The effect of accidental drops on MEMS sensors are examined within the frame-work of a multi-scale finite element approach. With specific reference to a polysilicon MEMSaccelerometer supported by a naked die, the analysis is decoupled into macro-scale (at dielength-scale) and meso-scale (at MEMS length-scale) simulations, accounting for the verysmall inertial contribution of the sensor to the overall dynamics of the device. Macro-scaleanalyses are adopted to get insights into the link between shock waves caused by the impactagainst a target surface and propagating inside the die, and the displacement/acceleration his-tories at the MEMS anchor points. Meso-scale analyses are adopted to detect the most stresseddetails of the sensor and to assess whether the impact can lead to possible localized failures.Numerical results show that the acceleration at sensor anchors cannot be considered an ob-jective indicator for drop severity. Instead, accurate analyses at sensor level are necessary toestablish how MEMS can fail because of drops.
Failure of packaged polysilicon micro-electro-mechanical systems (MEMS) subjected to impacts involves phenomena occurring at several length-scales. In this paper we present a multi-scale finite element approach to properly allow for: (i) the propagation of stress waves inside the package; (ii) the dynamics of the whole MEMS; (iii) the spreading of micro-cracking in the failing part(s) of the sensor. Through Monte Carlo simulations, some effects of polysilicon micro-structure on the failure mode are elucidated.