Jeoung Woo Nam

Jeoung Woo Nam


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JNJeoung Woo Nam
Jeoung Woo Nam
JLJong Hoon Lee
Jong Hoon Lee
HZHaowei Zhang
Haowei Zhang
MSMi Sun Sung
Mi Sun Sung
SPSang-Woo Park
Sang-Woo Park
This study aimed to compare the efficacies and safety of enhanced and standard monofocal intraocular lenses (IOLs) in eyes with early glaucoma. Patients with concurrent cataracts and open-angle glaucoma (OAG) were enrolled. They underwent cataract surgery with IOL implantation. The comprehensive preoperative ophthalmic examination included the manifest refraction; monocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), and uncorrected near visual acuity (UNVA); visual field (VF); and contrast sensitivity (CS); defocus curves and questionnaires were assessed three months postoperatively. Totals of 34 and 38 patients had enhanced and standard monofocal IOLs, respectively. The enhanced monofocal IOL provided better UIVA than the standard monofocal IOL (p = 0.003) but similar UDVA, CDVA, and UNVA. The enhanced monofocal IOL had more consistent defocus curves than the standard monofocal IOL, especially at −1 (p = 0.042) and −1.5 (p = 0.026) diopters. The enhanced monofocal IOL provided better satisfaction (p = 0.019) and lower spectacle dependence (p = 0.004) than the standard monofocal IOL for intermediate vision, with similar VF and CS outcomes. In conclusion, enhanced monofocal IOLs are recommended for patients with OAG because they provide better intermediate vision, higher satisfaction, and lower dependence on spectacles than standard monofocal IOLs, without worsening other visual outcomes.

28 July 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
JNJeoung Woo Nam
Jeoung Woo Nam
JLJong Hoon Lee
Jong Hoon Lee
HZHaowei Zhang
Haowei Zhang
MSMi Sun Sung
Mi Sun Sung
SPSang-Woo Park
Sang-Woo Park
This study aimed to compare the efficacies and safety of enhanced and standard monofocal intraocular lenses (IOLs) in eyes with early glaucoma. Patients with concurrent cataracts and open-angle glaucoma (OAG) were enrolled. They underwent cataract surgery with IOL implantation. Manifest refraction; monocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), and uncorrected near visual acuity (UNVA); visual field (VF); contrast sensitivity (CS); defocus curves and questionnaires were assessed three months postoperatively. Thirty-four and 38 patients had enhanced and standard monofocal IOLs, respectively. The enhanced monofocal IOL provided better UIVA than the standard monofocal IOL (p = 0.003) but similar UDVA, CDVA and UNVA. The enhanced monofocal IOL had more consistent defocus curves than the standard monofocal IOL, especially at -1 (p = 0.042) and -1.5 (p = 0.026) diopters. The enhanced monofocal IOL provided better satisfaction (p = 0.019) and lower spectacle dependence (p = 0.004) than the standard monofocal IOL for intermediate vision, with similar VF and CS. In conclusion, the enhanced monofocal IOL is recommended for patients with OAG because they provide better intermediate vision, higher satisfaction, and lower dependence on spectacles than standard monofocal IOL, without worsening other visual outcomes.