Objective: To describe a method to display the three‐dimensional distribution of intraosseous arteries in the femoral head by vascular corrosion casting.Methods: An experimental study was done to expose the intraosseous arteries of the femoral head by a microperfusion corrosion method between January 2021 and May 2021. Specimens were 23 swine femoral heads (12 female specimens and 11 male specimens, where age of swine ranged from 8 to 12 months, and the weight was approximately 150 kg). The femoral heads were microperfused with the vascular casting resin through retinacular arteries, and the bone of the femoral head was dissolved with 50% sodium hydroxide and 10% hydrochloric acid and rinsed under the microscope until the vessel casts were completely exposed. The distribution and anastomosis of the arteries in the femoral head were observed under direct vision and microscopy. The diameter of the artery in the femoral head was measured at 0.5 cm after its entry into the bone of the femoral head with a microscale under the microscope. The number of internal arteries with diameter ≥0.05 mm was counted. The number and diameter of the main trunk of the epiphyseal arteries in the femoral head between male and female swine were compared.Results: The vascular casting specimen of the swine femoral head was successfully produced by using epoxy resin as a casting agent, and the three‐dimensional intraosseous vascular structures were clearly visible. The number of epiphyseal arteries in male and female swine was 8.55 ± 2.15 and 8.83 ± 2.15 (t = −0.31, p = 0.38), respectively. The diameters of the superior epiphyseal arteries in male and female swine were 0.35 ± 0.09 and 0.31 ± 0.08 mm (t = 1.03, p = 0.16), the diameters of the inferior epiphyseal arteries were 0.47 ± 0.05 and 0.49 ± 0.09 mm (t = −0.57, p = 0.29), and the diameters of the anterior epiphyseal arteries were 0.34 ± 0.08 and 0.33 ± 0.13 mm (t = 0.32, p = 0.37). There was no significant difference in the number and diameter of the main trunk of intraosseous arteries between male and female swine (p > 0.05). The main trunk of intraosseous arteries formed an anastomosis in the center of the femoral head. Among 23 swine femoral head samples, three types of intraosseous anastomosis were observed, including 13 (57%) posterior superior‐posterior inferior, seven (30%) posterior inferior‐anterior, and three (13%) uniform intraosseous anastomosis.Conclusion: The microperfusion corrosion method can produce the vascular casting specimen of swine femoral head revealing the three‐dimensional structure of the intraosseous artery, which clearly shows the origin, course and branches, and diameter, as well as the anastomosis, of nutrient arteries in the femoral head. This method provides a simple and rapid technique for quantifying and visualizing intraosseous arteries.
10 October 2022 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Digital necrosis (DN) is a critical postoperative complication following finger replantation surgery. This can necessitate additional surgical interventions that can adversely affect the patient's hand functionality, psychological well-being, and financial standing. The timely identification and management of the risk of post-replantation DN are thus crucial for enhancing patient outcomes. The objective of this study was to create and validate an easily understandable machine learning (ML) model for predicting the risk of DN following finger replantation surgery. Data from 1579 patients who underwent finger replantation surgery at Suzhou Ruihua Orthopaedic Hospital between September 2018 and September 2023 were collected and divided into training and internal validation sets. Additionally, 293 data points from two other institutions were employed as independent external validation sets. Ten machine-learning methods, including Gradient Boosting Machine (GBM), were utilized for modeling. The performance of the model was assessed using the area under the receiver operating characteristic curve (AUC) and decision curve analysis (DCA). SHapley Additive exPlanation (SHAP) was utilized to provide both global and local interpretations of the final model. Nine indices, including the seniority of the doctor and the neutrophil count, were identified as independent predictors of DN. The GBM model showed optimal model with high predictive accuracy for DN risk in both the training set (AUC: 0.995) and the internal validation set (AUC: 0.978), which was confirmed using external validation (AUC: 0.983). The reliability and utility of the GBM model and the web-based computing platform were confirmed by DCA, calibration curve, accuracy, and sensitivity analyses. An interpretable machine-learning model based on complete blood counts and related inflammatory marker levels was constructed and validated to predict the likelihood of developing DN following finger replantation. This model can assist clinicians in the prompt identification of high-risk patients post-replantation, enabling timely intervention.
13 June 2023 in Journal of Plastic, Reconstructive & Aesthetic Surgery