An air-coupled transducer was developed in this study, utilizing hollow glass microsphere-organosilicon composites as an acoustically matching layer, which demonstrated outstanding acoustic performance. Firstly, a comparison and analysis of the properties and advantages of different substrates was carried out to determine the potential application value of organosilicon substrates. Immediately after, the effect of hollow glass microspheres with different particle sizes and mass fractions on the acoustic properties of the matching layer was analyzed. It also evaluated the mechanical properties of the matching layer before and after optimization. The findings indicate that the optimized composite material attained a characteristic acoustic impedance of 1.04 MRayl and an acoustic attenuation of 0.43 dB/mm, displaying exceptional acoustic performance. After encapsulating the ultrasonic transducer using a 3D-printed shell, we analyzed and compared its emission and reception characteristics to the commercial transducer and found that its emission acoustic pressure amplitude and reception voltage amplitude were 34% and 26% higher, respectively. Finally, the transducer was installed onto a homemade ultrasonic flow meter for practical application verification, resulting in an accuracy rate of 97.4%.
The accuracy of ultrasonic flowmeter time delay measurement is directly affected by the processing method of the ultrasonic echo signal. This paper proposes a method for estimating the time delay of the ultrasonic gas flowmeter based on the Variational Mode Decomposition (VMD)–Hilbert Spectrum and Cross-Correlation (CC). The method improves the accuracy of the ultrasonic gas flowmeter by enhancing the quality of the echo signal. To denoise forward and reverse ultrasonic echo signals collected at various wind speeds, a Butterworth filter is initially used. The ultrasonic echo signals are then analyzed by Empirical Mode De-composition (EMD) and VMD analysis to obtain the Intrinsic Mode Function (IMF) containing distinct center frequencies, respectively. The Hilbert spectrum time–frequency diagram is used to evaluate the results of the VMD and EMD decompositions. It is found that the IMF decomposed by VMD has a better filtering performance and better anti-interference performance. Therefore, the IMF with a better effect is selected for signal reconstruction. The ultrasonic time delay is then calculated using the Cross-Correlation algorithm. The self-developed ultrasonic gas flowmeter was tested on the experimental platform of the gas flow standard devices using this signal processing method. The results show a maximum indication error of 0.84% within the flow range of 60–606 m3/h, with a repeatability of no more than 0.29%. These results meet the 1-level accuracy requirements as outlined in the national ultrasonic flowmeters calibration regulation JJG1030-2007.
5 November 2026 in BMC Medical Informatics and Decision Making
Due to the limited field of view of endoscopic cameras and the lack of depth perception, it is challenging for diagnosticians to accurately perceive the lo
Accurate and stable measurement of carbon dioxide (CO2) concentrations in industrial flue gases is critical for emissions monitoring and carbon management. The present study developed a wavelength-modulated tunable diode laser absorption spectroscopy (WMS-TDLAS) system for measuring high-concentration carbon dioxide (CO2) in flue gases, covering a range of 3–20% (by volume). To mitigate optical intensity fluctuations caused by particle scattering and detector gain drift in harsh flue gas environments, a normalized second harmonic (2f/1f) detection scheme based on a single-harmonic peak was employed. A digital phase-locked amplification algorithm replaces the conventional hardware lock-in amplifier, enabling simultaneous demodulation of multiple harmonic components and enhancing system integration. A comparison of the digital locking method with a commercial lock-in amplifier reveals that the former demonstrates comparable or superior stability, with relative standard deviations of 0.04% for the 2f signal and 0.02% for the first-harmonic signal. In order to address the sensitivity degradation of WMS-TDLAS at elevated CO2 concentrations, a pressure control strategy was introduced. Maintaining the measurement cell pressure at 70 ± 0.005 kPa resulted in a 2.74-fold enhancement in system sensitivity at 13.01% CO2 and a more than one-order-of-magnitude increase at 20.01% CO2 compared to operation at atmospheric pressure. Concentration measurement error under reduced pressure also decreased from 1.101% to 0.075%. The system exhibited 0.6% repeatability in high-concentration CO2 measurements, signifying its aptitude for industrial flue gas monitoring applications.
About Me
1.LiangZhang,associate fellow
2.Doctor,D,2010,Tsinghua University
1.LiangZhang,associate fellow
2.Doctor,D,2010,Tsinghua University