Jeong-Eun Hwang

Ms. Jeong-Eun Hwang

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2023 in Nutrients
Verified
Journal Article
Open access
PDF file
MMMatthew P. Madore
Matthew P. Madore
JHJeong-Eun Hwang
Jeong-Eun Hwang
JPJin-Young Park
Jin-Young Park
SASeoeun Ahn
Seoeun Ahn
HJHyojee Joung
Hyojee Joung
Ock ChunOck Chun
Ock Chun
Despite consistent evidence that greater consumption of fruits and vegetables (FV) is associated with significant reductions in chronic disease morbidity and mortality, the majority of adults in the United States consume less than the amounts recommended by public health agencies. As such, there is a critical need to design and implement effective programs and policies to facilitate increases in FV consumption for the prevention of these diseases. To accomplish this, an accurate, inexpensive, and convenient method for estimating the dietary FV intake is required. A promising method for quantifying the FV intake via proxy that has gained interest in recent years is the measurement of skin carotenoid levels via spectroscopy-based devices. However, there exist certain dietary and non-dietary factors that may affect the skin carotenoid levels independently of the dietary intake of carotenoids. In order to validate the ability of this method to accurately estimate the FV intake among diverse demographics, these factors must be identified and taken into consideration. Therefore, this narrative review seeks to summarize the available research on factors that may affect the skin carotenoid levels, determine current gaps in knowledge, and provide guidance for future research efforts seeking to validate spectroscopy-measured skin carotenoid levels as a means of accurately estimating the FV intake among various populations.

4 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JHJeong-Eun Hwang
Jeong-Eun Hwang
JPJin-Young Park
Jin-Young Park
MJMyoung Hoon Jung
Myoung Hoon Jung
KEKunsun Eom
Kunsun Eom
HMHyun Seok Moon
Hyun Seok Moon
YKYoon Jae Kim
Yoon Jae Kim
Resonance Raman spectroscopy (RRS) has been used as a reference method for measuring skin carotenoid levels (SCL), which indicate vegetable and fruit intake. However, RRS is not an easy-to-use method in SCL measurement due to its complicated implementation. In this study, a commercial spectrophotometer based on reflection spectroscopy (RS), which is relatively simple and inexpensive, was evaluated to confirm usability compared with RRS in measuring SCL. To investigate the agreement between RS and RRS, eighty participants were randomly assigned to a high-carotenoid diet group (21 mg/day of total carotenoids) or a control-carotenoid diet group (14 mg/day of total carotenoids) during a 6-week whole-diet intervention period and a 4-week tracking period. Strong correlations between the RS and RRS methods were observed at baseline (r = 0.944) and the entire period (r = 0.930). The rate of SCL increase was similar during the diet intervention; however, the initiation of the SCL decrease in RS was slower than in RRS during the tracking period. To confirm the agreement of RS and RRS from various perspectives, new visualization tools and indices were additionally applied and confirmed the similar response patterns of the two methods. The results indicate that the proposed RS method could be an alternative to RRS in SCL measurements.

19 November 2023 in Nutrition
Verified
Journal Article
Closed access
SASeoeun Ahn
Seoeun Ahn
JHJeong-Eun Hwang
Jeong-Eun Hwang
YKYoon Jae Kim
Yoon Jae Kim
KEKunsun Eom
Kunsun Eom
MJMyoung Hoon Jung
Myoung Hoon Jung
HJHyojee Joung
Hyojee Joung

15 May 2023 in British Journal of Nutrition
Verified
Journal Article
Open access
PDF file
SASeoeun Ahn
Seoeun Ahn
SASungmo Ahn
Sungmo Ahn
HJHyeongseok Jang
Hyeongseok Jang
KEKunsun Eom
Kunsun Eom
YKYoon Jae Kim
Yoon Jae Kim
HJHyojee Joung
Hyojee Joung
Blood carotenoid concentration measurement is considered the gold standard for fruit and vegetable (F&V) intake estimation; however, this method is invasive and expensive. Recently, skin carotenoid status (SCS) measured by optical sensors has been evaluated as a promising parameter for F&V intake estimation. In this cross-sectional study, we aimed to validate the utility of resonance Raman spectroscopy (RRS)-assessed SCS as a biomarker of F&V intake in Korean adults. We used data from 108 participants aged 20–69 years who completed SCS measurements, blood collection and 3-d dietary recordings. Serum carotenoid concentrations were quantified using HPLC, and dietary carotenoid and F&V intakes were estimated via 3-d dietary records using a carotenoid database for common Korean foods. The correlations of the SCS with serum carotenoid concentrations, dietary carotenoid intake and F&V intake were examined to assess SCS validity. SCS was positively correlated with total serum carotenoid concentration (r = 0·52, 95 % CI = 0·36, 0·64, P < 0·001), serum β-carotene concentration (r = 0·60, 95 % CI = 0·47, 0·71, P < 0·001), total carotenoid intake (r = 0·20, 95 % CI = 0·01, 0·37, P = 0·04), β-carotene intake (r = 0·30, 95 % CI = 0·11, 0·46, P = 0·002) and F&V intake (r = 0·40, 95 % CI = 0·23, 0·55, P < 0·001). These results suggest that SCS can be a valid biomarker of F&V intake in Korean adults.