Tibor Szük

Dr. Tibor Szük

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
BTBalázs Tar
Balázs Tar
AAAndras Agoston
Andras Agoston
ÁÜÁron Üveges
Áron Üveges
GSGabor Tamas Szabo
Gabor Tamas Szabo
TSTibor Szük
Tibor Szük
ZKZsolt Kőszegi
Zsolt Kőszegi
Purpose: To develop a method of coronary flow reserve (CFR) calculation derived from three-dimensional (3D) coronary angiographic parameters and intracoronary pressure data during fractional flow reserve (FFR) measurement. Methods: Altogether 19 coronary arteries of 16 native and 3 stented vessels were reconstructed in 3D. The measured distal intracoronary pressures were corrected to the hydrostatic pressure based on the height differences between the levels of the vessel orifice and the sensor position. Classical fluid dynamic equations were applied to calculate the flow during the resting state and vasodilatation based on morphological data and intracoronary pressure values. 3D-derived coronary flow reserve (CFRp-3D) was defined as the ratio between the calculated hyperemic and the resting flow and was compared to the CFR values simultaneously measured by the Doppler sensor (CFRDoppler). Results: Haemodynamic calculations using the distal coronary pressures corrected for hydrostatic pressures showed a strong correlation between the individual CFRp-3D values and the CFRDoppler measurements (r = 0.89, p < 0.0001). Hydrostatic pressure correction increased the specificity of the method from 46.1% to 92.3% for predicting an abnormal CFRDoppler < 2. Conclusions: CFRp-3D calculation with hydrostatic pressure correction during FFR measurement facilitates a comprehensive hemodynamic assessment, supporting the complex evaluation of macro-and microvascular coronary artery disease.

1 January 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
BNBalázs Tamás Németh
Balázs Tamás Németh
IHIstvan Hizoh
Istvan Hizoh
FNFanni Nowotta
Fanni Nowotta
Zoltán RuzsaZoltán Ruzsa
Zoltán Ruzsa
TSTibor Szük
Tibor Szük
IÉIstván F. Édes
István F. Édes
Although radial access is the current gold standard for the implementation of percutaneous coronary interventions (PCI), post-procedural radial compression devices are seldom compared with each other in terms of safety or efficacy. Our group aimed to compare a cost effective and potentially green method to dedicated radial compression devices, with respect to access site complications combined in a device oriented complex endpoint (DOCE), freedom from which served as our primary endpoint. Patients undergoing PCI were randomized to receive either the cost effective or a dedicated device, either of which were removed using patent hemostasis. Twenty-four hours after the procedure, radial artery ultrasonography was performed to evaluate the access site. The primary endpoint was assessed using a non-inferiority framework with a non-inferiority margin of five percentage points, which was considered as the least clinically meaningful difference. The cost-effective technique and the dedicated devices were associated with a comparably low rate of complications (freedom from DOCE: 83.3% vs. 70.8%, absolute risk difference: 12.5%, one-sided 95% confidence interval (CI): 1.11%). Composition of the DOCE (i.e., no complication, hematoma, pseudoaneurysm, and radial artery occlusion) and compression time were also assessed in superiority tests as secondary endpoints. Both the cost-effective technique and the dedicated devices were associated with comparably low rates of complications: p = 0.1289. All radial compression devices performed similarly when considering the time to complete removal of the respective device (120.0 (inter-quartile range: 100.0–142.5) for the vial vs. 120.0 (inter-quartile range: 110.0–180) for the dedicated device arm, with a median difference of [95% CI]: 7.0 [−23.11 to 2.00] min, p = 0.2816). In conclusion, our cost-effective method was found to be non-inferior to the dedicated devices with respect to safety, therefore it is a safe alternative to dedicated radial compression devices, as well as seeming to be similarly effective.

23 July 2022 in Thrombosis Research
Verified
Journal Article
Closed access
ÁIÁdám Illési
Ádám Illési
IDIldikó Beke Debreceni
Ildikó Beke Debreceni
ZFZsolt Fejes
Zsolt Fejes
BNBéla Nagy
Béla Nagy
KHKatalin Hodosi
Katalin Hodosi
TSTibor Szük
Tibor Szük

29 October 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ÁIÁdám Illési
Ádám Illési
ZFZsolt Fejes
Zsolt Fejes
MPMarianna Pócsi
Marianna Pócsi
IDIldikó Beke Debreceni
Ildikó Beke Debreceni
KHKatalin Hodosi
Katalin Hodosi
TSTibor Szük
Tibor Szük
Percutaneous coronary intervention (PCI) is a frequently performed treatment option for recanalization in patients with chronic total occlusion (CTO). As CTO-PCIs are often complicated and challenging for interventionalists, the stressful and damaging nature of the procedure can be remarkable, thus platelets can be easily activated. Our aim was to investigate the effect of CTO-PCI on platelet activation and the expression of selected circulating microRNAs (miR) of platelet and endothelium origin after CTO-PCI. In this study, 50 subjects after CTO-PCI were enrolled. Blood samples were obtained before PCI, at 2 days and 3–6 months after the procedure to measure the degree of platelet activation and the level of plasma miR-223, miR-181b, and miR-126. Patients were divided based on the characteristics of the intervention. Patients with higher Japanese CTO scores and longer duration of PCI showed significantly elevated platelet P-selectin positivity (p = 0.004 and p = 0.013, respectively) 2 days after the procedure compared to pre-PCI and increased concentration of soluble P-selectin 3–6 months after the intervention (higher Japanese CTO score: p = 0.028 and longer duration of PCI: p = 0.023) compared to baseline values. Shorter total stent length caused a significantly lower miR-181b expression at 3–6 months after the intervention (p = 0.031), while no difference was observed in miR-223 and miR-126. One stent thrombosis occurred during the follow-up period. Although these technically challenging CTO-PCIs may cause enhanced platelet activation right after the intervention and long-term endothelial cell dysfunction, these interventions are not associated with more adverse clinical events.