Yuanjun Sun

Dr. Yuanjun Sun

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2020 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
YSYuanjun Sun
Yuanjun Sun
XYXiaohong Yu
Xiaohong Yu
XXXianjie Xiao
Xianjie Xiao
XYXiaomeng Yin
Xiaomeng Yin
LGLianjun Gao
Lianjun Gao
YXYunlong Xia
Yunlong Xia

26 August 2022 in Medicine
Verified
Journal Article
Open access
YSYuanjun Sun
Yuanjun Sun
XYXiaohong Yu
Xiaohong Yu
XXXianjie Xiao
Xianjie Xiao
SDSHIYU DAI
SHIYU DAI
ZRZhang Rongfeng
Zhang Rongfeng
YXYunlong Xia
Yunlong Xia
Rationale: We reported a case with cardiomyopathy induced by frequent premature ventricular contractions (PVCs) and followed ventricular escape beats (VEBs). PVCs with VEBs in the compensatory pause which induced cardiomyopathy is rarely reported. Also, the case exhibited many characteristics of PVCs which were more likely to induce cardiomyopathy, like the location of origin, the longer coupling interval, and the QRS wave companied with the P wave. Patient concerns: A 53-year-old man with left ventricular (LV) dysfunction presented with palpation, chest distress, and dyspnea for 3 years. Holter revealed a high burden of ventricular rhythm of PVCs and another wide QRS patterns (96,562 total beats with 87,330 wide QRS beats in 24 hours). The LV ejection fraction decreased to 34% and the left ventricle, right and left atria all dilated. Diagnosis: He was diagnosed with PVC-induced cardiomyopathy. Interventions: The patient experienced intracardiac electrophysiological examination which revealed frequent PVCs followed by VEBs in the compensatory pause. Activation mapping of the PVCS and ablation were performed. Outcomes: PVCs and VEBs disappeared after ablation. The LV ejection fraction increased to 46% at 2 days after the procedure. The diameters of the right and left atria were also significantly reduced. Lessons: VEBs may occur during the compensatory pause of PVCs. PVCs with VEBs can lead to a high burden of ventricular rhythm and LV dysfunction. Ablation of the PVCs can also eliminate VEBs and improve the LV function.

10 December 2024 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
JXJuan Xu
Juan Xu
SPShi Peng
Shi Peng
YSYuanjun Sun
Yuanjun Sun
ZNZhenning Nie
Zhenning Nie
YZYa Zhen
Ya Zhen
SCSongwen Chen
Songwen Chen

Verified
Journal Article
Open access
PDF file
SLSongbing Long
Songbing Long
YSYuanjun Sun
Yuanjun Sun
XXXianjie Xiao
Xianjie Xiao
ZWZhongzhen Wang
Zhongzhen Wang
WSWei Sun
Wei Sun
XYXiaomeng Yin
Xiaomeng Yin
(1) Background: A plethora of studies have elucidated the safety and efficacy of catheter ablation (CA) for patients afflicted with atrial fibrillation (AF) and concomitant reduction in left ventricular ejection fraction (LVEF). Nevertheless, the literature on the benefits of CA in the specific etiological context of heart failure (HF) remains limited. This study delineates a comparative assessment of outcomes for patients with AF and reduced LVEF across the primary etiologies. (2) Methods: Our inquiry encompassed 216 patients diagnosed with congestive heart failure and an LVEF of less than 50 percent who were referred to our institution for circumferential pulmonary vein isolation (CPVI) between the years 2016 and 2020. The selection criteria included a detailed medical history while excluding those suffering from valvular disease, congenital heart disease, and hypertrophic cardiomyopathy. In an effort to scrutinize varying etiologies, patients were stratified into three categories: dilated cardiomyopathy (DCM, n = 56, 30.6%), ischemic cardiomyopathy (ICM, n = 68, 37.2%), and tachycardia-induced cardiomyopathy (TIC, n = 59, 32.2%). (3) Results: Following an average (±SD) duration of 36 ± 3 months, the prevalence of sinus rhythm was 52.1% in the DCM group, 50.0% in the ICM group, and 68.14% in the TIC group (p = 0.014). This study revealed a significant disparity between the DCM and TIC groups (p = 0.021) and the ICM and TIC groups (p = 0.007), yet no significant distinction was discerned between the TIC and ICM groups (p = 0.769). Importantly, there were no significant variations in the application of antiarrhythmic drugs or recurrence of procedures among the three groups. The mortality rates were 14.29% for the DCM group and 14.71% for the ICM group, which were higher than the 3.39% observed in the TIC group (DCM vs. TIC p = 0.035 (HR = 4.50 (95%CI 1.38–14.67)), ICM vs. TIC p = 0.021 (HR = 5.00 (95%CI 1.61–15.50))). A noteworthy enhancement in heart function was evidenced in the TIC group in comparison to the DCM and ICM groups, including a higher LVEF (p < 0.001), diminution of LV end-diastolic diameter (p < 0.001), and an enhanced New York Heart Association classification (p = 0.005). Hospitalization rates for heart failure were discernibly lower in TIC patients (0.98 (0,2) times) relative to those with DCM (1.74 (0,3) times, p < 0.01) and TIC (1.78 (0,4) times, p < 0.001). Patients with paroxysmal atrial fibrillation and brief episodes were found to achieve superior clinical outcomes through a catheter ablation strategy. (4) Conclusion: Patients diagnosed with TIC demonstrated a more pronounced benefit from catheter ablation compared to those with DCM and ICM. This encompassed an augmented improvement in cardiac function, an enhanced maintenance of sinus rhythm, and a reduced mortality rate.

13 November 2026 in EP Europace
Verified
Journal Article
Open access
GZGenqing Zhou
Genqing Zhou
XWXiaoyu Wu
Xiaoyu Wu
LZLiangrong Zheng
Liangrong Zheng
JLJingbo Li
Jingbo Li
YXYunlong Xia
Yunlong Xia
SLShaowen Liu
Shaowen Liu
Aims: The efficacy of left atrial posterior wall isolation (PWI) for persistent atrial fibrillation (AF) is controversial. We propose a modified left atrial posterior wall ablation strategy. Objectives: To evaluate the efficacy and safety of modified posterior wall ablation in patients with persistent AF who underwent first-time radiofrequency catheter ablation. Methods and results: In this multicenter, single-blind randomized trial, 276 patients with persistent AF were assigned 1:1 to pulmonary vein isolation (PVI) with (BOX+) or without modified posterior wall ablation (BOX−). Seven participants withdrew, leaving 269 (BOX+, n=139; BOX−, n=130) for primary endpoint analysis. The primary endpoint was freedom from any documented atrial arrhythmia lasting > 30 seconds without antiarrhythmic drugs after a 3 -month blanking period. At 12-month follow-up, the primary endpoint occurred in 120 of 139 patients (86.3%) in the BOX+ group and 113 of 130 (86.9%) in the BOX− group (hazard ratio 1.046, 95% CI, 0.54 - 2.01; P = 0.894). The BOX+ group exhibited longer procedure time and ablation time. Acute successful PWI was achieved in 91 (65.5%) patients assigned to BOX+. In a nonprespecified, post-randomization analysis, arrhythmia-free survival was 93.4% in patients with acute successful PWI, 72.9% in those with attempted but unsuccessful PWI, and 86.9% in controls without attempted PWI (overall log-rank P=0.002). Adverse events were similar between groups. Conclusion: Routine addition of modified posterior wall ablation did not improve overall outcomes of first-time ablation in persistent AF. However, achieving successful PWI was associated with significantly lower recurrence.