With demand for the long-term continued use of existing building facilities, structural health monitoring and damage detection are attracting interest from society. Sensors of various types have been practically applied in the industry to satisfy this need. Among the sensors, piezoelectric sensors are an extremely promising technology by virtue of their cost advantages and durability. Although they have been used in aerospace and civil engineering, their application for building engineering remains limited. Remarkably, recent catastrophic seismic events have further reinforced the necessity of rapid damage detection and quick judgment about the safe use of facilities. Faced with these circumstances, this study was conducted to assess the applicability of piezoelectric sensors to detect damage to building components stemming from concrete cracks and local buckling. Specifically, this study emphasizes structural damage caused by earthquakes. After first applying them to cyclic loading tests to composite beam component specimens and steel frame subassemblies with a folded roof plate, the prospective damage positions were also found using finite element analysis. Crack propagation and buckling locations were predicted adequately. The piezoelectric sensors provided output when the concrete slab showed tensile cracks or when the folded roof plate experienced local buckling. Furthermore, damage expansion and progression were detected multiple times during loading tests. Results showed that the piezoelectric sensors can detect the structural damage of building components, demonstrating their potential for use in inexpensive and stable monitoring systems.

23 August 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
ASAtsushi Suzuki
Atsushi Suzuki
WLWang Liao
Wang Liao
DSDaiki Shibata
Daiki Shibata
YYYuki Yoshino
Yuki Yoshino
YKYoshihiro Kimura
Yoshihiro Kimura
NSNobuhiro Shimoi
Nobuhiro Shimoi
With demand for the long-term continued use of existing building facilities, structural health monitoring and damage detection are attracting interest from society. Sensors of various types have been practically applied in the industry to satisfy this need. Among the sensors, piezoelectric sensors are an extremely promising technology by virtue of their cost advantages and durability. Although they have been used in aerospace and civil engineering, their application for building engineering remains limited. Remarkably, recent catastrophic seismic events have further rein-forced the necessity of rapid damage detection and quick judgment about the safe use of facilities. Faced with these circumstances, this study was conducted to assess the applicability of piezoelectric sensors to evaluate building components. Specifically, this study emphasizes structural damage caused by earthquakes. After first applying to cyclic loading tests to composite beam component specimens and steel frame subassemblies with a folded roof plate, the prospective damage posi-tions were also found using finite element analysis. Crack propagation and buckling locations were predicted adequately. The piezoelectric sensors provided output when the concrete slab showed tensile cracks, or when the folded roof plate experienced local buckling. Furthermore, damage expansion and progression were detected multiple times during loading tests. Results showed that the piezoelectric sensors can detect structural damage of building components, demonstrating their potential for use in inexpensive and stable monitoring systems.

19 April 2024 in Buildings
Verified
Journal Article
Open access
PDF file
YYYuki Yoshino
Yuki Yoshino
YKYoshihiro Kimura
Yoshihiro Kimura
Non-structural members, such as roofs and ceilings, become affixed to main beams that are known as structural members. When such main beams experience bending or compressive forces that lead to lateral buckling, non-structural members may act to restrain the resulting lateral buckling deformation. Nevertheless, neither Japanese nor European guidelines advocate for the utilization of non-structural members as lateral buckling stiffeners for beams. Additionally, local buckling ensues near the bolt apertures in the beam–roof folded plate connection due to the torsional deformation induced by the lateral buckling of the H beam, thereby reducing the rotational stiffness of the roof folded plate to a percentage of its ideal stiffness. This paper conducts torsional experiments on roof folded plates, and with various connection methods between these plates and the beams, to comprehend the deformation mechanism of roof folded plates and the relationship between their rotational stiffness and the torsional moment. Then, the relationship between the demand values against restraining the lateral buckling of the main beam and the experimentally determined bearing capacity of the roof folded plate is elucidated. Results indicate the efficacy of utilizing the roof folded plate as a continuous brace. The lateral buckling design capacity of H beams that are continuously stiffened by roof folded plates is elucidated via application of a connection method that ensures joint stiffness between the roof folded plate and the beam while using Japanese and European design codes.

2 February 2025 in Buildings
Verified
Journal Article
Open access
PDF file
YYYuki Yoshino
Yuki Yoshino
YKYoshihiro Kimura
Yoshihiro Kimura
When a beam twists, localized flexural deformation in the plate occurs at the connection between the corrugated plate and the beam, resulting in a reduction in the bracing stiffness of the corrugated plate. To accurately assess the bracing stiffness of a beam with a connected corrugated plate, it is essential to independently determine the bending stiffness of the corrugated plate and the rotational stiffness of the plate–beam joint. This study conducts bending experiments on corrugated plates subjected to in-plane bending to elucidate the stress mechanisms within the plates. The influence of the width-to-thickness ratio on the bending load and bending stiffness of the corrugated plates is examined using the width-to-thickness ratio regulations of various countries. The findings revealed that when the width-to-thickness ratio of the corrugated plates used in this study was lower than the threshold specified in the Eurocode, the bending load at the onset of stiffness degradation was approximately 80% of the maximum bending load, and the initial bending stiffness corresponded closely to the theoretical value. Conversely, when the web width-to-thickness ratio of the corrugated plates exceeded the limit prescribed in the Eurocode, it was demonstrated that the maximum bending load decreased to approximately 50% of the yield load, and the initial bending stiffness was reduced to about 95% of the theoretical value.