This paper describes the authors' experience in the assessment of laboratory activities based on an open source software package for power system analysis, namely, Power System Analysis Toolbox (PSAT). PSAT is currently used in several universities for both undergraduate and graduate courses. PSAT has also its own Web forum, which provides support to students and researchers all around the world, thus resulting in an almost unique example of ldquovirtual laboratoryrdquo over the Internet. This paper attempts to answer through a variety of real-life examples the following open questions: What are the practical and pedagogical advantages of using an open source software with respect to proprietary software for power system analysis? What happens if a power system virtual laboratory is freely available on the Web? What is the difference between a class-based and a Web-based virtual laboratory?
15 February 2013 in IEEE Transactions on Instrumentation and Measurement
OpenPMU is an open platform for the development of phasor measurement unit (PMU) technology. A need has been identified for an open-source alternative to commercial PMU devices tailored to the needs of the university researcher and for enabling the development of new synchrophasor instruments from this foundation. OpenPMU achieves this through open-source hardware design specifications and software source code, allowing duplicates of the OpenPMU to be fabricated under open-source licenses. This paper presents the OpenPMU device based on the Labview development environment. The device is performance tested according to the IEEE C37.118.1 standard. Compatibility with the IEEE C37.118.2 messaging format is achieved through middleware which is readily adaptable to other PMU projects or applications. Improvements have been made to the original design to increase its flexibility. A new modularized architecture for the OpenPMU is presented using an open messaging format which the authors propose is adopted as a platform for PMU research.
26 April 2010 in IEEE Transactions on Power Systems
With amplitude and phase information, time-synchronized measured phasor data of bus voltages and line currents can be used to calculate, without iterations, the voltage phasor on neighboring buses. In some phasor measurement units (PMUs), it has been observed that the voltage and current phasors exhibit phase biases, which can corrupt the conventional state estimator solution if it is augmented with such biased phasor data. This paper presents a new approach for synchronized phasor measurement-based state estimation, which can perform phasor angle bias correction given measurement redundancy. In this approach, polar coordinates are used as the state variables, because the magnitude and phase are largely independent measurements. The state estimation is formulated as an iterative least-squares problem, and its application to portions of the AEP high-voltage transmission system is illustrated.
29 October 2010 in European Transactions on Electrical Power
This paper experimentally assesses the impact of time synchronization spoofing attacks (TSSA) on synchrophasor-based wide-area monitoring, protection and control (WAMPAC) applications. Phase angle monitoring, anti-islanding protection, and power oscillation damping applications are investigated. TSSA are created using a real-time (RT) IRIG-B signal generator and power system models are executed using an RT simulator with commercial phasor measurement units (PMUs) coupled to them as hardware-in-the-loop. Because PMUs utilize time synchronization signals to compute synchrophasors, an error in the PMUs' time input introduces a proportional phase error in the voltage or current phase measurements provided by the PMU. The experiments conclude that a phase angle monitoring application will show erroneous power transfers, whereas the anti-islanding protection mal-operates and the damping controller introduces negative damping in the system as a result of the time synchronization error incurred in the PMUs due to TSSA. The proposed test-bench and TSSA approach can be used to investigate the impact of TSSA on any WAMPAC application and to determine the time synchronization error threshold that can be tolerated by these WAMPAC applications.
The iTesla Power Systems Library (iPSL) is a Modelica package providing a set of power system components for phasor time-domain modeling and simulation. The Modelica language provides a systematic approach to develop models using a formal mathematical description, that uniquely specifies the physical behavior of a component or the entire system. Furthermore, the standardized specification of the Modelica language (Modelica Association [1]) enables unambiguous model exchange by allowing any Modelica-compliant tool to utilize the models for simulation and their analyses without the need of a specific model transformation tool. As the Modelica language is being developed with open specifications, any tool that implements these requirements can be utilized. This gives users the freedom of choosing an Integrated Development Environment (IDE) of their choice. Furthermore, any integration solver can be implemented within a Modelica tool to simulate Modelica models. Additionally, Modelica is an object-oriented language, enabling code factorization and model re-use to improve the readability of a library by structuring it with object-oriented hierarchy. The developed library is released under an open source license to enable a wider distribution and let the user customize it to their specific needs. This paper describes the iPSL and provides illustrative application examples