Martin Müller

Dr. Martin Müller

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
RZRoman Zazula
Roman Zazula
MMMichal Moravec
Michal Moravec
FPFrantišek Pehal
František Pehal
TNTomáš Nejtek
Tomáš Nejtek
MPMarek Protuš
Marek Protuš
MMMartin Müller
Martin Müller
Myristic acid is identified as a metabolite with the highest diagnostic sensitivity and specificity in the metabolome of patients with bacteraemia. Its significant decrease has been observed in patients with septic shock not responding to treatment. Another study has reported a close correlation of myristic acid levels with the outcome of severe trauma patients. Myristic acid concentrations were investigated in a cohort of septic patients and patients with Systemic Inflammatory Response Syndrome (SIRS) in 5 consecutive days following diagnosis and compared to healthy controls. The study population groups—Sepsis 34, SIRS 31, and Healthy Control 120 patients were included. Serum samples were analyzed using gas chromatography and mass spectrometry. The myristic acid levels in the Sepsis Group and SIRS Group were found to be significantly higher when compared to healthy controls. The serum concentration of myristic acid in septic patients with bacteraemia was higher than in septic patients without bacteraemia. Most patients with sepsis and SIRS had the highest levels of myristic acid within 24 h after an established diagnosis. Myristic acid should be considered as a new candidate marker of severe inflammation and sepsis. A simplified analysis and sufficient body of validated data are necessary steps towards the introduction of this metabolite into routine clinical practice.

8 April 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
VSVladimír Sobota
Vladimír Sobota
MMMartin Müller
Martin Müller
KRKarel Roubik
Karel Roubik
Electrical impedance tomography (EIT) is a noninvasive imaging modality that allows real-time monitoring of regional lung ventilation. The aim of the study is to investigate whether fast saline infusion causes changes in lung impedance that could affect the interpretation of EIT data. Eleven pigs were anaesthetized and mechanically ventilated. A bolus of 500 mL of normal saline was administered rapidly. Two PEEP steps were performed to allow quantification of the effect of normal saline on lung impedance. The mean change of end-expiratory lung impedance (EELI) caused by the saline bolus was equivalent to a virtual decrease of end-expiratory lung volume (EELV) by 227 (188–250) mL and decremental PEEP step of 4.40 (3.95–4.59) cmH2O (median and interquartile range). In contrast to the changes of PEEP, the administration of normal saline did not cause any significant differences in measured EELV, regional distribution of lung ventilation determined by EIT or in extravascular lung water and intrathoracic blood volume. In conclusion, EELI can be affected by the changes of EELV as well as by the administration of normal saline. These two phenomena can be distinguished by analysis of regional distribution of lung ventilation.

20 September 2023 in Microorganisms
Verified
Journal Article
Open access
PDF file
TNTomáš Nejtek
Tomáš Nejtek
MMMartin Müller
Martin Müller
MMMichal Moravec
Michal Moravec
MPMiroslav Prucha
Miroslav Prucha
RZRoman Zazula
Roman Zazula
Sepsis (and septic shock) is on of the most common causes of death worldwide. Bacteremia often, but not necessarily, occurs in septic patients, but the impact of true bacteremia on a patient’s clinical characteristics and outcome remains unclear. The main aim of this study was to compare the characteristics and outcome of a well-defined cohort of 258 septic patients with and without bacteremia treated in the intensive care unit (ICU) of a tertiary center hospital in Prague, Czech Republic. As expected, more frequently, bacteremia was present in patients without previous antibiotic treatment. A higher proportion of bacteremia was observed in patients with infective endocarditis as well as catheter-related and soft tissue infections in contrast to respiratory sepsis. Multivariant analysis showed increased severity of clinical status and higher Charlson comorbidity index (CCI) as variables with significant influence on mortality. Bacteremia appears to be associated with higher mortality rates and length of ICU stay in comparison with nonbacteremic counterparts, but this difference did not reach statistical significance. The presence of bacteremia, apart from previous antibiotic treatment, may be related to the site of infection.

12 September 2015 in Mycopathologia
Verified
Journal Article
Closed access
PDF file
TTTomas Tyll
Tomas Tyll
PLPavlina Lyskova
Pavlina Lyskova
Vit HubkaVit Hubka
Vit Hubka
MMMartin Müller
Martin Müller
LZLubomir Zelenka
Lubomir Zelenka
PHPetr Hamal
Petr Hamal

23 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
KKKristyna Koldova
Kristyna Koldova
ARAles Rara
Ales Rara
MMMartin Müller
Martin Müller
TTTomas Tyll
Tomas Tyll
KRKarel Roubik
Karel Roubik
Laparoscopic surgery with capnoperitoneum brings many advantages to patients, but also emphasizes the negative impact of anesthesia and mechanical ventilation on the lungs. Even though many studies use electrical impedance tomography (EIT) for lung monitoring during these surgeries, it is not clear what the best position of the electrode belt on the patient’s thorax is, considering the cranial shift of the diaphragm. We monitored 16 patients undergoing a laparoscopic surgery with capnoperitoneum using EIT with two independent electrode belts at different tomographic levels: in the standard position of the 4th–6th intercostal space, as recommended by the manufacturer, and in a more cranial position at the level of the axilla. Functional residual capacity (FRC) was measured, and a recruitment maneuver was performed at the end of the procedure by raising the positive end-expiratory pressure (PEEP) by 5 cmH2O. The results based on the spectral analysis of the EIT signal show that the ventilation-related impedance changes are not detectable by the belt in the standard position. In general, the cranial belt position might be more suitable for the lung monitoring during the capnoperitoneum since the ventilation signal remains dominant in the obtained impedance waveform. FRC was significantly decreased by the capnoperitoneum and remained lower also after desufflation.

27 March 2012 in The International Journal of Artificial Organs
Verified
Journal Article
Closed access
KRKarel Roubik
Karel Roubik
RZRoman Zazula
Roman Zazula
ASAdéla Strnadová
Adéla Strnadová
VZVladimír Zábrodský
Vladimír Zábrodský
ASAntonín Spálený
Antonín Spálený
TTTomáš Tyll
Tomáš Tyll
Introduction: The use of helium-oxygen mixture (heliox) for ventilation has an advantage in patients with obstruction of the airways. The physical properties of helium enable an easier gas flow through the airways; this enables easier breathing for the patient when compared to standard ventilation of air. A high cost of heliox falls within the factors that limit the use of heliox in clinical practice. At present, heliox is administered by use of an open circuit. The aim of this study is to propose a way of heliox administration that reduces heliox consumption but does not affect the positive heliox effects upon the airway resistance. Methods: To minimize consumption of heliox, a semi-closed circuit has been designed. The circuit is a modification of an anesthetic circuit composed of parts with the lowest possible resistances. As any circuit has its own resistance, the evaluation of its possible negative effect upon the work of breathing of patients with exacerbation of chronic obstructive pulmonary disease (COPD) has been conducted. Results: A semi-closed circuit for heliox administration has been constructed and evaluated. The intrinsic resistance of both the inspiratory and expiratory limbs of the circuit is less than 140 Pa·s/l. This resistance does not represent a significant workload for a patient with COPD exacerbation whose airway resistance is 10 to 20 fold higher. Conclusions: The designed semi-closed circuit offers a potential benefit of heliox in patients with COPD exacerbation.