The octagonal tangentially fired boiler can be utilized for burning lignite with high moisture. Co-firing biomass in an octagonal tangential boiler is considered a promising approach. A numerical simulation is carried out in this study to analyze the impact of flue gas recirculation (FGR) and the biomass blending ratio on heat and mass transfer in an octagonal tangentially fired boiler. When the FGR rate increases from 0 to 30%, the maximum temperature in the boiler decreases from 2162.8 to 2106.5 K. Simultaneously, the average temperature of the center longitudinal section decreases from 1589.0 to 1531.9 K. The maximum fluctuation of the outlet flue gas temperature remains within 10.9 K for the four calculated working conditions. Consequently, the efficiency of the boiler is basically unchanged. However, the flue gas temperature at the furnace outlet decreases significantly from 1605.9 to 1491.9 K. When the biomass blending ratio increases from 0 to 20%, the mean temperature of the primary combustion zone decreases from 1600.5 to 1571.2 K.
Retrofitting a tangentially fired boiler into a slag-tap boiler offers a solution for fully burning high-alkali coal in power plant boilers. Numerical simulation and hydrodynamic calculation of such a retrofit scheme were performed in this study. The maximum temperature in the furnace after retrofitting is 2306.8 K, surpassing the pre-retrofit temperature of 2095.8 K. The average temperature in the combustion chamber of the slag-tap boiler is 2080.3 K, which ensures that the slag can be discharged in a molten state. When the coal consumption is halved relative to the working condition of the boiler maximum continuous rating (BMCR) in the slag-tap boiler, the maximum temperature in the combustion chamber decreases from 2306.8 to 2220.3 K. However, the temperature distribution remains relatively uniform, ensuring that the slag discharge is not disrupted. In both of the working conditions calculated in this study, the fluid flow rates in the water-cold wall are positively correlated with the wall heat fluxes. The maximum wall temperatures under the two working conditions are 653.9 and 590.6 K, respectively, both of which are well within the safe limits for the wall material. The results illustrate the feasibility of the retrofit scheme.
The inherent residual swirl at the furnace outlet of tangentially fired boilers induces severe thermal deviations on high-temperature heating surfaces. To reveal the evolutionary patterns of thermal deviation during peak regulation operation, this study employed a numerical method to analyze the thermal deviation characteristics of high-temperature heating surfaces in a 350 MW tangentially fired boiler under 12 operating conditions (covering 100%, 72%, 50%, and 28% loads). As the load decreases, the average absolute vorticity at the platen bottom plane also decreases. However, its decreasing rate is pretty slow compared with that of the load, indicating that the velocity deviation increases relatively. In addition, the flow field becomes more sensitive to the mill group operation mode. Correspondingly, the thermal deviations of the division platen superheater, rear platen superheater, finishing reheater, and finishing superheater all show an upward trend. When the load decreases from 100% to 28%, the average heat absorption deviations of the four heating surfaces increase to 3.48, 2.06, 1.27, and 1.99 times their original values, respectively. A comparison of the internal operating conditions under four loads shows that activating the lower-layer burners helps to reduce thermal deviation. This study proposes indicators for characterizing and analyzing the thermal deviation of high-temperature heating surfaces and provides general suggestions for the operation of tangentially fired boilers.
The condensing heat exchanger is commonly applied in various heat exchange systems. It can efficiently recover moisture and heat from the flue gas that contains water vapor. However, the convective-condensation heat transfer process is so complicated that no mature thermal calculation model is available. This study develops a thermal calculation model for the widely employed tubular condensing heat exchanger in industry. To characterize the degree of the heat and mass transfer, this study introduces two parameters, namely the sensible and latent heat transfer efficiencies of fin. The thermal calculations are conducted for the condensing heat exchangers reported in the literature to verify the proposed model by comparing it with the experimental data. The results show that the absolute error of the calculated sensible and latent heat transfer efficiencies is 0.0365 and 0.0268, respectively. Under the working conditions in this study, a maximum difference of 5.2 K has been acquired between the measured and calculated values of the outlet temperature. The relative error of the condensate water flowrate is mostly within ±5.0% and ±10.0% under the bare-tube and finned-tube conditions, respectively, with a maximum deviation of 0.7 and 1.4 kg h-1. This study provides a general model for designing and optimizing various tubular condensing heat exchangers accurately.