Hengfa Lu

Mr. Hengfa Lu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
XZXinlin Zhang
Xinlin Zhang
HLHengfa Lu
Hengfa Lu
DGDi Guo
Di Guo
ZLZongying Lai
Zongying Lai
HYHuihui Ye
Huihui Ye
XQXiaobo Qu
Xiaobo Qu
Magnetic resonance imaging serves as an essential tool for clinical diagnosis, however, suffers from a long acquisition time. Sparse sampling effectively saves this time but images need to be faithfully reconstructed from undersampled data. Among the existing reconstruction methods, the structured low-rank methods have advantages in robustness to the sampling patterns and lower error. However, the structured low-rank methods use the 2D or higher dimension k-space data to build a huge block Hankel matrix, leading to considerable time and memory consumption. To reduce the size of the Hankel matrix, we proposed to separably construct multiple small Hankel matrices from rows and columns of the k-space and then constrain the low-rankness on these small matrices. This separable model can significantly reduce the computational time but ignores the correlation existed in inter- and intra-row or column, resulting in increased reconstruction error. To improve the reconstructed image without obviously increasing the computation, we further introduced the self-consistency of k-space and virtual coil prior. Besides, the proposed separable model can be extended into other imaging scenarios which hold exponential characteristics in the parameter dimension. The in vivo experimental results demonstrated that the proposed method permits the lowest reconstruction error with a fast reconstruction. The proposed approach requires only 4% of the state-of-the-art STDLR-SPIRiT runtime for parallel imaging reconstruction, and achieves the fastest computational speed in parameter imaging reconstruction.

7 March 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
ECEvan Scope Crafts
Evan Scope Crafts
HLHengfa Lu
Hengfa Lu
HYHuihui Ye
Huihui Ye
LWLawrence L. Wald
Lawrence L. Wald
BZBo Zhao
Bo Zhao

8 September 2022 in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Verified
Conference Paper
Closed access
HLHengfa Lu
Hengfa Lu
HYHuihui Ye
Huihui Ye
BZBo Zhao
Bo Zhao
Magnetic Resonance (MR) Fingerprinting is an emerging transient-state imaging paradigm, which enables the quantization of multiple MR tissue parameters in a single experiment. Balanced steady-state free precession (bSSFP)-based MR Fingerprinting has excellent signal-to-noise characteristics and also allows for acquiring both tissue parameter maps and field inhomogeneity maps. However, field inhomogeneity often results in complex magnetization evolutions in bSSFP-based MR Fingerprinting, which creates significant challenges in image reconstruction. In this paper, we introduce a new method to address the image reconstruction problem. The proposed method incorporates a low-dimensional nonlinear manifold learned from an ensemble of magnetization evolutions using a deep autoencoder. It provides much better representation power than a low-dimensional linear subspace in capturing complex magnetization evolutions. We formulate the image reconstruction problem with this nonlinear model and solve the resulting optimization problem using an algorithm based on variable splitting and the alternating direction method of multipliers. We evaluate the performance of the proposed method using numerical experiments and demonstrate that it significantly outperforms the state-of-art method using a linear subspace model.

5 February 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
HLHengfa Lu
Hengfa Lu
JAJewel Ashbrook
Jewel Ashbrook
ADAndrew K Dunn
Andrew K Dunn
Multi-exposure speckle imaging (MESI) estimates flow-related parameters by fitting a physics-based speckle contrast model to measurements acquired over multiple exposure times. In standard pipelines, parameters are recovered via nonlinear least-squares fitting at each pixel, which is computationally expensive and can yield spatially inconsistent maps when uncertainty in the estimated speckle contrast variance (from camera noise and finite spatial/temporal sampling used to compute speckle contrast) is amplified by independent pixel wise inversion. This work reframes MESI parameter estimation as identification of a globally shared inverse operator of the analytical forward model, exploiting the fact that a single physical mapping governs all pixels while noise drives large variance in independent pixel wise inversion. Rather than solving millions of iterative optimizations, a single parameterized inverse mapping is learned directly from a single acquired MESI dataset. Physics consistency is enforced by embedding the fixed MESI forward model as an analysis-by-synthesis layer that re-synthesizes speckle contrast curves from the predicted parameters. Training is self-supervised: the inverse mapping is optimized by minimizing a reconstruction loss between measured and re-synthesized speckle contrast curves, which constrains estimates to the set of physically admissible MESI curves without requiring ground truth parameter labels. Experiments on a numerical MESI phantom with known ground truth and on in vivo mouse cortex data show that the proposed method produces more stable inverse correlation time (ICT) maps (1 /τ c ) and improved spatial coherence relative to conventional per-pixel fitting, while substantially reducing inference time by replacing iterative optimization with a single feed-forward evaluation.

25 May 2023 in arXiv
Verified
Preprint
Open access
PDF file
HLHengfa Lu
Hengfa Lu
HYHuihui Ye
Huihui Ye
LWLawrence L. Wald
Lawrence L. Wald
BZBo Zhao
Bo Zhao
Magnetic Resonance (MR) Fingerprinting is an emerging multi-parametric quantitative MR imaging technique, for which image reconstruction methods utilizing low-rank and subspace constraints have achieved state-of-the-art performance. However, this class of methods often suffers from an ill-conditioned model-fitting issue, which degrades the performance as the data acquisition lengths become short and/or the signal-to-noise ratio becomes low. To address this problem, we present a new image reconstruction method for MR Fingerprinting, integrating low-rank and subspace modeling with a deep generative prior. Specifically, the proposed method captures the strong spatiotemporal correlation of contrast-weighted time-series images in MR Fingerprinting via a low-rank factorization. Further, it utilizes an untrained convolutional generative neural network to represent the spatial subspace of the low-rank model, while estimating the temporal subspace of the model from simulated magnetization evolutions generated based on spin physics. Here the architecture of the generative neural network serves as an effective regularizer for the ill-conditioned inverse problem without additional spatial training data that are often expensive to acquire. The proposed formulation results in a non-convex optimization problem, for which we develop an algorithm based on variable splitting and alternating direction method of multipliers.We evaluate the performance of the proposed method with numerical simulations and in vivo experiments and demonstrate that the proposed method outperforms the state-of-the-art low-rank and subspace reconstruction.

23 April 2026 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
HLHengfa Lu
Hengfa Lu
QFQingwei Fang
Qingwei Fang
JAJewel A. Ashbrook
Jewel A. Ashbrook
VNVictoria Nemchek
Victoria Nemchek
MFMichela Fracassi
Michela Fracassi
ADAndrew K Dunn
Andrew K Dunn
Measuring fast dynamic processes with dynamic light scattering over wide fields of view is critical for applications ranging from blood flow imaging to characterizing complex fluids, yet is often limited by the need for expensive, high frame rate cameras. Here, we introduce sinusoidal intensity modulation speckle imaging (SIMSI), a technique that overcomes this hardware limitation by encoding information about fast dynamics into images captured with long camera exposures. Within each exposure, we sinusoidally modulate the illumination intensity, yielding frequency selective speckle variance measurements that sample the power spectral density (PSD) of intensity fluctuations. By sweeping the modulation frequency across exposures, SIMSI maps the PSD while preserving high signal-to-noise long exposures. We fit the measured spectra with a flexible model and report a spectral cutoff frequency f c as a flow index. In controlled flow microfluidic phantoms, SIMSI PSD estimates agree with the reference PSD measurements from a coaligned high-speed detector, and the derived f c varies linearly with the imposed flow velocity ( R 2 > 0.999 ). In vivo in the mouse cortex, the SIMSI derived f c maps distinguish vascular compartments with distinct spectral signatures. Finally, SIMSI tracks the spatiotemporal evolution of cortical blood flow changes for ten days following ischemic stroke. SIMSI provides a robust and accessible method for wide field, frequency domain characterization of fast dynamics using standard cameras. This advance enables a richer characterization of complex systems and has wide ranging applications in biomedicine, engineering, and physics.