Gage Redler

Dr. Gage Redler


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2023 in Cancers
Verified
Journal Article
Open access
PDF file
JBJohn Michael Bryant
John Michael Bryant
JWJoseph Weygand
Joseph Weygand
EKEmily Keit
Emily Keit
RCRuben Javier Cruz-Chamorro
Ruben Javier Cruz-Chamorro
MSMaria Luisa Sandoval
Maria Luisa Sandoval
SRStephen A. Rosenberg
Stephen A. Rosenberg
Stereotactic body radiotherapy (SBRT) is an effective radiation therapy technique that has allowed for shorter treatment courses, as compared to conventionally dosed radiation therapy. As its name implies, SBRT relies on daily image guidance to ensure that each fraction targets a tumor, instead of healthy tissue. Magnetic resonance imaging (MRI) offers improved soft-tissue visualization, allowing for better tumor and normal tissue delineation. MR-guided RT (MRgRT) has traditionally been defined by the use of offline MRI to aid in defining the RT volumes during the initial planning stages in order to ensure accurate tumor targeting while sparing critical normal tissues. However, the ViewRay MRIdian and Elekta Unity have improved upon and revolutionized the MRgRT by creating a combined MRI and linear accelerator (MRL), allowing MRgRT to incorporate online MRI in RT. MRL-based MR-guided SBRT (MRgSBRT) represents a novel solution to deliver higher doses to larger volumes of gross disease, regardless of the proximity of at-risk organs due to the (1) superior soft-tissue visualization for patient positioning, (2) real-time continuous intrafraction assessment of internal structures, and (3) daily online adaptive replanning. Stereotactic MR-guided adaptive radiation therapy (SMART) has enabled the safe delivery of ablative doses to tumors adjacent to radiosensitive tissues throughout the body. Although it is still a relatively new RT technique, SMART has demonstrated significant opportunities to improve disease control and reduce toxicity. In this review, we included the current clinical applications and the active prospective trials related to SMART. We highlighted the most impactful clinical studies at various tumor sites. In addition, we explored how MRL-based multiparametric MRI could potentially synergize with SMART to significantly change the current treatment paradigm and to improve personalized cancer care.

23 January 2018 in Medical Physics
Verified
Journal Article
Closed access
PDF file
GRGage Redler
Gage Redler
KJKevin C. Jones
Kevin C. Jones
ATAlistair Templeton
Alistair Templeton
DBDamian Bernard
Damian Bernard
JTJulius Turian
Julius Turian
JCJames C. H. Chu
James C. H. Chu

1 September 2018 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
ZQZhiwei Qiao
Zhiwei Qiao
ZZZheng Zhang
Zheng Zhang
XPXiaochuan Pan
Xiaochuan Pan
BEBoris Epel
Boris Epel
GRGage Redler
Gage Redler
HHHoward J. Halpern
Howard J. Halpern

24 January 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
MKMark C. Korpics
Mark C. Korpics
MRMichelle Rokni
Michelle Rokni
MDMichael Degnan
Michael Degnan
BABulent Aydogan
Bulent Aydogan
SLStanley Liauw
Stanley Liauw
GRGage Redler
Gage Redler
Background: Fiducial markers are frequently used before treatment for image‐guided patient setup in radiation therapy (RT), but can also be used during treatment for image‐guided intrafraction motion detection. This report describes our implementation of automatic marker detection with periodic kV imaging (TrueBeam v2.5) to monitor and correct intrafraction motion during prostate RT.Methods: We evaluated the reproducibility and accuracy of software fiducial detection using a phantom with 3 implanted fiducial markers. Clinical implementation for patients with intraprostatic fiducials receiving volumetric modulated arc therapy (VMAT) utilized periodic on‐board kV imaging with 10 s intervals during treatment delivery. For each image, the software automatically identified fiducial locations and determined whether their distance relative to planned locations were within a 3 mm tolerance. Motion was corrected if either ≥2 fiducials in a single image or ≥1 fiducial in sequential images were out of tolerance.Results: Phantom studies demonstrated poorer performance of linear fiducials compared to collapsible fiducials, and wide variability to accurately detect fiducials across eight software settings. For any given setting, results were relatively reproducible and precise to ~0.5 mm. Across 17 patients treated with a median of 20 fractions, the software recommended a shift in 44% of fractions, and a shift was actually implemented after visual confirmation of movement greater than the 3 mm threshold in 20% of fractions. Adjustment of our approach led to improved accuracy for the latter (n = 7) patient subset. On average, table repositioning added 3.0 ± 0.3 min to patient time on table. Periodic kV imaging increased skin dose by an estimated 1 cGy per treatment arc.Conclusions: Periodic kV imaging with automatic detection of motion during VMAT prostate treatments is commercially available, and can be successfully implemented to mitigate effects of intrafraction motion with careful attention to software settings.

1 February 2015 in Concepts in Magnetic Resonance Part B
Verified
Journal Article
Closed access
PDF file
GRGage Redler
Gage Redler
BEBoris Epel
Boris Epel
HHHoward J. Halpern
Howard J. Halpern

24 April 2023 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
MKMadison Kozee
Madison Kozee
JWJoseph Weygand
Joseph Weygand
JAJacqueline M. Andreozzi
Jacqueline M. Andreozzi
DHDylan Hunt
Dylan Hunt
BPBradford A. Perez
Bradford A. Perez
GRGage Redler
Gage Redler
3D printing in medical physics provides opportunities for creating patient‐specific treatment devices and in‐house fabrication of imaging/dosimetry phantoms. This study characterizes several commercial fused deposition 3D printing materials with some containing nonstandard compositions. It is important to explore their similarities to human tissues and other materials encountered in patients. Uniform cylinders with infill from 50 to 100% at six evenly distributed intervals were printed using 13 different filaments. A novel approach rotating infill angle 10o between each layer avoids unwanted patterns. Five materials contained high‐Z/metallic components. A clinical CT scanner with a range of tube potentials (70, 80, 100, 120, 140 kVp) was used. Density and average Hounsfield unit (HU) were measured. A commercial GAMMEX phantom mimicking various human tissues provides a comparison. Utility of the lookup tables produced is demonstrated. A methodology for calibrating print materials/parameters for a desired HU is presented. Density and HU were determined for all materials as a function of tube voltage (kVp) and infill percentage. The range of HU (−732.0–10047.4 HU) and physical densities (0.36–3.52 g/cm3) encompassed most tissues/materials encountered in radiology/radiotherapy applications with many overlapping those of human tissues. Printing filaments doped with high‐Z materials demonstrated increased attenuation due to the photoelectric effect with decreased kVp, as found in certain endogenous materials (e.g., bone). HU was faithfully reproduced (within one standard deviation) in a 3D‐printed mimic of a commercial anthropomorphic phantom section. Characterization of commercially available 3D print materials facilitates custom object fabrication for use in radiology and radiation oncology, including human tissue and common exogenous implant mimics. This allows for cost reduction and increased flexibility to fabricate novel phantoms or patient‐specific devices imaging and dosimetry purposes. A formalism for calibrating to specific CT scanner, printer, and filament type/batch is presented. Utility is demonstrated by printing a commercial anthropomorphic phantom copy.