In this paper, we have investigated the differences in the voices of Parkinson’s disease (PD) and age-matched control (CO) subjects when uttering three phonemes using two complexity measures: fractal dimension (FD) and normalised mutual information (NMI). Three sustained phonetic voice recordings, /a/, /u/ and /m/, from 22 CO (mean age = 66.91) and 24 PD (mean age = 71.83) participants were analysed. FD was first computed for PD and CO voice recordings, followed by the computation of NMI between the test groups: PD–CO, PD–PD and CO–CO. Four features reported in the literature—normalised pitch period entropy (Norm. PPE), glottal-to-noise excitation ratio (GNE), detrended fluctuation analysis (DFA) and glottal closing quotient (ClQ)—were also computed for comparison with the proposed complexity measures. The statistical significance of the features was tested using a one-way ANOVA test. Support vector machine (SVM) with a linear kernel was used to classify the test groups, using a leave-one-out validation method. The results showed that PD voice recordings had lower FD compared to CO (p < 0.008). It was also observed that the average NMI between CO voice recordings was significantly lower compared with the CO–PD and PD–PD groups (p < 0.036) for the three phonetic sounds. The average NMI and FD demonstrated higher accuracy (>80%) in differentiating the test groups compared with other speech feature-based classifications. This study has demonstrated that the voices of PD patients has reduced FD, and NMI between voice recordings of PD–CO and PD–PD is higher compared with CO–CO. This suggests that the use of NMI obtained from the sample voice, when paired with known groups of CO and PD, can be used to identify PD voices. These findings could have applications for population screening.
This study has developed a technique for identifying the presence of muscle fatigue based on the spatial changes of the normalised mutual information (NMI) between multiple high density surface electromyography (HD-sEMG) channels. Muscle fatigue in the tibialis anterior (TA) during isometric contractions at 40% and 80% maximum voluntary contraction levels was investigated in ten healthy participants (Age range: 21 to 35 years; Mean age = 26 years; Male = 4, Female = 6). HD-sEMG was used to record 64 channels of sEMG using a 16 by 4 electrode array placed over the TA. The NMI of each electrode with every other electrode was calculated to form an NMI distribution for each electrode. The total NMI for each electrode (the summation of the electrode’s NMI distribution) highlighted regions of high dependence in the electrode array and was observed to increase as the muscle fatigued. To summarise this increase, a function, M(k), was defined and was found to be significantly affected by fatigue and not by contraction force. The technique discussed in this study has overcome issues regarding electrode placement and was used to investigate how the dependences between sEMG signals within the same muscle change spatially during fatigue.
In this study we have tested the hypothesis regarding the increase in synchronization with the onset of muscle fatigue. For this aim, we have investigated the difference in the synchronicity between high density surface electromyogram (sEMG) channels of the rested muscles and when at the limit of endurance. Synchronization was measured by computing and normalizing the mutual information between the sEMG signals recorded from the high-density array electrode locations. Ten volunteers (Age range: 21 and 35 years; Mean age = 26 years; Male = 6, Female = 4) participated in our experiment. The participants performed isometric dorsiflexion of their dominate foot at two levels of contraction; 40% and 80% of their maximum voluntary contraction (MVC) until task failure. During the experiment an array of 64 electrodes (16 by 4) placed over the TA parallel to the muscle fiber was used to record the HD-sEMG. Normalized Mutual Information (NMI) between electrodes was calculated using the HD-sEMG data and then analyzed. The results show that that the average NMI of the TA significantly increased during fatigue at both levels of contraction. There was a statistically significant difference between NMI of the rested muscle compared with it being at the point of task failure.
In this study we propose an approach for increasing mobility scooter safety by detecting and avoiding obstacles. The detection system is based on obstacle detection and implemented using infrared and ultrasonic devices. The system is fully embedded and is composed of six infrared and three ultrasonic devices which allow: far detection for crossing objects or normal speed obstacle detection; close detection for low speed obstacles; side obstacle detection when turning. Three experiments have been carried out using our system in an indoor environment using different object shapes and sizes, crossing distances and turning angles. The system was able to detect all obstacles in the mobility scooters path with the exception of transparent flat surfaces. Obstacles passing in front were also successfully detected and when turning into walls the system correctly detected them.
In this study we developed a technique for identifying noisy electrodes in high density surface electromyography (HD-sEMG). The technique finds the spatial similarity of each electrode in the electrode array by counting the number of interactions the electrode has. Using this information the technique identifies noisy electrodes by finding electrodes that are significantly dissimilar to the other electrodes. The HD-sEMG recordings used in this study were taken from three participants who performed two isometric contractions of their biceps at 40% and 80% of their maximum voluntary contraction (MVC) force. White Gaussian noisy was added to a varying number of recorded signals before being digital filtering to generate a variety of recordings to test the technique with. In the recordings, groups of 2, 4, 8, and 16 electrodes had noise added such that the signal to noise ratios (SNR) were 0, 5, 10, 15, and 20dB. The results show that the technique can reliably identify groups of 2, 4, and 8 noisy electrodes with SNRs of 0, 5, and 10dB.
This study has investigated the use of inter-personnel mutual information computed from the phonetic sound recordings to differentiate between Parkinson’s disease (PD) and control subjects. The normalized mutual information (NMI) denotes the amount of information shared between the voice recordings of people within the same group: PD and Control. The hypothesis of this study was that within group NMI will be significantly different when compared with inter- group NMI. For each phonetic sound, the NMI was computed for every pairing of recordings for both the PD and control groups. Pearson correlation coefficient analysis was used to determine the association of NMI with clinical parameters including Unified Parkinson’s Disease Rating Scale (UPDRS), Montreal cognitive assessment (MoCA) and disease duration. ANOVA test for the three phonetic sounds of control and PD subjects showed that there is significant difference between the intra-group mean NMI for the two groups (p < 0.003) and also showed significant association with the UPDRS motor examination score, MoCA and disease duration.