The occurrence of microplastics in many, if not all environmental compartments is a matter of increasing concern and deserves proper attention. However, there is still a lack of analytical tools for straightforward monitoring of these tiny plastic particles at environmentally relevant levels in water. Inductively coupled plasma-mass spectrometry (ICP-MS) operated in single-particle mode (SP-ICP-MS) was demonstrated to be a powerful technique for the characterization of metallic nanoparticles, but to the best of the authors' knowledge, SP-ICP-MS has not yet been evaluated for the purpose of detection of microplastics and their quantitative determination (particle number density). In this work, spherical polystyrene microspheres of 1 and 2.5 μm – to mimic microplastics coming from plastic waste – have been detected using ICP-MS. The approach developed relies on the ultra-fast monitoring of transient signals (with a dwell time of 100 μs) when using a quadrupole-based ICP-MS unit in the so-called single-event mode and registering the signal spikes produced by individual microparticles by monitoring the signal intensity at a mass-to-charge ratio (m/z) of 13 (13C+). The accuracy of the number-based concentration results (particle number densities) has been assessed by comparing the number of events detected when monitoring 13C+ to those detected when monitoring 165Ho+ for 2.5 μm lanthanide-doped polystyrene beads. Additionally, the results obtained for both polystyrene microspheres in terms of size (most frequently occurring intensity of the signal distribution) compare well with the size as determined using electron microscopy. ICP-MS operated in single-event mode thus allows information on both the size distribution and mass concentration of microplastics to be obtained. As this approach makes use of instrumentation already available in many routine labs analyzing environmental samples, it can enable these labs to analyze microplastics by using their instrument in single-event mode.
15 March 2021 in Journal of Analytical Atomic Spectrometry
Development of analytical methods for the characterization (particle size determination, chemical identification, and quantification) of the low μm-range microplastics (MPs; 1–10 μm) and nanoplastics (NPs; 1 nm to 1 μm) in air – coarse (PM10; <10 μm), fine (PM2.5; <2.5 μm) and ultrafine (PM1; <1 μm) particulate matter – is a quickly emerging scientific field as inhalation has been identified as one of the main routes of human exposure. The respiratory tract may serve as both target tissue and port of entry to the systemic circulation for the inhaled MPs and NPs with their small particle size. As an outcome, the interest of the scientific community, policy makers, and the general public in indoor airborne MPs and NPs increased tremendously. However, there is a lack of detailed knowledge on the indoor and outdoor sources of MPs and NPs, their levels, and their health impact. This is mainly related to a lack of standardized sampling and analytical methods for size determination, chemical identification, and quantification. In this review, recent developments in mass spectrometry-based analytical methods for size determination, chemical identification, and quantification of the MPs and NPs in indoor air and dust, are discussed.
1 March 2013 in Isotopes in Environmental and Health Studies
In spite of increasing efforts to reduce nitrogen inputs into ground water from intensive agriculture, nitrate (NO3) remains one of the major pollutants of drinking-water resources worldwide, with NO3 levels approaching the defined limit of 50 mg l−1 in an increasing number of water bodies. Determining the source(s) of contamination in water is an important first step for improving its quality by emission control. The Life ISONITRATE project aimed at showing the benefit of a multi-isotope approach (δ15N and δ18O of NO3, and δ11B), in addition to conventional hydrogeological analysis, to track the origin of NO3 contamination in water. Based on land use and local knowledge, four distinct cases were studied: (1) natural soil NO3, (2) natural denitrification, (3) single source of NO3 pollution and (4) multiple sources of NO3 pollution. Our results show the added value of combining isotope information, compared to knowledge based on local authorities’ experience, land use and the ‘classical’ chemical approach, by efficiently identifying the number and type of NO3 source(s) for each watershed studied.
Background: Food-grade TiO2 (E171 in the EU) is widely used as a coloring agent in foodstuffs, including sweets. Chronic dietary exposure raises concerns for human health due to proinflammatory properties and the ability to induce and promote preneoplastic lesions in the rodent gut. Characterization of intestinal TiO2 uptake is essential for assessing the health risk in humans. We studied in vivo the gut absorption kinetics of TiO2 in fasted mice orally given a single dose (40 mg/kg) to assess the ability of intestinal apical surfaces to absorb particles when available without entrapment in the bolus. The epithelial translocation pathways were also identified ex vivo using intestinal loops in anesthetized mice. Results: The absorption of TiO2 particles was analyzed in gut tissues by laser-reflective confocal microscopy and ICP-MS at 4 and 8 h following oral administration. A bimodal pattern was detected in the small intestine: TiO2 absorption peaked at 4 h in jejunal and ileal villi before returning to basal levels at 8 h, while being undetectable at 4 h but significantly present at 8 h in the jejunal Peyer’s patches (PP). Lower absorption occurred in the colon, while TiO2 particles were clearly detectable by confocal microscopy in the blood at 4 and 8 h after treatment. Ex vivo, jejunal loops were exposed to the food additive in the presence and absence of pharmacological inhibitors of paracellular tight junction (TJ) permeability or of transcellular (endocytic) passage. Thirty minutes after E171 addition, TiO2 absorption by the jejunal villi was decreased by 66% (p < 0.001 vs. control) in the presence of the paracellular permeability blocker triaminopyrimidine; the other inhibitors had no significant effect. Substantial absorption through a goblet cell (GC)-associated pathway, insensitive to TJ blockade, was also detected. Conclusions: After a single E171 dose in mice, early intestinal uptake of TiO2 particles mainly occurred through the villi of the small intestine, which, in contrast to the PP, represent the main absorption surface in the small intestine. A GC-associated passage and passive diffusion through paracellular TJ spaces between enterocytes appeared to be major absorption routes for transepithelial uptake of dietary TiO2.
The aim of our research was to compare δ11B measurements performed with thermal ionization mass spectrometry (TIMS) and sector field-inductively coupled plasma-mass spectrometry (SF-ICP-MS) and evaluate the feasibility of implementing stable isotope methods in European water framework directive (WFD) monitoring programs. The comparison was based on δ11B measurements of 192 ground- and surface water samples and 15 leachates of nitrate pollution source materials (organic and mineral fertilisers). The precision of δ11B measurements attainable with SF-ICP-MS, 2σ= ± 2.6‰; (n = 192), is as expected lower than the precision achieved by TIMS, 2σ= ± 0.3‰ (n = 183). However the ease of use, rapidity and availability of SF-ICP-MS on one hand and the observed variability in δ11B in ground- and surface water on the other (from −3.4 to +37‰), demonstrates that using SF-ICP-MS as an isotopic screening method would promote the use of isotopic methodology for WFD monitoring. Based on the results of the different case studies it is shown that retrieving precise information on the identification of pollution sources from δ11B values requires reaching the best analytical precision and accuracy possible. Hence, the superior precision of TIMS advantages tracing of nitrate pollution sources. However for some cases, e.g. trying to decipher contributions between sources with really distinct δ11B signatures (e.g. manure and sewage effluent), SF-ICP-MS results lead to the same conclusions and can therefore be used as a first approachable screening method for the determination of δ11B in WFD monitoring programs.