Additive manufacturing (AM) technologies are potential future-shaping solutions throughout many special applications in medicine. The mechanical behaviour of the related materials has not yet been fully explored. Here we compared five different industrial quality 3D printing materials produced using various AM processes that can be potentially used in limb-prosthetic development. We focused on the anisotropy of the mechanical and structural properties of these materials by using static and dynamic testing methods and electron microscopy imaging. Both static and dynamic experiments confirmed that amongst the three investigated directions (X, Y and Z), the Z orientation demonstrated, with the exception of polyamide test specimens, the lowest resistance against mechanical forces. Electron microscopy images revealed that greater mechanical stability appeared presumably due to the lengthier cooling time of the individual printed lines. Varying the printing resolution we showed how greater mechanical stability could be achieved, and concluded that special care should be taken when designing the AM processes intended for the fabrication of objects in support of medical applications. Often, the use of poor resolution in respect to quality of printing is desirable and can provide better solutions for actual purposes. These results provide important guidelines in the planning, manufacturing and implementation of higher developed, well-constructed assistive devices.
In this study, metal 3D printing technology was used to create lattice-shaped test specimens of orthopedic implants to determine the effect of different lattice shapes on bone ingrowth. Six different lattice shapes were used: gyroid, cube, cylinder, tetrahedron, double pyramid, and Voronoi. The lattice-structured implants were produced from Ti6Al4V alloy using direct metal laser sintering 3D printing technology with an EOS M290 printer. The implants were implanted into the femoral condyles of sheep, and the animals were euthanized 8 and 12 weeks after surgery. To determine the degree of bone ingrowth for different lattice-shaped implants, mechanical, histological, and image processing tests on ground samples and optical microscopic images were performed. In the mechanical test, the force required to compress the different lattice-shaped implants and the force required for a solid implant were compared, and significant differences were found in several instances. Statistically evaluating the results of our image processing algorithm, it was found that the digitally segmented areas clearly consisted of ingrown bone tissue; this finding is also supported by the results of classical histological processing. Our main goal was realized, so the bone ingrowth efficiencies of the six lattice shapes were ranked. It was found that the gyroid, double pyramid, and cube-shaped lattice implants had the highest degree of bone tissue growth per unit time. This ranking of the three lattice shapes remained the same at both 8 and 12 weeks after euthanasia. In accordance with the study, as a side project, a new image processing algorithm was developed that proved suitable for determining the degree of bone ingrowth in lattice implants from optical microscopic images. Along with the cube lattice shape, whose high bone ingrowth values have been previously reported in many studies, it was found that the gyroid and double pyramid lattice shapes produced similarly good results.
All types of cranioplasty techniques restore the morphology of the skull and affect patient aesthetics. Safe and easy techniques are required to enhance patients’ recovery and the rehabilitation process. We propose a new method of cranioplasty. The 3-dimensional (3D) reconstruction of a thin-layer computed tomography (CT) scan of the skull was used to reflect the intact side onto the defect and subtract the overlapping points from one another. In this way, a 3D model of the planned implant can be built in the required shape and size. The precise fit of the implant can be checked by printing the defective part of the skull in case it can be modified. A sterilisable silicone mould based on the finalized model was created afterwards. Polymethyl methacrylate implants were prepared directly in an aseptic environment in the operating room during surgery. Between 2005 and 2020, we performed 54 cranioplasties on 52 patients whose craniotomies were performed previously for indications of traumatic brain injury, stroke or tumour surgeries. No technical problems were noted during the operations. In 2 cases, septic complications that occurred were not connected to the technique itself, and the implants were removed and later replaced. Our proposed technique based on 3D-printed individual silicone moulds is a reliable, safe, easily reproducible and low-cost method to repair different skull defects.
Study Design. Different geometrical and biomechanical evaluations were performed to determine the axial rotational axis of the thoracic spine. Objective. Our research group has been dealing with the determination of the axial rotational axis of the thoracic spine. Here, we would like to present the geometrical and experimental results of our trials. With our experiments, we are trying to evaluate the contradictions of the related literature. Summary of Background Data. In the present state, we know quite a lot about the biomechanics of healthy and pathologic spines. Nevertheless, for a seemingly simple question like the position of the axial rotation of the thoracic spine, the literature gives contradicting results. During correction of a scoliotic deformity, when trying to correct the pathologic rotation, not knowing the physiologic rotation can be hazardous. Methods. We wanted to clarify this question, so we examined the thoracic spine in many different ways. First, we examined the problem from a geometrical point of view then we modeled the different rotational axes by studying the change in volume of the spinal canal. Finally, we used cadaver spines that we rotated and examined with radiographs and digital pictures. Results. Based on the results, we made the following establishments: most of the center points fell on the anterior half of the vertebral body or into the spinal canal, basically on the midsagittal axis of the vertebra. The rib cage has a significant effect on the place of the axis. After removing the ribs, the axis of axial rotation moved forward. Conclusions. After evaluating the results, we determined that the most likely place for the rotational axis is on the median-sagittal plane, in the anterior portion of the spinal canal.
18 February 2010 in Archives of orthopaedic and trauma surgery