Marjolein van der Linden

Marjolein van der Linden

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
EAEmad Arasteh
Emad Arasteh
EVEsther S. Veldhoen
Esther S. Veldhoen
XLXi Long
Xi Long
MPMaartje van Poppel
Maartje van Poppel
MLMarjolein van der Linden
Marjolein van der Linden
Jeroen DudinkJeroen Dudink
Jeroen Dudink
Unobtrusive monitoring of children’s heart rate (HR) and respiratory rate (RR) can be valuable for promoting the early detection of potential health issues, improving communication with healthcare providers and reducing unnecessary hospital visits. A promising solution for wireless vital sign monitoring is radar technology. This paper presents a novel approach for the simultaneous estimation of children’s RR and HR utilizing ultra-wideband (UWB) radar using a deep transfer learning algorithm in a cohort of 55 children. The HR and RR are calculated by processing radar signals via spectrogram from time epochs of 10 s (25 sample length of hamming window with 90% overlap) and then transforming the resultant representation into 2-dimensional images. These images were fed into a pre-trained Visual Geometry Group-16 (VGG-16) model (trained on ImageNet dataset), with weights of five added layers fine-tuned using the proposed data. The prediction on the test data achieved a mean absolute error (MAE) of 7.3 beats per minute (BPM < 6.5% of average HR) and 2.63 breaths per minute (BPM < 7% of average RR). We also achieved a significant Pearson’s correlation of 77% and 81% between true and extracted for HR and RR, respectively. HR and RR samples are extracted every 10 s.

25 April 2024 in Pediatric Pulmonology
Verified
Journal Article
Open access
MLMarjolein van der Linden
Marjolein van der Linden
EVEsther S. Veldhoen
Esther S. Veldhoen
EAEmad Arasteh
Emad Arasteh
XLXi Long
Xi Long
TAThomas Alderliesten
Thomas Alderliesten
Jeroen DudinkJeroen Dudink
Jeroen Dudink
Pediatric sleep‐related breathing disorders, or sleep‐disordered breathing (SDB), cover a range of conditions, including obstructive sleep apnea, central sleep apnea, sleep‐related hypoventilation disorders, and sleep‐related hypoxemia disorder. Pediatric SDB is often underdiagnosed, potentially due to difficulties associated with performing the gold standard polysomnography in children. This scoping review aims to: (1) provide an overview of the studies reporting on safe, noncontact monitoring of respiration in young children, (2) describe the accuracy of these techniques, and (3) highlight their respective advantages and limitations. PubMed and EMBASE were searched for studies researching techniques in children <12 years old. Both quantitative data and the quality of the studies were analyzed. The evaluation of study quality was conducted using the QUADAS‐2 tool. A total of 19 studies were included. Techniques could be grouped into bed‐based methods, microwave radar, video, infrared (IR) cameras, and garment‐embedded sensors. Most studies either measured respiratory rate (RR) or detected apneas; n = 2 aimed to do both. At present, bed‐based approaches are at the forefront of research in noncontact RR monitoring in children, boasting the most sophisticated algorithms in this field. Yet, despite extensive studies, there remains no consensus on a definitive method that outperforms the rest. The accuracies reported by these studies tend to cluster within a similar range, indicating that no single technique has emerged as markedly superior. Notably, all identified methods demonstrate capability in detecting body movements and RR, with reported safety for use in children across the board. Further research into contactless alternatives should focus on cost‐effectiveness, ease‐of‐use, and widespread availability.