Tool wear prediction is of great significance in industrial production. Current tool wear prediction methods mainly rely on the indirect estimation of machine learning, which focuses more on estimating the current tool wear state and lacks effective quantification of random uncertainty factors. To overcome these shortcomings, this paper proposes a novel method for predicting cutting tool wear. In the offline phase, the multiple degradation features were modeled using the Brownian motion stochastic process and a SVR model was trained for mapping the features and the tool wear values. In the online phase, the Bayesian inference was used to update the random parameters of the feature degradation model, and the future trend of the features was estimated using simulation samples. The estimation results were input into the SVR model to achieve in-advance prediction of the cutting tool wear in the form of distribution densities. An experimental tool wear dataset was used to verify the effectiveness of the proposed method. The results demonstrate that the method shows superiority in prediction accuracy and stability.
An alternative to conventional posterior lumbar interbody fusion (PLIF) is a PLIF with transpedicular oblique screw fixation system. An assessment of new fixation system's viability and efficacy is conducted through a comparison of its biomechanical properties with those of conventional PLIF. A comprehensive finite element model (FEM) of the lumbar regions L1-L5 was developed and the surgical segment L3-L4 was chosen to comprise the surgical models of both traditional PLIF and new PLIF. In new PLIF model, an analysis was conducted on segmental range of motion (RoM), cage stress, inferior endplates stress, vertebral stress, and internal fixation stress. Three-dimensional printers are utilized to fabricate and assemble the fusion cage and vertebrae, and compression test machines are employed to execute physiological load and extreme load experiments on new PLIF, so as to verify the accuracy of the FEM analysis and the mode of fatigue exhibited by new PLIF. In new PLIF, the maximum stress on the inferior endplates under physiological loads was reduced in comparison to conventional PLIF. While the maximum stress on the cage, vertebral body, and screw increased, it remained within an acceptable range. The experimental data indicates that new fixation system can endure a vertical load exceeding 2800 N and an ultimate bending moment of 77 Nm. The new PLIF exhibits a comparable RoM to its predecessor, simultaneously mitigating inferior endplate stress and accommodating physiological loads, which reduce the amount of surgical incision and fusion fixation instruments. Consequently, it emerges as a sanguine surgical approach to fuse the degenerative lumbar spine.