11 January 2024 in Oncology and Therapy
Verified
Journal Article
Open access
PDF file
FPFrancesco Pepe
Francesco Pepe
Gianluca RussoGianluca Russo
Gianluca Russo
AVAlessandro Venuta
Alessandro Venuta
CSClaudia Scimone
Claudia Scimone
MNMariantonia Nacchio
Mariantonia Nacchio
Giancarlo TronconeGiancarlo Troncone
Giancarlo Troncone
Introduction Biomarker testing is mandatory for the clinical management of patients with advanced non-small cell lung cancer (NSCLC). Myriads of technical platforms are now available for biomarker analysis with differences in terms of multiplexing capability, analytical sensitivity, and turnaround time (TAT). We evaluated the technical performance of the diagnostic workflows of 24 representative Italian institutions performing molecular tests on a series of artificial reference specimens built to mimic routine diagnostic samples. Methods Sample sets of eight slides from cell blocks of artificial reference specimens harboring exon 19 EGFR (epidermal growth factor receptor) p.E746_AT50del, exon 2 KRAS (Kirsten rat sarcoma viral oncogene homologue) p.G12C, ROS1 (c-ros oncogene 1)-unknown gene fusion, and MET (MET proto-oncogene, receptor tyrosine kinase) Δ exon 14 skipping were distributed to each participating institution. Two independent cell block specimens were validated by the University of Naples Federico II before shipment. Methodological and molecular data from reference specimens were annotated. Results Overall, a median DNA concentration of 3.3 ng/µL (range 0.1–10.0 ng/µL) and 13.4 ng/µL (range 2.0–45.8 ng/µL) were obtained with automated and manual technical procedures, respectively. RNA concentrations of 5.7 ng/µL (range 0.2–11.9 ng/µL) and 9.3 ng/µL (range 0.5–18.0 ng/µL) were also detected. KRAS exon 2 p.G12C, EGFR exon 19 p.E736_A750del hotspot mutations, and ROS1 aberrant transcripts were identified in all tested cases, whereas 15 out of 16 (93.7%) centers detected MET exon 14 skipping mutation. Conclusions Optimized technical workflows are crucial in the decision-making strategy of patients with NSCLC. Artificial reference specimens enable optimization of diagnostic workflows for predictive molecular analysis in routine clinical practice.

28 July 2025 in The Journal of Liquid Biopsy
Verified
Journal Article
Open access
FPFrancesco Pepe
Francesco Pepe
Gianluca RussoGianluca Russo
Gianluca Russo
Konstantinos VenetisKonstantinos Venetis
Konstantinos Venetis
CSClaudia Scimone
Claudia Scimone
LPLucia Palumbo
Lucia Palumbo
UMUmberto Malapelle
Umberto Malapelle
To date, ESR1 activating mutations acts as key player to clinically stratify estrogen receptor (ER)+/HER2-advanced breast cancer (BC) patients eligible to novel new generation oral Selective Estrogen Receptor Degraders (SERD) relapsing after first line aromatase inhibitors. Liquid biopsy represents the most useful biological source to detect ESR1 activating mutations in clinical setting, but the lack of standardized pre-analytical and analytical procedures drastically impacts on detection rate of ESR1 mutations in diagnostic specimens. Here, we sought to harmonize technical procedures comparing technical performance of diagnostically available testing strategies on a series of three reference specimens (sample A, B, C) harboring ESR1 p.D538G mutation at different mutant allele fraction (MAF) (5.0 %, 1.0 %, 0.5 %) shared with n = 10 Italian referral institutions. A total of 10 μl of gDNA from each reference sample built to mimic clinically detectable ESR1 molecular alteration (5.0 %, 1.0 %, 0.5 % VAF) was shipped by coordinator institution to each participating group to test p.D538G ESR1 alteration leveraging own routinely available testing strategy. Artificial reference sample was previously validated by the University of Naples Federico II before arranging the shipment. ESR1 exon 10 p.(D538G) hotspot mutation was successfully identified in 90.0 % of samples A, B whereas 8 out of 10 (80.0 %) participating institutions detected sample referenced alteration in sample C. No statistically significant variations were observed between dPCR and NGS based workflows in terms of detectability rate on standard reference samples. A single participating institution (ID#5) failed to detect p.(D538G) ESR1 alteration but supervised procedures by coordinator institution enabled to detect referenced mutation in engineered reference samples set adopting an orthogonal technology (dPCR). In addition, NGS and dPCR platforms displayed a similar technical performance in detecting ESR1 across samples A-C. NGS and dPCR systems may be considered valid technical solutions to target low frequency ESR1 alterations in diagnostic routine samples. Harmonized ring trials are key weapons to standardize analytical and post-analytical procedures optimizing clinical stratification of BC patients

31 October 2023 in Journal of Molecular Pathology
Verified
Journal Article
Open access
PDF file
CLCaterina De Luca
Caterina De Luca
FPFrancesco Pepe
Francesco Pepe
Gianluca RussoGianluca Russo
Gianluca Russo
MNMariantonia Nacchio
Mariantonia Nacchio
Pasquale PisapiaPasquale Pisapia
Pasquale Pisapia
UMUmberto Malapelle
Umberto Malapelle
Aims: To date, precision medicine has played a pivotal role in the clinical administration of solid-tumor patients. In this scenario, a rapidly increasing number of predictive biomarkers have been approved in diagnostic practice or are currently being investigated in clinical trials. A pitfall in molecular testing is the diagnostic routine sample available to analyze predictive biomarkers; a scant tissue sample often represents the only diagnostical source of nucleic acids with which to conduct molecular analysis. At the sight of these critical issues, next-generation sequencing (NGS) platforms emerged as referral testing strategies for the molecular analysis of predictive biomarkers in routine practice, but the need for highly skilled personnel and extensive working time drastically impacts the widespread diffusion of this technology in diagnostic settings. Here, we technically validate a fully integrated NGS platform on diagnostic routine tissue samples previously tested with an NGS-based diagnostic workflow by a referral institution. Methods: A retrospective series of n = 64 samples (n = 32 DNA, n = 32 RNA samples), previously tested using a customized NGS assay (SiRe™ and SiRe fusion), was retrieved from the internal archive of the University of Naples Federico II. Each sample was tested by adopting an Oncomine Precision Assay (OPA), which is able to detect 2769 molecular actionable alterations [hotspot mutations, copy number variations (CNV) and gene fusions] on fully integrated NGS platforms (Genexus, Thermo Fisher Scientific (Waltham, MA, USA). The concordance rate between these technical approaches was determined. Results: The Genexus system successfully carried out molecular analysis in all instances. A concordance rate of 96.9% (31 out of 32) was observed between the OPA and SiRe™ panels both for DNA- and RNA-based analysis. A negative predictive value of 100% and a positive predictive value of 96.9% (62 out of 64) were assessed. Conclusions: A fully automatized Genexus system combined with OPA (Thermo Fisher Scientific) may be considered a technically valuable, time-saving sequencing platform to test predictive biomarkers in diagnostic routine practice.

13 December 2024 in Journal of Molecular Pathology
Verified
Journal Article
Open access
PDF file
MSMauro Scimia
Mauro Scimia
FPFrancesco Pepe
Francesco Pepe
Gianluca RussoGianluca Russo
Gianluca Russo
UMUmberto Malapelle
Umberto Malapelle
SSSimone Scimia
Simone Scimia
Giancarlo TronconeGiancarlo Troncone
Giancarlo Troncone
Introduction: Colorectal cancer screening programs are effective in reducing incidence and mortality. In Europe, every FIT+ patient is referred to colonoscopy. The available data show that ~75.0% of these patients are negative. It is desirable to select patients at a greater risk of having a positive colonoscopy. Materials and Methods: 711 subjects, aged 50–74, attending the screening program of ASL-NA-3-SUD (Naples, Italy), were enrolled in a cross-sectional study to evaluate the performance of the QuantiDNA™ test and the non-inferiority of an alternative approach (AAP). This evaluation is based on FIT+ and QuantiDNA™+ patients referred to colonoscopy, compared to Standard of Care (SOC) colonoscopy following a FIT+ test alone. A non-inferiority margin (NIM) for colorectal neoplasia (CN) and advanced adenomas (AA) was set at −10% and at −3.8% for CRC. Results: The odds ratio was 1.76 (p-value = 0.009). The detection rate of AAP was 15.9% for colorectal neoplasia, 13.0% for advanced adenoma, and 3.0% for CRC. The risk difference between AAP and SOC was −5.07% (95% C.I. −9.23, −0.90) for colorectal neoplasia, −4.02% (95% C.I. −7.89, −0.16) for advanced adenomas, and −1.04% (95% C.I. −3.16, 1.07) for CRC. This data suggests that AAP is non-inferior to SOC for detecting CN, AA, and CRC. The expected decrease in colonoscopies is 33.4%. Conclusions: The QuantiDNA™ test is straightforward, non-invasive, and well-tolerated. Data from this study indicate that it is effective in the reduction of the need for colonoscopy examinations (−33.4%) and is non-inferior to SOC in the detection of significant colorectal lesions.

28 September 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
CLCaterina De Luca
Caterina De Luca
FPFrancesco Pepe
Francesco Pepe
Gianluca RussoGianluca Russo
Gianluca Russo
MNMariantonia Nacchio
Mariantonia Nacchio
Pasquale PisapiaPasquale Pisapia
Pasquale Pisapia
UMUmberto Malapelle
Umberto Malapelle
Aims: To date, precision medicine plays a pivotal role in the clinical administration of solid tumor patients. In this scenario, a rapidly increasing number of predictive biomarkers have been approved in diagnostic practice or are currently investigated in clinical trials. A pitfall in the molecular tests is the diagnostic routine sample available to analyze predictive biomarkers; scant tissue sample often represents the only diagnostical source of nucleic acids to assess molecular analysis. At the sight of these critical issues, Next Generation Sequencing (NGS) platforms emerged as referral testing strategy for molecular analysis of predictive biomarkers in routine practice but high-skilled personnel, extensive working-time drastically impact on the widespread diffusion of this technology in diagnostic setting. Here, we technically validate a fully integrated NGS platform on diagnostic routine tissue samples previously tested with NGS based diagnostic workflow by a referral institution. Methods: A retrospective series of n=64 samples (n=32 DNA, n=32 RNA samples), previously tested using a customized NGS assay (SiRe™ and SiRe fusion) were retrieved from internal archive of University of Naples Federico II. Each sample was tested by adopting Oncomine Precision Assay (OPA), able to detect 2769 molecular actionable alterations [hot spot mutations, copy number variations (CNV) and gene fusions on fully integrated NGS platform (Genexus, Thermofisher Scientifics. (26,27) Concordance rate between these technical approaches was carried out. Results: Genexus system successfully carried out molecular analysis in all instances. A concordance rate of 96.9% (31 out of 32) was observed between OPA and SiRe™ panel both for DNA and RNA based analysis. A negative predictive value of 100% and a positive predictive value of 96.9% (62 out of 64) was assessed. Conclusions: Fully automatized Genexus system combined with OPA (Thermofisher Scientifics) may be considered a technically valuable, saving time sequencing platform to test predictive biomarkers in diagnostic routine practice.

3 October 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
MSMauro Scimia
Mauro Scimia
FPFrancesco Pepe
Francesco Pepe
Gianluca RussoGianluca Russo
Gianluca Russo
UMUmberto Malapelle
Umberto Malapelle
SSSimone Scimia
Simone Scimia
Giancarlo TronconeGiancarlo Troncone
Giancarlo Troncone
Background: Colorectal Cancer screening programs are effective in reducing incidence and mor-tality. In Europe, every FIT+ patient is referred to colonoscopy. Available data shows that ~75.0% of these patients are negative. It is desirable to select patients at greater risk of having a positive colonoscopy. Methods: 711 subjects, aged 50-74, attending the screening program of ASL-NA-3-SUD (Na-ples, Italy), were enrolled in a cross-sectional study to evaluate the performance of QuantiDNA™ test and non-inferiority of an alternative approach (AAP). This evaluation is based on FIT+ and QuantiDNA™+ patients referred to colonoscopy, compared to Standard of Care (SOC), colon-oscopy following a FIT+ test alone. A non-inferiority margin for Colorectal Neoplasia (CN) and Advanced Adenomas (AA) was set at -10% and at -3.8% for CRC. Results: The odds ratio was 1.76 (p-value= 0.009). The detection rate of AAP was 15.9% for colorectal neoplasia (CN), 13.0% for advanced adenoma (AA), and 3.0% for CRC. The risk dif-ference between AAP and SOC was -5.07% (95% C.I -9.23, -0.90) for CN, -4.02% (95% C.I. -7.89, -0.16) for AA, and -1.04% (95% C.I. -3.16, 1.07) for CRC. This data suggests that AAP is non-inferior to SOC for detecting CN, AA, and CRC. The expected decrease in colonoscopies is 33.4%. Conclusions: The QuantiDNA™ test is straightforward, non-invasive, and well-tolerated. Data from this study indicates it is effective in the reduction of the need for colonoscopy examina-tions (-33.4%) and is non-inferior to SOC in the detection of significant colorectal lesions.