The CASBEE‐Wellness Office (hereinafter CASBEE‐WO) was launched in June 2019 as a new CASBEE tool for assessing buildings and workplaces from the viewpoints of workers' health, workplace productivity, and resilience. In this paper, we introduce the structure of the evaluation system. The tool development has begun in response to emerging demands following recent social movements related to PRI and ESG investments. The new tool has added a function that evaluates wellness factors in the building evaluation process using the CASBEE family. While CASBEE‐WO can be used alone, the simultaneous evaluation with existing CASBEE tools can be selected. Two types of new building certifications are launched. The “Wellness Office” is the one certified with CASBEE‐WO alone, and the “Smart Wellness Office” is the simultaneous certification with the existing CASBEE tools. The technical background, such as the correlations with other evaluation tools, CASBEE‐OHC and WFun, is also explained. It shows that the CASBEE‐WO can properly evaluate buildings providing a work environment to reduce the risk of a high work functioning impairment. The third‐party certification process has been started, and the data are analyzed. The new version was released in May 2020 to fix some defects found through the analysis.
To achieve the desired free-cooling effect, the preliminary design of natural ventilation should be combined with discussions of building shape during the early design stages. In an earlier study a method for supporting strategic design of natural ventilation was developed that relied on the target air change rate and natural ventilation potential. The authors defined target air change rate as a point where the gradient of the increase in the cooling effect from natural ventilation reached a maximum. To verify the viability of the proposed method, the robustness of the target air change rate is examined in this paper using a typical Chinese office building model with representative operation conditions in five climate zones of China. The impacts of insulation level, thermal capacity, and window-to-wall ratio (WWR) on the target air change rate are investigated. In addition, the target air change rate and natural ventilation potential maps in China are created to inform rough natural ventilation strategies in the early design stages. According to the evaluation results, simple natural ventilation strategies are sufficient for buildings with relatively low internal gains to realize the required small target air change rate, regardless of climate conditions. Under moderate internal gains condition, well-organized and examined natural ventilation strategies are required in the Hot Summer and Warm Winter zone and the Temperate zone. However, these strategies are particularly suggested for cities in the Temperate zone with a warm climate due to the higher cooling potential. Moreover, elaborate natural ventilation design is recommended for buildings in cold climates when the internal gains are increased to a high level.
This study investigates the effect of a perforated sheet combined with a double‐skin facade (DSPF) by varying the important building parameters, such as perforation percentage, facade orientation, and the thickness of the double‐skin facade (DSF). This study determines the energy‐saving, natural ventilation, and daylight performance of an office building in Tokyo, Japan by conducting simulations. This study discovers that the DSPF thickness does not influence the performances much and the DSPF thickness of 0.5 m is recommended. For daylighting, the system with the 40% perforation percentage on the south and 10% perforation percentage on the west is the best case of daylight access without disturbing glare in the particular view of this study. To balance natural ventilation and daylight when installing perforated screens, this research demonstrated the net heat removal in spring when the perforated percentage of 50% on the south and 30% on the west is recommended. In autumn, the net heat removal when the perforated percentage of 10% on the south and 30% on the west is recommended. This research demonstrated that the total net heat removal when the perforated percentage of 10% on the south and 30% on the west are recommended for removing heat throughout a year.