Tran Thanh Tam Toan

Dr. Tran Thanh Tam Toan


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in Journal of Environmental Chemical Engineering
Verified
Journal Article
Closed access
HTHuynh Thi Minh Thanh
Huynh Thi Minh Thanh
TPTran Thi Thu Phuong
Tran Thi Thu Phuong
PHPhan Thi Le Hang
Phan Thi Le Hang
TTTran Thanh Tam Toan
Tran Thanh Tam Toan
TTTran Ngoc Tuyen
Tran Ngoc Tuyen
DKDinh Quang Khieu
Dinh Quang Khieu

1 October 2018 in Journal of Environmental Chemical Engineering
Verified
Journal Article
Closed access
LTLe Thi Thanh Tuyen
Le Thi Thanh Tuyen
DQDao Anh Quang
Dao Anh Quang
TTTran Thanh Tam Toan
Tran Thanh Tam Toan
TTTruong Quy Tung
Truong Quy Tung
THTran Thai Hoa
Tran Thai Hoa
DKDinh Quang Khieu
Dinh Quang Khieu

17 April 2019 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
NTNguyen Mau Thanh
Nguyen Mau Thanh
NHNguyen Van Hop
Nguyen Van Hop
NLNguyen Dinh Luyen
Nguyen Dinh Luyen
NPNguyen Hai Phong
Nguyen Hai Phong
TTTran Thanh Tam Toan
Tran Thanh Tam Toan
The simultaneous electrochemical determination of Zn(II), Cd(II), Pb(II), and Cu(II) in the aqueous solution has been developed on the basis of the bismuth film glassy carbon electrode (GCE) using differential pulse anodic stripping voltammetry (DP-ASV). The bismuth film electrode (BiFE) was prepared by adding 500 ppb bismuth(III) directly to the sample solution and simultaneously depositing bismuth and the metal analytes on GCE. The optimal operational parameters, namely, accumulation potential (–1.6 V), accumulation time (110 s), pulsed amplitude (0.07 V), and scan rate (0.021 V·s−1), were found using a Box–Behnken design. Under the optimum conditions, a linear relationship exists between the current and the concentration of Zn(II), Cd(II), Pb(II), and Cu(II) in the range between 5.0 ppb and 110.0 ppb with the detection limits of 1.07 for Zn(II), 0.93 ppb for Cd(II), 0.65 ppb for Pb(II), and 0.94 ppb for Cu(II) calculated on the basis of a signal-to-noise ratio equal to 3 (S/N = 3). The interference experiments show that Co(II), Ni(II), and Fe(III) have a little influence on the DP-ASV signals of Zn(II), Cd(II), Pb(II), and Cu(II). In addition, a high reproducibility was indicated from small relative standard deviations (1.03%, 1.74%, 1.32%, and 4.74%) for 25 repeated measurements of 15 ppb copper, lead, cadmium, and zinc solutions. BiFE was successfully applied to determine Zn(II), Cd(II), Pb(II), and Cu(II) in river samples, and the results are in a good agreement with those determined with graphite furnace atomic absorption spectrometry (GF-AAS).

29 August 2022 in ECS Sensors Plus
Verified
Journal Article
Open access
DNDo Mai Nguyen
Do Mai Nguyen
TTTran Thanh Tam Toan
Tran Thanh Tam Toan
In this study, a PoL/RGO material was successfully synthesized and employed to modify the working electrode for determining MPB in medication products through voltammetric techniques. The structure of the nanocomposite was characterized by UV–vis and FT-IR spectrum and its application to the MPB electrochemical detection was tested by the CV and DPV techniques. In the result, the modified PoL-RGO/GCE electrode exhibited a superior response toward MPB by applying the DPV method, compares to using the bare GCE, with a limit of detection (LOD), a limit of quantification (LOQ) is 0.20 μM and 0.70 μM, respectively and the concentration ranging from 1 to 200 μM. In addition, the repeatability (RSD of 2.2, 1.6, 1.4 for 5, 50 and 100 μM MPB, respectively), and the reproducibility (RSD of 4.7%) of the technique were examined as well. This illustrates the performance of the electrochemical sensor was statistically investigated by the CV and DPV methods demonstrating accuracy comparable to other analytical methods as well as indicating that MPB can be determined in cosmetics with high recovery ranging from 97% to 104.3%.

28 May 2019 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
NTNguyen Thi Thanh Tu
Nguyen Thi Thanh Tu
PSPhung Chi Sy
Phung Chi Sy
TTTran Vinh Thien
Tran Vinh Thien
TTTran Thanh Tam Toan
Tran Thanh Tam Toan
NPNguyen Hai Phong
Nguyen Hai Phong
DKDinh Quang Khieu
Dinh Quang Khieu

1 June 2022 in ECS Sensors Plus
Verified
Journal Article
Open access
TTTran Thanh Tam Toan
Tran Thanh Tam Toan
DNDo Mai Nguyen
Do Mai Nguyen
The features of NMTs such as graphene, molybdenum disulfide, CNTs and quantum dots for unique sensing applicability are mentioned in this review study. Some notable sensors that have been produced are described based on the particular analyte compound to be determined and the functionalization processes that are used. For COVID-19 determination, biocompatible sensors manufactured from these materials capable of determining specific chemical components are also highlighted, which could support efficient and reliable sensing and rapid diagnosis.