The specific design of the mobile dedicated intraoperative radiotherapy (IORT) accelerators and different electron beam collimation system can change the dosimetric characteristics of electron beam with respect to the conventional accelerators. The aim of this study is to measure and compare the dosimetric characteristics of electron beam produced by intraoperative and conventional radiotherapy accelerators. To this end, percentage depth dose along clinical axis (PDD), transverse dose profile (TDP), and output factor of LIAC IORT and Varian 2100C/D conventional radiotherapy accelerators were measured and compared. TDPs were recorded at depth of maximum dose. The results of this work showed that depths of maximum dose, , and for LIAC beam are lower than those of Varian beam. Furthermore, for all energies, surface doses related to the LIAC beam are substantially higher than those of Varian beam. The symmetry and flatness of LIAC beam profiles are more desirable compared to the Varian ones. Contrary to Varian accelerator, output factor of LIAC beam substantially increases with a decrease in the size of the applicator. Dosimetric characteristics of beveled IORT applicators along clinical axis were different from those of the flat ones. From these results, it can be concluded that dosimetric characteristics of intraoperative electron beam are substantially different from those of conventional clinical electron beam. The dosimetric characteristics of the LIAC electron beam make it a useful tool for intraoperative radiotherapy purposes. PACS number: 87.56.-v, 87.56.bd
Lymphoma, encompassing a wide spectrum of immune system malignancies, presents significant complexities in its early detection, management, and prognosis assessment since it can mimic post-infectious/inflammatory diseases. The heterogeneous nature of lymphoma makes it challenging to definitively pinpoint valuable biomarkers for predicting tumor biology and selecting the most effective treatment strategies. Although molecular imaging modalities, such as positron emission tomography/computed tomography (PET/CT), specifically 18F-FDG PET/CT, hold significant importance in the diagnosis of lymphoma, prognostication, and assessment of treatment response, they still face significant challenges. Over the past few years, radiomics and artificial intelligence (AI) have surfaced as valuable tools for detecting subtle features within medical images that may not be easily discerned by visual assessment. The rapid expansion of AI and its application in medicine/radiomics is opening up new opportunities in the nuclear medicine field. Radiomics and AI capabilities seem to hold promise across various clinical scenarios related to lymphoma. Nevertheless, the need for more extensive prospective trials is evident to substantiate their reliability and standardize their applications. This review aims to provide a comprehensive perspective on the current literature regarding the application of AI and radiomics applied/extracted on/from 18F-FDG PET/CT in the management of lymphoma patients.
The aim of this study was to investigate the antitumor effectiveness of electrochemotherapy with cisplatin combined with suboptimal radiotherapy doses. Tumor radiosensitization was evaluated on large invasive ductal carcinoma tumors in Balb/C mice. Tumors of an average volume of 630 mm3 were treated with cisplatin, electric pulses, radiotherapy, electrochemotherapy, alone as well as in appropriate combinations. Tumors were irradiated with Cobalt-60 γ-rays at doses 3 Gy and 5 Gy in combination with electrochemotherapy using cisplatin. Controls included each of the treatments alone as well as the combination of the radiotherapy with electric pulses alone or with cisplatin alone. Antitumor effectiveness was evaluated by tumor growth delay, tumor-doubling time, inhibition ratio and the objective response rates. As anticipated, electrochemotherapy was more effective than the treatment with cisplatin alone or the application of the electric pulses alone. When treatments were combined with tumor irradiation at either 3 or 5 Gy, the combination with electrochemotherapy was more effective: at 5 Gy, 2 animals out of 8 were in complete remission 100 days later. In general the higher 5 Gy dose of γ-radiation was more effective than the lower one of 3 Gy. The results of our study demonstrate that irradiation doses, 3 Gy or 5 Gy, increase the antitumor effectiveness of electrochemotherapy with cisplatin on invasive ductal carcinoma tumors. Good antitumor results were achieved in experimental tumors with a size comparable to clinical lesions, demonstrating that this three-modality combined treatment is useful for the treatment of large lesions even at sub-optimal radiotherapy doses.
1 June 2019 in International Journal of Nanomedicine
Background: During decades, all improvements and developments in radiation therapy technologies have been focused on its main goal: maximize the dose in the tumor and minimize it in surrounding normal tissues. Recently, scientists have some approaches to nanoparticles, especially gold nanoparticles (GNPs), for dose localization. Purpose: Herein, the effect of GNPs in combination with electron brachytherapy in a model of eye tumor has been investigated. Materials and methods: Monte Carlo simulation was utilized and a complete anatomical model of the eye, a tumor with 5 mm thick, and a type of Ruthenium-106 beta emitter ophthalmic plaque were simulated. Simulation results have been validated by a Plexiglas eye phantom and film dosimetry, experimentally. Results: The results showed using GNPs causes the dose amplification in 2 mm from the plaque surface which the higher concentration has the higher enhancement. At more distances, Dose Enhancement Factors (DEFs) have the negative amounts, so that total delivered dose to the tumor has decreased with increasing of Au concentrations and the dose of organ at risk like sclera has increased. Conclusion: Therefore, using of GNPs along with a 106,Ru/106,Rh ocular plaque, as an electron emitter source, is a good choice only for superficial lesions, and it is not recommended for deeper tumors due to the parameters of radiation treatment and delivered dose to the tissues.
8 August 2019 in Applied Biochemistry and Biotechnology