Exposure to small public urban green spaces (SPUGS) has been demonstrated to have mental benefits for older adults. However, studies on identifying the objective environmental features of SPUGS and their effects on mental restoration for older adults remain limited. This study employed a multilevel regression model to investigate the restorative and vitalizing effects of the environmental features of 11 SPUGS in Tokyo. Onsite measurements were conducted in Kita-Ku, and 202 older adults were surveyed. The results showed that: (1) The fitting curve of the green view index and Restoration Outcome Scale (ROS) score showed an inverted U shape—both green view index and boundary enclosure had a strong impact on the mental restoration of older adults; (2) The colorfulness index showed the strongest relationship with the vitalizing effect. (3) The sky view factor and number of seats only influenced the ROS score, while the results of revitalization suggest that large areas of water should be avoided. (4) Physiological Equivalent Temperature (PET) was also confirmed to have negative effects on the mental restoration of older adults in autumn. These empirical findings can be used as a resource to promote the mental health of older adults in the design of SPUGS in high-density Asian countries.
15 October 2007 in International Journal of Climatology
A desiccant air-conditioning system was developed as a latent-load-processing air conditioner in a dedicated outdoor air system during the summer. This study investigated the application of this air-conditioning system to humidification during the winter without using make-up water, thereby eliminating the cause of microbial contamination in air-conditioning systems. The experiments were conducted with a system used for summer applications to determine the feasibility of adsorbing vapor from outdoor air and supplying it to an indoor space. The humidification performance, energy efficiency, and operating conditions were examined. Although the conditions were subpar because the experiments were performed with an actual dedicated outdoor air system, the results showed that it is possible to supply air with a minimum humidity ratio of 5.8 g/kg dry air (DA) when the humidity ratio of outdoor air ranges from 1.8 to 2.3 g/kg DA. The minimum humidification performance required for a dedicated outdoor air system was achieved by increasing the airflow rate of the moisture-adsorption side to 2–3 times that of the humidification side. In addition, air leaking from the moisture-adsorption side to the humidification side, improving the mechanical structure, such as by the insulation of the moisture-adsorption side, and an efficient operating method were examined for humidification during the winter.
In the context of increasing energy demands and the integration of renewable energy sources, this review focuses on recent advancements in energy storage control strategies from 2016 to the present, evaluating both experimental and simulation studies at component, system, building, and district scales. Out of 426 papers screened, 147 were assessed for eligibility, with 56 included in the final review. As a first outcome, this work proposes a novel classification and taxonomy update for advanced storage control systems, aiming to bridge the gap between theoretical research and practical implementation. Furthermore, the study emphasizes experimental case studies, moving beyond numerical analyses to provide practical insights. It investigates how the literature on energy storage is enhancing building flexibility and resilience, highlighting the application of advanced algorithms and artificial intelligence methods and their impact on energy and financial savings. By exploring the correlation between control algorithms and the resulting benefits, this review provides a comprehensive analysis of the current state and future perspectives of energy storage control in smart grids and buildings.
In this paper, we present a performance-based approach to building configuration design to improve the urban ventilation potential at the conceptual design stage, and we demonstrate its application through a case study. The target performance optimized was the ventilation potential of a district, including a region of interest at a spatial scale of hundreds of meters. To estimate this performance, we used computational fluid dynamics (CFD), coupled with an evolutionary algorithm, to optimize the design alternatives to produce the building configuration most suitable for a given set of site conditions. Three calculation components must be assembled for a CFD-based design optimization: an optimizer, a geometry/mesh generator, and a CFD solver. To provide links between the calculation components, we utilized an in-house parametric design program. A case study was conducted to test the applicability of the proposed design method to identify the optimal solutions that minimize adverse effects on the ventilation potential of the surrounding area. For a configuration of buildings in a dense urban area, the proposed design method successfully improved the design alternatives. The results show that the urban ventilation potential in the case of the optimized building configuration is 16% greater than that of the initial building configuration.
17 May 2021 in International Journal of Biometeorology