Takahiro Hayashi

Dr. Takahiro Hayashi

orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2003 in Ultrasonics
Verified
Journal Article
Closed access
THTakahiro Hayashi
Takahiro Hayashi
WSWon-Joon Song
Won-Joon Song
JRJoseph L Rose
Joseph L Rose

1 May 2002 in Ultrasonics
Verified
Journal Article
Closed access
THTakahiro Hayashi
Takahiro Hayashi
KKKoichiro Kawashima
Koichiro Kawashima

1 January 2006 in Ultrasonics
Verified
Journal Article
Closed access
THTakahiro Hayashi
Takahiro Hayashi
CTChiga Tamayama
Chiga Tamayama
MMMorimasa Murase
Morimasa Murase

1 April 2005 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
THTakahiro Hayashi
Takahiro Hayashi
MMMorimasa Murase
Morimasa Murase
Guided wave techniques are expected to become an effective means for rapid, long-range inspection of pipes. Such techniques still have many practical difficulties in application, however, due to the complex characteristics of guided waves such as dispersion and their multimodal nature. A defect imaging technique is developed in this study to overcome the complexities of guided wave inspection. Received signals are separated into single-mode waveforms with a mode extraction technique and then spatial waveforms on the pipe surface at an arbitrary time are reconstructed. The predicted waveforms can provide a defect image at the moment when an incident wave arrives at a defect region, which is based on a time-reversal technique. This defect imaging technique is experimentally verified using eight signals detected at eight different circumferential positions. Images of artificial defects are obtained with one-hole and two-hole test pipes, and increasing the frequency of incident waves increases the resolution of the images. Holes and pipe ends are recognizable in the images, but the reconstructed images contain some errors in the area behind the defects where guided waves do not propagate or do not reflect back to the receiving transducers.

1 August 2014 in Ultrasonics
Verified
Journal Article
Closed access
THTakahiro Hayashi
Takahiro Hayashi
DIDaisuke Inoue
Daisuke Inoue

28 February 2003 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
THTakahiro Hayashi
Takahiro Hayashi
KKKoichiro Kawashima
Koichiro Kawashima
ZSZongqi Sun
Zongqi Sun
JRJoseph L. Rose
Joseph L. Rose
Focusing is one of the most promising techniques for the detection of small defects in pipe works, in which guided waves including longitudinal and flexural modes are tuned so that ultrasonic energy can be focused at a target point in a pipe, and analysis of reflected waves gives information on defects such as location and size. In this paper, the focusing technique is discussed by way of a simulation of guided wave propagation in pipe by a semianalytical finite element method (SAFE). Experiments and SAFE calculations were compared for waveforms transmitted by a single transducer and received at different circumferential positions initially, and then the focusing phenomena were experimentally observed using focusing parameters obtained by calculations. Calculation and visualization were conducted to clarify focusing phenomena in pipe in investigating the potential of the focusing technique. These results show that the time-reversal idea helps in understanding focusing and that resolution of focusing is strongly affected by incident waveforms as well as the number of channels available in an experiment.