selvaraj Samuelkamaleshkumar
SBSivakumar Balasubramanian
Sivakumar Balasubramanian
Hand neurorehabilitation involves training movements at the forearm, wrist, fingers, and thumb joints. Assisted training of all these joints requires either one complex multiple degree-of-freedom (DOF) robot or a set of simple robots with one or two DOF. Neither of these is economic or clinically viable. This paper addresses this problem with the PLU g and train r O bot (PLUTO)- a single DOF robot that can train multiple joints one at a time. PLUTO has a single actuator with a set of passive attachments/mechanisms that can be easily attached/detached to train for wrist flexion-extension, wrist ulnar-radial deviation, forearm pronation-supination, and gross hand opening-closing. The robot can provide training in active and assisted regimes. PLUTO is linked to performance adaptive computer games to provide feedback to the patients and motivate them during training. As the first step towards clinical validation, the device usability was evaluated by 45 potential stakeholders/end-users of the device, including 15 patients, 15 caregivers, and 15 clinicians with standardized questionnaires: System Usability Scale (SUS) and User Experience Questionnaire (UEQ). Patients and caregivers were administered the questionnaire after a two-session training with the robot. Clinicians, on the other hand, had a single session demo, after which feedback was obtained. The total SUS score obtained from patients, clinicians, and caregivers was 73.3 ± 14.6 (n = 45), indicating good usability. The UEQ score was rated positively in all subscales by both patients and clinicians, indicating that the features of PLUTO match their expectations. The positive response from the preliminary testing and the feedback from the stakeholders indicate that with additional passive mechanisms, assessment features, and optimized ergonomics, PLUTO will be a versatile, affordable, and useful system for hand rehabilitation.

7 November 2023 in Robotics
Verified
Journal Article
Open access
PDF file
PJPrem Kumar Mathavan Jeyabalan
Prem Kumar Mathavan Jeyabalan
ANaravind nehrujee
aravind nehrujee
SESamuel Elias
Samuel Elias
MKM. Magesh Kumar
M. Magesh Kumar
SSS. Sujatha
S. Sujatha
SBSivakumar Balasubramanian
Sivakumar Balasubramanian
Traditional end-effector robots for arm rehabilitation are usually attached at the hand, primarily focusing on coordinated multi-joint training. Therapy at an individual joint level of the arm for severely impaired stroke survivors is not always possible with existing end-effector robots. The Arm Rehabilitation Robot (AREBO)—an end-effector robot—was designed to provide both single and multi-joint assisted training while retaining the advantages of traditional end-effector robots, such as ease of use, compactness and portability, and potential cost-effectiveness (compared to exoskeletons). This work presents the design, optimization, and characterization of AREBO for training single-joint movements of the arm. AREBO has three actuated and three unactuated degrees of freedom, allowing it to apply forces in any arbitrary direction at its endpoint and self-align to arbitrary orientations within its workspace. AREBO’s link lengths were optimized to maximize its workspace and manipulability. AREBO provides single-joint training in both unassisted and adaptive weight support modes using a human arm model to estimate the human arm’s kinematics and dynamics without using additional sensors. The characterization of the robot’s controller and the algorithm for estimating the human arm parameters were performed using a two degrees of freedom mechatronic model of the human shoulder joint. The results demonstrate that (a) the movements of the human arm can be estimated using a model of the human arm and robot’s kinematics, (b) AREBO has similar transparency to that of existing arm therapy robots in the literature, and (c) the adaptive weight support mode control can adapt to different levels of impairment in the arm. This work demonstrates how an appropriately designed end-effector robot can be used for single-joint training, which can be easily extended to multi-joint training. Future work will focus on the evaluation of the system on patients with any neurological condition requiring arm training.

28 November 2025 in bioRxiv
Verified
Preprint
Open access
NRNeha A. Reddy
Neha A. Reddy
MMMichelle C. Medina
Michelle C. Medina
JNJordan N. Northrop
Jordan N. Northrop
CZChendong Zou
Chendong Zou
RCRebecca Grace Clements
Rebecca Grace Clements
MBMolly G Bright
Molly G Bright
Multi-echo independent component analysis (ME-ICA) has been demonstrated to improve sensitivity and reliability of task functional magnetic resonance imaging (fMRI) data and, in particular, motor-task data with inherent task-correlated head motion. However, previous work has shown that an overly aggressive ME-ICA denoising approach may unintentionally remove task-related signal, while a more conservative approach may not effectively mitigate noise. While the effects of varied implementations of ME-ICA on signal and noise characteristics have been tested thoroughly in breath-hold data, the effects of similar modeling decisions have not been studied in motor-task data, which present with a more localized neural response. Here, we tested and compared the impacts of three analysis methods using rejected ME-ICA components as regressors in subject-level modeling: Aggressive (simple inclusion of ME-ICA regressors), Moderate (excluding task-correlated ME-ICA regressors from the model), and Conservative (orthogonalization of ME-ICA regressors to the core model and accepted ME-ICA components). We applied these methods to data from healthy and multiple sclerosis populations that included performance of hand-grasp, shoulder-abduction, and ankle-flexion tasks. We found that when the amount of head motion and its correlation with the task was high and the expected task-evoked signal was relatively low, the Conservative method led to significantly higher activation, t-statistics, and test-retest similarity in motor regions compared to the Aggressive method. Future motor-task studies may wish to implement similar models to prevent loss of motor signal, while still mitigating the effects of task-correlated head motion.

3 November 2023
Verified
Book Chapter
Closed access
SBSivakumar Balasubramanian
Sivakumar Balasubramanian
ANaravind nehrujee
aravind nehrujee
AAAbha Agrawal
Abha Agrawal
GVGuruprasad V.
Guruprasad V.
SSShovan Saha
Shovan Saha
SSSujatha Srinivasan
Sujatha Srinivasan

4 September 2026 in Aperture Neuro
Verified
Journal Article
Open access
NRNeha A. Reddy
Neha A. Reddy
MMMichelle C. Medina
Michelle C. Medina
JNJordan N. Northrop
Jordan N. Northrop
CZChendong Zou
Chendong Zou
RCRebecca Grace Clements
Rebecca Grace Clements
MBMolly G Bright
Molly G Bright
Multi-echo independent component analysis (ME-ICA) has been demonstrated to improve sensitivity and reliability of task functional magnetic resonance imaging (fMRI) data and, in particular, motor-task data with inherent task-correlated head motion. However, previous work has shown that an overly aggressive ME-ICA denoising approach may unintentionally remove task-related signal, while a more conservative approach may not effectively mitigate noise. While the effects of varied implementations of ME-ICA on signal and noise characteristics have been tested thoroughly in breath-hold data, the effects of similar modeling decisions have not been studied in motor-task data, which present with a more localized neural response. Here, we tested and compared the impacts of three analysis methods using rejected ME-ICA components as regressors in subject-level modeling: Aggressive (simple inclusion of ME-ICA regressors), Moderate (excluding task-correlated ME-ICA regressors from the model), and Conservative (orthogonalization of ME-ICA regressors to the core model and accepted ME-ICA components). We applied these methods to data from healthy and multiple sclerosis populations that included performance of hand-grasp, shoulder-abduction, and ankle-flexion tasks. We found that when the amount of head motion and its correlation with the task was high and the expected task-evoked signal was relatively low, the Conservative method led to significantly higher activation, t-statistics, and test-retest similarity in motor regions compared to the Aggressive method. Future motor-task studies may wish to implement similar models to prevent loss of motor signal, while still mitigating the effects of task-correlated head motion.

2 November 2026 in medRxiv
Verified
Preprint
Open access
HJHannah R Johnson
Hannah R Johnson
CZChendong Zou
Chendong Zou
RTRamyar Taha
Ramyar Taha
JNJordan N Northrop
Jordan N Northrop
NRNeha A Reddy
Neha A Reddy
MBMolly G Bright
Molly G Bright
Acute intermittent hypoxia (AIH) therapy is a promising neurorehabilitative intervention with well- documented improvement in motor function in people with spinal cord injury. Its effect on lower-limb motor control in multiple sclerosis (MS), where walking impairment is a leading source of disability, remain uncharacterized, and the supraspinal effects of AIH therapy are unknown. In a sham-controlled, double-blind crossover trial ( NCT05164705 ), 23 adults with MS completed 5 sessions of AIH therapy and of sham therapy; magnetic resonance imaging (MRI) was performed before and after each therapeutic intervention. At each timepoint, blood oxygenation level-dependent (BOLD) functional MRI was collected during a repeated plantar- and dorsi-flexion task. Task-evoked activation was modeled at the group level and compared across timepoint and therapeutic arm. Activation changes differed for the left- and right-foot task. AIH augmented activation in the basal ganglia, thalamus, and cortical motor regions during left-foot movement with similar but sub-threshold patterns for the right foot. Right-foot movement additionally showed enhanced deactivation in prefrontal, parietal, and temporal cortices, although these effects were primarily in white matter voxels, limiting their interpretability. These findings suggest that changes in subcortical activation may contribute to motor function improvements following AIH therapy, implicating the basal ganglia-thalamo-cortical motor loop as a target of AIH-induced neuroplasticity. These results also indicate that AIH therapy modulates supraspinal motor circuitry, supporting further investigation of the cortical and subcortical effects of this emerging therapeutic treatment.