Xiaoke Liu

Dr. Xiaoke Liu

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2018 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
XLXiaoke Liu
Xiaoke Liu
JPJames Palmer
James Palmer

28 December 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
JCJingjing Chen
Jingjing Chen
FEFatima M Ezzeddine
Fatima M Ezzeddine
XLXiaoke Liu
Xiaoke Liu
FMFreddy Del-Carpio Munoz
Freddy Del-Carpio Munoz
PFPaul Friedman
Paul Friedman
YCYong-Mei Cha
Yong-Mei Cha
Artificial intelligence (AI)-enabled electrocardiogram (ECG) has proved to be a valuable screening tool for identifying individuals with reduced left ventricular ejection fraction (LVEF).1 At Mayo Clinic, we have successfully developed and integrated an AI algorithm into our 12-lead ECG dashboard, facilitating early and non-invasive detection of reduced LVEF.2–4 The objective of this report was to apply our recently developed AI-ECG algorithm in patients who underwent left bundle branch area pacing (LBBAP) to predict cardiac resynchronization therapy (CRT) outcomes in patients with heart failure and reduced ejection fraction (LVEF ≤ 50%).

9 November 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ZLZhigang Liu
Zhigang Liu
XLXiaoke Liu
Xiaoke Liu
Background: Left bundle branch area pacing (LBBAP) has rapidly emerged as a promising modality of physiologic pacing and has demonstrated excellent lead stability. In this retrospective study, we evaluate whether this pacing modality can allow concomitant atrioventricular node (AVN) ablation and same-day dismissal. Methods: Twenty-four consecutive patients (female 63%, male 37%) with an average age of 78 ± 5 years were admitted for pacemaker (75%)/defibrillator (25%) implantations and concomitant AVN ablation. Device implantation with LBBAP was performed first, followed by concomitant AVN ablation through left axillary vein access to allow for quicker post-procedure ambulation. The patients were discharged on the same day after satisfactory post-ambulation device checks. Results: LBBAP was successful in 22 patients (92% in total, 20 patients had an LBBP and two patients had a likely LBBP), followed by AVN ablation from left axillary vein access (21/24, 88%). All patients had successful post-op chest x-rays, post-ambulation device checks, and were discharged on the same day. After a mean follow up of three months, no major complications occurred, such as LBBA lead dislodgement requiring a lead revision. The LBBA lead pacing parameters immediately after implantation vs. three-month follow up were a capture threshold of 0.8 ± 0.3 V@0.4 ms vs. 0.6 ± 0.3 V@0.4 ms, sensing 9.9 ± 3.9 mV vs. 10.4 ± 4.1 mV, and impedance of 710 ± 216 ohm vs. 544 ± 110 ohm. The QRS duration before and after AVN ablation was 117 ± 32 ms vs. 123 ± 14 ms. Mean LVEF before and three months after the implantation was 44 ± 14% vs. 46 ± 12%. Conclusion: LBBA pacing not only offers physiologic pacing, but also allows for a concomitant AVN ablation approach from the left axillary vein and safe same-day hospital dismissal.

30 August 2022 in HeartRhythm Case Reports
Verified
Journal Article
Open access
PDF file
ZLZhigang Liu
Zhigang Liu
XLXiaoke Liu
Xiaoke Liu
Recent advances in the electroanatomic mapping (EAM) have drastically reduced radiation exposure related to EP procedures and made it feasible to perform cardiac ablation with zero-fluoroscopy exposure. Ferguson J.D. Helms A. Mangrum J.M. et al. Catheter ablation of atrial fibrillation without fluoroscopy using intracardiac echocardiography and electroanatomic mapping. Circulation: Arrhythmia and electrophysiology. 2009; 2 : 611-619 Crossref PubMed Scopus (0) Google Scholar , Liu X. Palmer J. Outcomes of 200 consecutive, fluoroless atrial fibrillation ablations using a new technique. Pacing and clinical electrophysiology :PACE. 2018; 41 : 1404-1411 Crossref PubMed Scopus (0) Google Scholar However, significant radiation exposure during cardiac implantable electrical device (CIED) procedures remains a major potential occupational hazard to the operators. National Research Council (US) Board on Radiation Effects Research. Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII, Phase I, Letter Report (1998). Washington (DC): National Academies Press (US); 1998. PMID: 25077203.. Google Scholar Complex CIED procedures, especially cardiac resynchronization therapy (CRT) devices, entail more radiation exposure and thus may pose higher health risk.

31 July 2024 in Heart Rhythm
Verified
Journal Article
Closed access
FMFreddy Del-Carpio Munoz
Freddy Del-Carpio Munoz
SMSiva Mulpuru
Siva Mulpuru
ELErin Luethe
Erin Luethe
CCCaitlin Carpenter
Caitlin Carpenter
CCCharles Cagin
Charles Cagin
XLXiaoke Liu
Xiaoke Liu