Cefquinome has a broad spectrum of antibacterial activity and was developed especially for use in animals. A simple and sensitive high-performance liquid chromatography (HPLC) method with UV-visible detection for quantification of cefquinome concentrations in sheep plasma was developed and validated. Separation of cefquinome from plasma components was achieved on a Phenomenex Gemini C18 column (250 mm by 4.6 mm; internal diameter [i.d.], 5 μm). The mobile phase consisted of acetonitrile and 0.1% trifluoroacetic acid in water and was delivered at a rate of 0.9 ml/min. A simple and rapid sample preparation involved the addition of methanol to 200 μl of plasma to precipitate plasma proteins followed by direct injection of 50 μl of supernatant into the high-performance liquid chromatography system. The linearity range of the proposed method was 0.02 to 12 μg/ml. The intraday and interday coefficients of variation obtained from cefquinome were less than 5%, and biases ranged from −3.76% to 1.24%. Mean recovery based on low-, medium-, and high-quality control standards ranged between 92.0 and 93.9%. Plasma samples were found to be stable in various storage conditions (freeze-thaw, postpreparative, short-term, and long-term stability). The method described was found to be readily available, practicable, cheap, rapid, sensitive, precise, and accurate. It was successfully applied to the study of the pharmacokinetics of cefquinome in sheep. This method can be very useful and an alternate to performing pharmacokinetic studies in the determination of cefquinome for clinical use.
1 May 2016 in American Journal of Veterinary Research
OBJECTIVE To determine the pharmacokinetics of meloxicam after single IV and IM injections in red-eared slider turtles (Trachemys scripta elegans). ANIMALS 8 healthy red-eared slider turtles. PROCEDURES Turtles received 1 dose of meloxicam (0.2 mg/kg) IV or IM (4 turtles/route), a 30-day washout period was provided, and then turtles received the same dose by the opposite route. Blood samples were collected at predetermined times for measurement of plasma meloxicam concentration. Pharmacokinetic values for each administration route were determined with a 2-compartment open model approach. RESULTS For IV administration, mean ± SD values of major pharmacokinetic variables were 1.02 ± 0.41 hours for distribution half-life, 9.78 ± 2.23 hours for elimination half-life, 215 ± 32 mL/kg for volume of distribution at steady state, 11.27 ± 1.44 μg•h/mL for area under the plasma concentration versus time curve, and 18.00 ± 2.32 mL/h/kg for total body clearance. For IM administration, mean values were 0.35 ± 0.06 hours for absorption half-life, 0.72 ± 0.06 μg/mL for peak plasma concentration, 1.5 ± 0.0 hours for time to peak concentration, 3.73 ± 2.41 hours for distribution half-life, 13.53 ± 1.95 hours for elimination half-life, 11.33 ± 0.92 μg•h/mL for area under the plasma concentration versus time curve, and 101 ± 6% for bioavailability. No adverse reactions were detected. CONCLUSIONS AND CLINICAL RELEVANCE Long half-life, high bioavailability, and lack of immediate adverse reactions of meloxicam administered IM at 0.2 mg/kg suggested the possibility of safe and effective clinical use in turtles. Additional studies are needed to establish appropriate administration frequency and clinical efficacy.
12 June 2019 in Journal of Veterinary Pharmacology and Therapeutics
The purpose of this study was to compare the pharmacokinetics, tissue residues, and withdrawal times of doxycycline after oral administration in rainbow trout reared at 10 and 17 °C. Fish received a 20 mg/kg oral dose of doxycycline after a single or 5-day administration. Six rainbow trout were used at each sampling time point for plasma and tissue samples, including liver, kidney, and muscle and skin. The doxycycline concentration in the samples was determined using high-performance liquid chromatography with ultraviolet detector. The pharmacokinetic data were evaluated by non-compartmental kinetic analysis. The WT 1.4 software program was used to estimate the withdrawal times. The increase of temperature from 10 to 17 °C shortened the elimination half-life from 41.72 to 28.87 h, increased the area under the concentration–time curve from 173.23 to 240.96 h * μg/mL, and increased the peak plasma concentration from 3.48 to 5.50 μg/mL. At 10 and 17 °C, the doxycycline concentration was obtained in liver > kidney > plasma > muscle and skin. According to the MRL values stated for muscle and skin in Europe and China (100 μg/kg) and in Japan (50 μg/kg), the withdrawal times of doxycycline at 10 and 17 °C were 35 and 31 days, respectively, for Europe and China and 43 and 35 days, respectively, for Japan. Since temperature significantly affected pharmacokinetic behavior and withdrawal times of doxycycline in rainbow trout, temperature-dependent dosing regimens and withdrawal times of doxycycline might be necessary.
25 November 2018 in Journal of Veterinary Pharmacology and Therapeutics
The administration of high doses of non-steroidal anti-inflammatory drugs (NSAID), such as tolfenamic acid (TA), has undesirable effects on different organs. Some novel biomarkers have been reported that can determine the gastrointestinal and renal injury caused by a high dose of NSAIDs or other toxic substances. This study was aimed at determining the changes in gastrointestinal (TFF2 and HYP), renal (NGAL and KIM-1) and cardiac (cTn-I, CK-MB) injury markers after the use of increasing intravenous doses of TA in sheep. TA was administered intravenously to groups of six sheep each, at the dose levels of 0 (Group 0, i.e., G0), 2 (G2), 4 (G4), 8 (G8) and 16 (G16) mg/kg. The concentrations of the studied biomarkers were measured at 3, 9, 18 and 36 h after administration of TA. The TFF2 and NGAL concentrations in G16 were found to be significantly higher (P < 0.05) than in the other groups except for G8 at different sampling times. HYP concentration in G16 was observed to be significantly (P < 0.05) lower than that in all other groups at 36 h. KIM-1 level in G16 was significantly (P < 0.05) higher than in all other groups at different sampling times. An increase in the renal markers, KIM-1 and NGAL, in G8 was observed before any change in plasma creatinine and urea. The cardiac marker cTn-I in G16 was significantly (P < 0.05) higher than in other groups at different sampling times. The results showed that the novel biomarkers (HYP, TFF2, NGAL, and KIM-1) can be used to determine gastric and renal injury in sheep.