Yude Ding

Mr. Yude Ding

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2024 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Open access
FYFan Yang
Fan Yang
JCJianping Chen
Jianping Chen
RCRuijue Cao
Ruijue Cao
QTQingwei Tang
Qingwei Tang
HLHaiyan Liu
Haiyan Liu
LWLinhong Wang
Linhong Wang
Background: Robot‐assisted implant surgery has emerged as a novel digital technology, and the accuracy need further assessment.Purpose: This study aimed to compare the accuracy of single dental implant placement between a novel semi‐active robot‐assisted implant surgery (RAIS) method and the conventional free‐hand implant surgery (FHIS) method through a multicenter, randomized controlled clinical trial.Materials and Methods: Patients requiring single dental implant placement were recruited and randomized into RAIS and FHIS group. Deviations at the platform, apex, and angle between the planned and final implant positions were assessed in both groups. Additionally, the evaluation of instrument and surgical complications was examined.Results: A total of 140 patients (median age: 35.35 ± 12.55 years; 43 males, 97 females) with 140 implants from four different research centers were included, with 70 patients (70 implants) in the RAIS group and 70 patients (70 implants) in the FHIS group. In the RAIS and FHIS groups, the median platform deviations were 0.76 ± 0.36 mm and 1.48 ± 0.93 mm, respectively (p < 0.001); median apex deviations were 0.85 ± 0.48 mm and 2.14 ± 1.25 mm, respectively (p < 0.001); and median angular deviations were 2.05 ± 1.33° and 7.36 ± 4.67°, respectively (p < 0.001). Similar significant difference also presented between RAIS and FHIS group in platform vertical/horizontal deviation, apex vertical/horizontal deviation. Additionally, implants with self‐tapping characteristics exhibited significantly larger deviations compared with those without self‐tapping characteristics in the RAIS group. Both RAIS and FHIS methods demonstrated comparable morbidity and safety pre‐ and post‐operation.Conclusions: The results indicated that the RAIS method demonstrated superior accuracy in single dental implant placement compared with the FHIS method. Specifically, RAIS exhibited significantly smaller deviations in platform, apex, and angular positions, as well as platform and apex vertical/horizontal deviations.This clinical trial was not registered prior to participant recruitment and randomization. https://www.chictr.org.cn/showproj.html?proj=195045.

29 October 2023 in Journal of Dentistry
Verified
Journal Article
Open access
YDYude Ding
Yude Ding
YZYuxin Zheng
Yuxin Zheng
RCRunzhi Chen
Runzhi Chen
RCRuijue Cao
Ruijue Cao
JCJianping Chen
Jianping Chen
FYFan Yang
Fan Yang
Objective: This study aimed to evaluate the accuracy of dental implant placement at single-tooth sites using a novel semi-autonomous robotic-assisted surgery system (sa-RASS). Methods: Patients with single missing teeth were included. Cone-beam computed tomography (CBCT) was performed prior to surgery using a U-shaped silicone tube to develop a virtual implant placement and drilling plan. The sa-RASS was used for implant osteotomy and placement in conjunction with a surgeon. Cone-beam computed tomography data were utilized to evaluate deviations between planned and placed implants using a three-dimensional Slicer software. Data were analysed using the t-test and analysis of variance. Statistical significance was considered at P<0.05. Results: Nineteen implants were placed using the sa-RASS. No adverse events or complications were observed during the surgery. Mean ± standard deviations between planned and postoperative implant positions were 0.90 ± 0.41 mm at the platform, 1.04 ± 0.47 mm at the apex, and 3.37 ± 1.51° for angulation. In a lateral direction, deviations were 0.72 ± 0.38 mm and 0.88 ± 0.47 mm at the platform and apex, respectively. Deviations in depth were all < 1 mm at both the platform (0.46 ± 0.33 mm) and apex (0.45 ± 0.32 mm). The apex deviation was greater than that at the platform (p = 0.036 < 0.05), mainly in the lateral distance (p = 0.037 < 0.05). Conclusions: The current study illustrates that this robotic implant system is sufficiently accurate for single-tooth implant placement. Clinical significance This study provides significant evidence to support the use of sa-RASS as a potential alternative to static guided surgery and dynamic navigation in dental implant surgery.

15 October 2024 in Frontiers in Materials
Verified
Journal Article
Open access
PDF file
ZXZhuoheng Xia
Zhuoheng Xia
BGBin Guo
Bin Guo
DWDanni Wu
Danni Wu
FYFan Yang
Fan Yang
YDYude Ding
Yude Ding
Regeneration of soft tissues, especially those requiring complex vascularization, is a major challenge in the field of tissue engineering. The current types of tissue engineering scaffolds include sponges, electric spinning silk, hydrogels, and 3D printed biomaterials. Among them, hydrogels have the unique property of mimicking extracellular matrix (ECM), which can provide a relatively stable microenvironment for cellular activities and facilitate cell adhesion, proliferation, and differentiation; thus, have become a promising scaffold. In this paper, we present a review of the commonly used types of natural hydrogels and their applications as scaffolds in tissue vascularization. First, we enumerate the importance and advantages of several types of commonly used hydrogels of natural origin in terms of fabricating vascularized tissues or organs. Second, we discuss two different formation modalities of blood vessels, as well as natural hydrogel-based vascularization strategies, including carrying growth factors, stem cell delivery, special scaffold structures and pharmaceutical-enhanced strategy. In addition, we describe the crosslinking strategies of hydrogels as scaffolds for regeneration of vascularized soft tissues, as well as the factors affecting it. Finally, new insights are provided for the development of natural hydrogel-based vascularized soft tissue regeneration research.

31 December 2025 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
FYFan Yang
Fan Yang
XWXing Wu
Xing Wu
YZYukang Zhang
Yukang Zhang
XLXinrui Lang
Xinrui Lang
YYYing Yang
Ying Yang
LWLinhong Wang
Linhong Wang
Precise evaluation of bone gain after maxillary sinus augmentation is critical for optimizing implant therapy yet manual measurements remain time consuming. This study validated a fully automated deep learning system named SA-ai to quantify bone augmentation. A paired CBCT dataset from 85 patients was used to train and test the system which integrates a 2D U-Net for sinus contour and a 3D V-Net for maxilla segmentation. The system achieved a Dice coefficient of 93.2% and registration RMSE of 1.046 mm. Clinical validation against manual measurements showed excellent agreement for bone volume (ICC = 0.993) and other parameters. Bias analysis confirmed measurement stability while workflow efficiency improved over 20-fold compared to manual methods. This registration subtraction paradigm delivers an automated and objective solution for longitudinal monitoring of bone graft volume including one-stage implant cases potentially standardizing clinical evaluation of post augmentation bone dynamics.

22 November 2024 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
FYFan Yang
Fan Yang
JCJianping Chen
Jianping Chen
LWLinhong Wang
Linhong Wang
YDYude Ding
Yude Ding
Translational studies evaluating the feasibility, accuracy, and safety of semi-autonomous implant robots, from model test to animal experiment and clinical trial, are currently lacking. The purpose of this study was to evaluate the accuracy and safety of a novel semi-autonomous robotic-assisted surgical system (sa-RASS) in implant placement. A translational study was conducted to assess the application of the sa-RASS in a model test, an animal experiment, and a clinical controlled trial. The study included 45 resin models in the model test, 7 male beagle dogs in the animal experiment, and 60 participants who were recruited and randomly assigned to a freehand or a sa-RASS group in the clinical trial. The accuracy, surgical morbidity, complications, operator ratings of instrument safety, and satisfaction were recorded. Cone-beam computed tomography data were used to evaluate deviations between planned and placed implants. The data on deviations were analyzed using the Mann-Whitney U test. A linear regression model was established to analyze the variations in the deviations (α=.05). The mean ±standard deviation of the platform, apex, and angulation deviations were 0.98 ±0.53 mm, 1.10 ±0.52 mm, and 1.45 ±0.60 degrees in the model test and 0.58 ±0.19, 0.59 ±0.22 mm, and 1.88 ±0.71 degrees in the animal experiment. In the clinical controlled study, the platform, apex, and angular deviations of the sa-RASS group and freehand group were 0.93 ±0.50 mm versus 1.45 ±0.86 mm (P<.01), 1.07 ±0.63 mm versus 2.05 ±1.16 mm (P<.001), and 3.10 ±1.68 degrees versus 7.94 ±3.55 degrees (P<.001). No complications, such as early implant failure, intraoperative hemorrhage, injuries to adjacent structures, or implant displacement beyond the apical anatomic limit, were observed in the sa-RASS group. The results of the linear regression model showed that age, sex, bone density, implant position, implant diameter, and length did not significantly influence the accuracy of implantation at the apex or the angulation (P>.05). The sa-RASS was found to be more accurate than freehand placement, with high operational safety and low surgical morbidity.

29 May 2023 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Open access
YDYude Ding
Yude Ding
HZHuajun Zhou
Huajun Zhou
WZWentao Zhang
Wentao Zhang
JCJianping Chen
Jianping Chen
YZYuanna Zheng
Yuanna Zheng
FYFan Yang
Fan Yang
Background: The survival rate, marginal bone loss and soft tissue health of the Ankylos implants and the balanced base abutments in all‐on‐four or six implant restoration of edentulous or terminal dentition patients has not been reported in the clinical research.Purpose: This retrospective study aimed to evaluate the Ankylos implants and the balanced base abutments in all‐on‐four or six implant restoration of edentulous or terminal dentition patients after 1–8 years of follow‐up.Materials and Methods: A retrospective study was conducted based on the medical records of 33 patients who received all‐on‐four or six treatments from April 2014 to May 2020. Four radiographic examinations [immediate postoperative (T0), definitive restorations (T1), 1–3 years after prosthetic restorations (T2), and more than 3 years after prosthetic restorations (T3)] were obtained to evaluate vertical bone height (VBH). We also calculated the survival rate and examined the condition of soft tissue with this implant system in edentulous or terminal dentition patients. Three‐level linear model analyses were used to explore potential risk factors for VBH changes on the mesial and distal sides. The generalized linear model was used to analyze the influencing factors of BOP and plaque.Results: A total of 218 implants were included in this study. The cumulative survival rate of the implants was 97.25% before the definitive prosthesis, 96.33% within 3 years of follow‐up and 95.32% after more than 3 years of follow‐up. The mean ± standard deviation (SD) bone losses of the VBH were 0.27 ± 0.05 mm (T1‐T3) on the mesial side and 0.49 ± 0.06 mm (T1‐T3) on the distal side. During 1–8 years of follow‐up, the height and angle of the abutment (p < 0.001), the mandible implant site (p < 0.001), the length of the implant (p = 0.014 < 0.05) and age (p = 0.029 < 0.05) showed statistically significant effects on vertical mesial bone height (VMBH) and vertical distal bone height (VDBH). The risk of BOP among participants who brushed three times a day was lower than those who brushed less than three times. The plaque risk of short abutment height was higher than the long abutment.Conclusion: The current study showed that the Ankylos implants with the balanced base abutments in all‐on‐four or six implants treatment is a viable and predictable option with a high survival rate and low marginal bone loss in edentulous or terminal dentition patients. VBH around the implants was strongly associated with the mandible implant site, abutment height and angle, the length of the implant and age. Moreover, teeth‐brushing times and abutment height significantly affect soft tissue health.