Outer retinal degenerative diseases destroy photoreceptors primarily in the retina, resulting in a profound vision loss. Fortunately, surviving retinal neurons can be electrically stimulated using retinal prostheses to re-transmit visual information. Although retinal prostheses are promising for sight restoration, the best performance is still sub-optimal. For the enhanced performance, it is critical to optimize stimulation parameters. This study explored how stimulus charge and current amplitude alters responses of retinal ganglion cells (RGCs). From the isolated mouse retina, spiking activities of alpha ON, OFF sustained, and OFF transient RGCs were recorded in response to epiretinally-delivered cathodal current pulses ranging from -10 to -80 μA. We have found that intermediate current amplitudes (-30 and -40 μA) maximize the response ratio of ON over OFF types. Also, the ON/OFF response ratio was always bigger for 10-ms-long than 5-ms-long stimuli. It was because, by the longer pulses, ON RGC responses were always significantly enhanced (p <; 0.05) while OFF RGC responses were minimally changed (p > 0.05). Given the earlier work reporting electrically-elicited responses are more natural in ON than OFF RGCs, the present study suggests effect strategies of more selective activation of ON RGCs for improved efficacy of retinal implant.
Objective . For individuals blinded by outer retinal degenerative diseases, retinal prostheses would be a promising option to restore sight. Unfortunately, however, the best performance of existing devices is still far removed from normal vision. One possible reason for the shortcoming is thought to be suboptimal stimulation conditions such as the waveform shape of electric stimulus. In this study, we explored the effects of varying waveforms on network-mediated responses arising in retinal ganglion cells (RGCs). Approach . We used a cell-attached patch clamp technique to record RGC spiking activities in the isolated mouse retina. ON alpha RGCs were targeted by soma size and their light responses to stationary spot flashes. Spiking in targeted RGCs was measured in response to an epiretinally-delivered cathodal current pulse in four waveforms: rectangular, center triangular, increasing and decreasing ramp shapes. Each waveform was tested at three durations (20, 10, and 5 ms) with adjusted amplitude for a range of total charges (50–400 nC). Main results . ON alpha RGCs always generated two bursts of spikes in responses to all stimuli conditions we tested. However, at a given charge, effects of differing waveforms were distinct in the two bursts. For the first burst, the increasing ramp was most effective among the four waveforms ( p < 0.05 for all pairwise comparisons with other waveforms). For example, in responses arising from 20 ms-long stimuli, the increasing ramp evoked ~44% more spikes on average than the rectangular shape which is the typical choice of neural stimulation. Also, the rectangular stimulus evoked the weakest response in the delayed burst arising from pulses of every duration. For instance, 20 ms-long stimuli in the three non-rectangular waveforms showed ~23% or more increment in spike counts compared to response arising from the rectangular one; but there was no statistical difference in response magnitudes across the non-rectangular waveforms. Significance . Although the rectangular waveform has been primarily used in retinal prostheses our results indicate that rectangular stimulus is not optimal for network-mediated responses of ON alpha RGCs. Instead, non-rectangular waveforms evoke stronger responses at a given charge, indicating higher charge-efficiency. Therefore, non-rectangular waveforms are expected to enhance clinical efficacy of retinal prostheses.
18 June 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Retinal prostheses use periodic repetition of electrical stimuli to form artificial vision. To enhance the reliability of evoked visual percepts, repeating stimuli need to evoke consistent spiking activity in individual retinal ganglion cells (RGCs). However, it is not well known whether outer retinal degeneration alters the consistency of RGC responses. Hence, here we systematically investigated the trial-to-trial variability in network-mediated responses as a function of the degeneration level. We patch-clamp recorded spikes in ON and OFF types of alpha RGCs from r d10 mice at four different postnatal days (P15, P19, P31, and P60), representing distinct stages of degeneration. To assess the consistency of responses, we analyzed variances in spike count and timing across repeats of the same stimulus delivered multiple times. We found the trial-to-trial variability of network-mediated responses increased considerably as the disease progressed. Compared to responses taken before degeneration onset, those of degenerate retinas showed up to ~70% higher variability (Fano Factor) in spike counts (p <; 0.001) and ~95% lower correlation level in spike timing (p <; 0.001). These results indicate consistency weakens significantly in electrically-evoked network-mediated responses and therefore raise concerns about the ability of microelectronic retinal implants to elicit consistent visual percepts at advanced stages of retinal degeneration.
We demonstrate a highly sensitive force sensor based on self-adjusting carbon nanotube (CNT) arrays. Aligned CNT arrays are directly synthesized on silicon microstructures by a space-confined growth technique which enables a facile self-adjusting contact. To afford flexibility and softness, the patterned microstructures with the integrated CNTs are embedded in polydimethylsiloxane structures. The sensing mechanism is based on variations in the contact resistance between the facing CNT arrays under the applied force. By finite element analysis, proper dimensions and positions for each component are determined. Further, high sensitivities up to 15.05%/mN of the proposed sensors were confirmed experimentally. Multidirectional sensing capability could also be achieved by designing multiple sets of sensing elements in a single sensor. The sensors show long-term operational stability, owing to the unique properties of the constituent CNTs, such as outstanding mechanical durability and elasticity.
Multi-vibrational-mode electrostatic energy harvesters are designed and micro-machined utilizing a simple silicon-on-insulator (SOI) wafer-based process. Enhanced adaptability to various vibrational environments is achieved in the proposed design by using serpentine springs attached to the fishbone-shaped inertial mass. The experimental results show that the developed device could convert an input vibration of 6 g at 1272 Hz to 2.96, 3.28, and 2.30 μW for different vibrational directions of 0°, 30°, and 45° with respect to a reference direction, respectively, when all serpentine springs are identical. An alternative device design using serpentine springs with different stiffnesses between x- and y-axes exhibited resonance frequencies at 1059 and 1635 Hz for an input vibrational direction of 45° and acceleration amplitude of 4 g, successfully generating 0.723 and 0.927 μW of electrical power at each resonance, respectively.
Neuromodulation using high frequency (>1 kHz) electric stimulation (HFS) enables preferential activation or inhibition of individual neural types, offering the possibility of more effective treatments across a broad spectrum of neurological diseases. To improve effectiveness, it is important to better understand the mechanisms governing activation and inhibition with HFS so that selectivity can be optimized. In this study, we measure the membrane potential (Vm) and spiking responses of ON and OFF α-sustained retinal ganglion cells (RGCs) to a wide range of stimulus frequencies (100–2500 Hz) and amplitudes (10–100 µA). Our findings indicate that HFS induces shifts in Vm, with both the strength and polarity of the shifts dependent on the stimulus conditions. Spiking responses in each cell directly correlate with the shifts in Vm, where strong depolarization leads to spiking suppression. Comparisons between the two cell types reveal that ON cells are more depolarized by a given amplitude of HFS than OFF cells—this sensitivity difference enables the selective targeting. Computational modeling indicates that ion-channel dynamics largely account for the shifts in Vm, suggesting that a better understanding of the differences in ion-channel properties across cell types may improve the selectivity and ultimately, enhance HFS-based neurostimulation strategies.