Objective: The aim of our study is to investigate the effect of percussion massage applied to the quadriceps muscle with a Hypervolt device on range of motion (ROM), jumping, agility and anaerobic performance. Material and Methods: Total of 24 (41.7% female, 58.3% male) healthy individuals with mean age of 22.04±1.19 years participated in the study. A cross-randomization method with a 72-hour washout period was used throughout the study. Percussion massage (Hyperice, California, USA) was applied to the dominant quadriceps muscle of the participants lying in the supine position for 8 minutes at a frequency of 30 Hz using the flat head of the Hypervolt device. ROM, vertical jump, T Drill Test and Wingate anaerobic performance tests (WAnT) were evaluated. Results: Hip flexion ROM of the participants increased significantly after percussion massage with Hypervolt (p=0.02). There was no significant difference in vertical jump and T Drill Test results and ROM measurements other than hip flexion after percussion massage with Hypervolt (p˃0.05). WAnT results were found to be decreased (p<0.05). Conclusion: While percussion massage device has positive effects on joint range of motion, they have no effect on jumping and agility performance. However, there was a decrease in anaerobic power output. Percussion devices such as Hypervolt which are utilized for warming up may reduce anaerobic performance.
Objective: In this study, it was aimed to examine the effects of knee brace use on landing error after jumping, balance and crossover hop test (CHT) in healthy athletes. Methods: After recording the descriptive information of the healthy volunteer athletes and measuring the lower extremity joint range of motion, and the Q angle at the knee, participants were randomized. During the study, randomization was carried out as follows: those who did not use knee braces (GroupNon), those who used simple knee braces (GroupBasic) and those who used ligament-supported knee braces (GroupLig). Y-balance test of lower extremity (YBTL), CHT, and landing error scoring after jumping were applied to the participants. Results: A total of 56 professional athletes (GroupNon, n=19; GroupBasic, n=19; GroupLig, n=18) participated in the study. Characteristics of the participants did not reveal any difference (p>0.05). Compared with the other two groups, lower hip extension range of motion was observed in GroupNon (p˂0.05), and no difference was observed in other lower extremity descriptive data (p>0.05). Furthermore, comparing to the other two groups, a significant (p=0.014) increase was observed only in the velocity of CHT applied to the non-dominant extremity of GroupBasic. No significant difference was observed in the other evaluated parameters (p>0.05). As a result of intra-group correlation analyses, different levels of relationship were determined between the landing results after the jumping and various biomechanical properties according to the choice of knee brace (p˂0.05). Conclusion: It would be appropriate to choose the knee brace to be used in healthy athletes by taking into account the biomechanical defining characteristics of the athlete.
This study aims to investigate the Turkish validity and reliability of the International Fitness Scale (IFIS) and the Self-Perceived Health-Related Physical Fitness Questionnaire for Children (SPHQ-C) aged 10–17. The measurement tools were translated into Turkish by two independent researchers and back-translated. Then, the content validity was established with a group of 13 individuals (Sample 1) who presented to the sports medicine clinic. The pilot application phase was initiated. A sample of 372 individuals (Sample 2) studying in the provincial center was selected for piloting the measurement tools with the ALPHA-FIT Test Battery. The test–retest application of the measurement tools with a 15-day interval was carried out with 207 individuals (Sample 3) not included in Sample 2. The authors calculated that the content validity ratio values for the items in the IFIS ranged from 0.85 to 1.00, with a content validity index of 0.94 for the scale. In the SPHQ-C, these values were found to be between 0.92 and 1.00, with a content validity index of 0.99. According to the Z-score difference analysis for both measurement tools, the construct validity of all items was achieved (p < 0.05). In the Bland–Altman plot test conducted for the IFIS-TR, the mean difference was calculated as 0.11, the standard deviation of the differences was 1.57, and the p-value was determined as 0.31. For the SPHQ-C-TR, the mean difference was −0.15, the standard deviation of the differences was 1.95, and the p-value was determined as 0.26. The Kappa coefficients for the items of the IFIS-TR ranged from 0.45 to 0.52, while for the SPHQ-C-TR, the Kappa coefficients ranged from 0.47 to 0.75. Confirmatory factor analysis conducted on Sample 2 confirmed model fit indices with covariance among some items of the measurement tools (IFIS-TR: e1–e3; SPHQ-C-TR: e1–e2, e1–e3, e2–e3, e3–e4, e6–e7, e8–e9). The IFIS and SPHQ-C measurement tools have been adapted into Turkish, and their validity and reliability have been established.
Amaç Halat egzersizleri, fiziksel performansı artırmak için geniş çaplı ve ağır halatların kullanıldığı pliyometrik egzersiz yaklaşımıdır. Kürek egzersizleri ise genel vücut kuvvetini artıran, kapalı ortamda kürek çekme aletiyle yapılan bir egzersiz türüdür. Çalışmanın amacı, bu iki egzersiz yaklaşımının omzun internal rotasyon/ eksternal rotasyon (IR/ER) kas kuvvetine, propriyosepsiyonuna, üst ekstremite dengesine, alt ekstremite kuvveti ve gövde stabilizasyonuna etkilerinin karşılaştırılmasıdır. Gereç ve Yöntem Araştırmaya, 18-25 yaşları aralığında sağlıklı 22 birey dahil edilmiştir. Çalışma başlangıcında ve sonunda; 60°/sn açısal hızdaki izokinetik dinamometre ile IR/ ER omuz kas kuvvet testi, izokinetik dinamometre ile 15°, 45° ve 75° hedef açılarda aktif IR/ER omuz propriyosepsiyon ölçümü, üst ekstremite için Y denge testi ve kapalı kinetik zincir alt ekstremite stabilite testi gerçekleştirilmiştir. Katılımcılar randomize olarak kürek (n=10) ve halat (n=12) egzersiz gruplarına ayrılmıştır. Her iki gruba da 6 hafta boyunca, haftada 3 gün, gün aşırı, 6 set egzersiz ve setler arasında 30 sn dinlenmeyle egzersizler yapılmıştır. Egzersizler sırasındaki ritmi takip edebilmek için halat egzersiz grubunda 60 bpm, kürek grubunda 30 bpm metronom hızı belirlenmiştir. Bulgular Egzersiz programlarından sonra; her iki grubun da (Kürek; n=9 / Halat; n=10) başlangıca göre kapalı kinetik zincir alt ekstremite stabilite testi ve IR total iş sonucunda anlamlı artış bulunmuş (p˂0,05), Üst Ekstremite Y Denge Testi ve propriyosepsiyon testi sonuçlarında fark olmadığı görülmüştür (p˃0,05). Halat egzersizi grubunun; dominant omzunun 60˚/s hızındaki IR zirve torku (p=0,048) ve vücut ağırlığına oranı (p=0,045) egzersiz programının sonunda, başlangıca göre anlamlı olarak artmıştır. Egzersiz programı- nın başlangıcına göre egzersiz programı sonrasında belirlenen değişim miktarlarının karşılaştırılmasında iki grup arasında birbirine üstünlük gözlenmemiştir (p>0,05). Sonuç Mevcut sonuçlar ışığında iki egzersiz protokolünün de sağlık bireylerde antrenman programlarının bir parçası haline getirilebileceğini düşünmekteyiz.
18 December 2024 in BMC Sports Science, Medicine and Rehabilitation
This study aimed to adapt the Knee injury and Osteoarthritis Outcome Score- Anterior Cruciate Ligament (KOOS-ACL) into Turkish and to assess its validity and reliability. The adaptation process involved translation, back-translation, and cultural adaptation of the questionnaire. Totally 133 patients who had a diagnosis of anterior cruciate ligament tear was recruited. The reliability of the Turkish version of the KOOS-ACL was assessed using Cronbach’s alpha, item-total correlations, and ICC. EFA and CFA were performed to evaluate construct validity, supported by KMO and Bartlett’s test results. Criterion validity was examined through correlations with IKDC scores, and discriminative power was assessed using an independent samples t-test. IKDC score for evaluating knee function was 59.84 ± 21.74. The composite KOOS-ACL-Tr score was 61.95 ± 25.19. Cronbach’s Alpha value was found to be 0.952 demonstrating high reliability. KOOS-ACL-Tr scores showed a linear positive correlation with the time elapsed since injury and IKDC scores (p < 0.001) establishing concurrent validity. The adapted Turkish version of the KOOS-ACL is a valid and reliable scale intended for use in monitoring patients with ACL injuries.
Biyomekanik ve hareket analizi konuları, spor hekimleri tarafından günden güne önemi artan alanlardandır. Hareket analizi sistemleri, farklı hareket paternleri sonucunda biyolojik dokunun etkilenimini incelemekte ve bu etkilenimi verilere dökmektedir. Bu veriler ışığında klinisyen, yaralanma öncesinde ve sonrasında yaralanmanın önlenmesi, tedavisi veya rehabilitasyonu konularında daha efektif yöntemlere başvurabilmektedir. Profesyonel sporcular ve rekreasyonel düzeyde sporla ilgilenen bireyler, sıklıkla fırlatma ve koşma eylemlerini içeren aktivitelere katılmaktadır. Fırlatma eylemi toplamda 4 fazdan oluşmakta ve bu eylem sırasındaki teknik hataların düzeltilmesi özellikle üst ekstremite yaralanmalarının önlenmesinde ve tedavisinde çok büyük önem arz etmektedir. Koşma eylemi ise 5 fazdan oluşmakta ve biyomekanik olarak incelenmesi alt ekstremite yaralanmalarının önlenmesinde ve tedavisinde önemlidir. Bu derlemenin amacı, spor hekimliği pratiğinde sık kullanılan hareket analizi sistemlerinin, üst ekstremite ve alt ekstremite biyomekaniklerinin güncel bilgiler ışığında okuyucuya sunulmasıdır.