Jean-Christophe Lapayre

Jean-Christophe Lapayre

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Expert Systems with Applications
Verified
Journal Article
Closed access
FMFlorent Marie
Florent Marie
LCLisa Corbat
Lisa Corbat
YCYann Chaussy
Yann Chaussy
TDThibault Delavelle
Thibault Delavelle
JHJulien Henriet
Julien Henriet
Jean-Christophe LapayreJean-Christophe Lapayre
Jean-Christophe Lapayre

12 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
DLDonatien Legé
Donatien Legé
LGLaurent Gergelé
Laurent Gergelé
MPMarion PRUDHOMME
Marion PRUDHOMME
Jean-Christophe LapayreJean-Christophe Lapayre
Jean-Christophe Lapayre
YLYoann Launey
Yoann Launey
JHJulien Henriet
Julien Henriet
The intracranial pressure (ICP) signal, as monitored on patients in intensive care units, contains pulses of cardiac origin, where P1 and P2 subpeaks can often be observed. When calculable, the ratio of their relative amplitudes is an indicator of the patient’s cerebral compliance. This characterization is particularly informative for the overall state of the cerebrospinal system. The aim of this study is to develop and assess the performances of a deep learning-based pipeline for P2/P1 ratio computation that only takes a raw ICP signal as an input. The output P2/P1 ratio signal can be discontinuous since P1 and P2 subpeaks are not always visible. The proposed pipeline performs four tasks, namely (i) heartbeat-induced pulse detection, (ii) pulse selection, (iii) P1 and P2 designation, and (iv) signal smoothing and outlier removal. For tasks (i) and (ii), the performance of a recurrent neural network is compared to that of a convolutional neural network. The final algorithm is evaluated on a 4344-pulse testing dataset sampled from 10 patient recordings. Pulse selection is achieved with an area under the curve of 0.90, whereas the subpeak designation algorithm identifies pulses with a P2/P1 ratio > 1 with 97.3% accuracy. Although it still needs to be evaluated on a larger number of labeled recordings, our automated P2/P1 ratio calculation framework appears to be a promising tool that can be easily embedded into bedside monitoring devices.

1 January 2013 in Integrated Computer-Aided Engineering
Verified
Journal Article
Open access
PDF file
RKR. Kassab
R. Kassab
Jean-Christophe LapayreJean-Christophe Lapayre
Jean-Christophe Lapayre
JAJ.-B. Aupet
J.-B. Aupet
Franck MarzaniFranck Marzani
Franck Marzani
CPC. Pieralli
C. Pieralli
Telemedicine has been developed to allow practitioners to remotely connect with patients and with other medical staff. We propose a new system (hardware and software), named DICODERM (COllaborative DIagnosis of DERMatosis), which makes it possible to

6 June 2023 in Preprints.org
Verified
Preprint
Open access
DLDonatien Legé
Donatien Legé
LGLaurent Gergelé
Laurent Gergelé
MPMarion Prud'HOmme
Marion Prud'HOmme
Jean-Christophe LapayreJean-Christophe Lapayre
Jean-Christophe Lapayre
YLYoann Launey
Yoann Launey
JHJulien Henriet
Julien Henriet
The intracranial pressure (ICP) signal, as monitored on patients in intensive care units, contains pulses of cardiac origin where P1 and P2 subpeaks can often be observed. When calculable, the ratio of their relative amplitudes is an indicator of the patient’s cerebral compliance. This characterization is particularly informative on the overall state of the cerebrospinal system. We developed a recurrent neural network-based framework for P2/P1 ratio computation that only takes a raw ICP signal as an input. Two tasks are performed, namely pulse classification and subpeak designation. Pulse classification was achieved with an area under the curve of 0.90 on a 4,344-pulse testing dataset, while the peak designation algorithm identified pulses with a P2/P1 ratio > 1 with a 97.3% accuracy. Although it still needs to be evaluated on a larger number of labeled recordings, our automated P2/P1 ratio calculation framework appears to be a promising tool for improving bedside monitoring devices.