Effect on maximum loading parameter in power systems of the grid integrated wind turbine relation is important for voltage stability. In this study, the effects on static voltage stability of static impedance, current, and active power (ZIP) load modeling in wind turbine integrated to 11 buses power system are investigated. The impacts of ZIP load modelling on different parameter values were evaluated in terms of voltage-maximum loading parameters. Besides, voltage profile of 11 buses power system with wind turbine connected to different generator buses was examined. With use of wind turbine have shown that static voltage stability is more effective and maximum load parameter value is increased.
In this study, firstly, the balance between the exploration and exploitation capabilities of the weighted mean of vectors (INFO) algorithm was developed using the fitness–distance balance (FDB) method. Then, the FDB-INFO algorithm was developed with a hyper-heuristic method to create the beginning optimal population by using Linear Population Reduction Success History-based Adaptive Differential Evolution (LSHADE) and a novel Hyper-FDB-INFO algorithm was presented. Finally, the developed Hyper-FDB-INFO algorithm was applied to solve the optimal placement and sizing of FACTS devices for the optimal power flow (OPF) problem incorporating wind energy sources. Moreover, determining the placement and sizing of FACTS devices is an additional problem to minimize the total cost of generation and reducing the power losses of the power system. The experimental results showed that the Hyper-FDB-INFO algorithm is a more effective solver than the SHADE-SF, INFO, FDB-INFO and Hyper-INFO algorithms for wind power and FACTS devices integrating the OPF problem.
31 July 2019 in Düzce Üniversitesi Bilim ve Teknoloji Dergisi
Harmoniklere sebep olan eviriciler endüstride rüzgâr türbinlerinden, kesintisiz güç kaynaklarına kadar birçok alanda kullanılmaktadır. Harmonikler, sinüsoidal 3 fazlı AC formun bozulmasına sebep olmasının yanı sıra gerilim düşümleri, kesicilerin hatalı çalışması, motorlarda verimin düşmesi/sarsıntılı çalışma, trafolarda izolasyon sorunları gibi sorunlara sebep olmaktadır. Bu problemleri çözmek adına eviriciler üzerinden güç transferini en üst düzeye çıkarmak ve kaliteli enerji aktarımı için aktif veya pasif çeşitli filtreler kullanılmaktadır. Bu sebeple eviricilerin çıkışında L, LC, LCL, LLCL gibi pasif filtrelerin kullanılması kaçınılmaz olmaktadır. Bu çalışmada 3 fazlı eviriciler için LCL filtre tasarımı gerçekleştirilmiştir. Böylece IEEE 519’da belirlenen harmonik sınırlamalarının altında 3 fazlı akım ve gerilim üretilerek eviricinin kendisinin sebep olduğu harmonikler azaltılacaktır.