Fatima Ali Al Amer

Dr. Fatima Ali Al Amer


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MAMaryam Alwabari
Maryam Alwabari
FAFatimah Alhamad
Fatimah Alhamad
FAFatimah Ahmed Alsahaf
Fatimah Ahmed Alsahaf
FAFatima Ali Al Amer
Fatima Ali Al Amer
FAFatma Alniniya
Fatma Alniniya
KHALED Ahmed YASSENKHALED Ahmed YASSEN
KHALED Ahmed YASSEN
Preoperative assessment of hemoglobin concentration in blood is important to diagnose anemia. The primary aim of this prospective diagnostic test accuracy study was to monitor non-invasive spectrophotometric hemoglobin (SpHb, g/dL) concentrations among adults prior to elective surgery and to investigate the correlation and agreement of SpHb with laboratory hemoglobin (Hb, g/dl). A secondary aim was to identify the anemia cut-off values for SpHb based on the World Health Organization (WHO) definitions for anemia. This study included 151 consecutive patients (age ≥ 18 year) presenting for preoperative evaluation prior to scheduled elective general or orthopedic surgery. Results identified the mean ± SD of SpHb at 11.43 ± 2.01 g/dL, which underestimated the mean laboratory Hb (12.64 ± 2.29 g/dL, p < 0.001). A bias mean difference (SpHb–Hb) of −1.21 g/dL, with a SD of 1.76, was reported. This bias (SpHb–Hb) was inversely correlated with the mean Hb concentrations. A positive correlation existed between SpHb and Hb, with a good degree of reliability and a significant Intra Class Correlation (ICC). SpHb diagnosed anemia in 32.3% and 60.3% of males and females, respectively. The SpHb cut-off values to identify anemia were 11.3 and 10.2 g/dL for males and females, respectively, with a sensitivity of 83.3% for males and only 62.9% for females. The specificity for males and females were 81% and 91.3%, respectively. SpHb sensitivity allows for anemia diagnosis among males, but not females. However, the specificity allows SpHb to rule out anemia for both.

5 December 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KHALED Ahmed YASSENKHALED Ahmed YASSEN
KHALED Ahmed YASSEN
NENawal Eltaib
Nawal Eltaib
FAFatimah Ahmed Alsahaf
Fatimah Ahmed Alsahaf
FAFatima Ali Al Amer
Fatima Ali Al Amer
FAFatimah Alhamad
Fatimah Alhamad
MAMaryam Alwabari
Maryam Alwabari
Patients with sickle cell disease (SCD) require repeated blood sampling for hemoglobin (Hb) concentration measurements. The primary aim of this study was to compare non-invasive spectrophotometric hemoglobin (SpHb, g/dL) measurements to those taken via an automated hematology analyzer (Hb, g/dL) in patients with SCD visiting outpatient clinics and to investigate the correlations and agreements between both measurement techniques. Secondarily, we aimed to identify the SpHb cut-off concentration for the diagnosis of anemia and to monitor the effects of the pleth variability index (PVI, %) and perfusion index (PI) on SpHb measurements. The results gained from the examination of one hundred and fifty-eight patients indicated that the SpHb measurements overestimated the lab Hb concentrations, with a mean (SpHb-Hb) bias of 0.82 g/dL (SD 1.29). The SpHb measurements were positively correlated with the Hb measurements (Kendall’s tau correlation (τ), n = 158, τ = 0.68, p < 0.001), with an intra-class correlation (ICC) of 0.67 and a 95% CI from 0.57 to 0.74 (p = 0.000). The SpHb cut-off concentration to diagnose anemia was 11.4 and 11.7 g/dL for males and females, respectively. SpHb sensitivity was low for males and females at 64.4% and 57.1%; however, the specificity was higher at 90.9% and 75%, with positive predictive values (PPVs) of 95.6 and 85.7, respectively. No correlation existed between SpHb measurements and the PVI (%) in contrast with a moderate correlation with the PI (r = 0.049, p = 0.54, and r = 0.36, p < 0.001, respectively). The mean PI was low at 2.52 ± 1.7. In conclusion, the SpHb measurements were consistently higher than the lab Hb concentrations, with a positive correlation. The sensitivity and precision of the SpHb measurements were lower than expected. However, the SpHb specificity and its positive predictive values (PPVs) indicated that it is less likely for a patient with a positive SpHb test result for anemia to be non-anemic. These results will allow SpHb measurement to play a role in excluding the presence of anemia. In light of the low PI values determined, the SpHb measurements were challenging to take and, thus, require further technological improvements.