Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.
13 August 2022 in International Journal of Hydrogen Energy
Bilinen en sert malzemelerden olan bor karbür (B4C) ve alümina seramik (Al2O3) plakaların eşsiz özelliklerinden dolayı dikkatleri çekmektedir. Bu çalışmada balistik koruma amaçlı kullanılan bor karbür (B4C) ve alümina (Al2O3) seramik plakaların iç yapı, mekanik ve balistik özellikleri incelenmiş ve literatürde yapılmış olunan benzer çalışmalarla sonuçları karşılaştırılmıştır. B4C ve Al2O3 içeriği homojen bir dağılım göstermekte olup sırası ile yoğunlukları 2.52 g/cm3 ve 3.85 g/cm3 olarak ölçülmüştür. B4C ve Al2O3 numuneleri gevrek kırılma özelliği sergilemekte ve düşük gerilimlerde lineer deformasyon oluşturmaktadır. Elastik özellikler bor karbür içeriğindeki karbon oranına göre değişmektedir. Bor karbür plakanın elastisite modülü 440 GPa olarak elde edilmiştir. B4C ve Al2O3 plakalar, askeri standartlara uygun olarak yapılan balistik testlerde IV. seviye tehditlere (hızı bor karbür plakasında 878 m/sn, alümina plakasında 884 m/sn olan 7.62x51 mm M2 AP mermide) karşı travma derinlikleri 28.8 mm ve 34.4 mm olmak üzere NIJ-STD-0101.07 standardı çerçevesinde tam koruma sağlamaktadır. B4C’nin yüksek sertliği nedeniyle Al2O3’e nazaran daha iyi balistik özellik göstereceği beklentisi, malzemenin aşırı gevrek olması nedeniyle mümkün olmamaktadır.
The purpose of this study was to combine hydroxyapatite (HA) with pumice and perlite. A precipitation procedure was applied for synthesizing pure and doped hydroxyapatite. Samples were sintered at 1100°C for 1 h. These doped structures are characterized by X-ray Diffraction (XRD), Scanning Electron Microscopy (SEM-EDS) and X-ray Fluorescence. Higher SiO2 and Al2O3 content was shown by XRF analysis. The XRD results revealed the existence of the HA, β-TCP and Ca5(PO4)2SiO4 phases. SEM images confirmed the sintering temperature and number of dopants had significant effect on grain sizes of the samples.
Titanium-based alloys are used in orthopedic applications as fixation elements, hard tissue replacements in artificial bones, and dental implants. Despite their wide range of applications, metallic implant defects and failures arise due to inadequate mechanical bonding, postoperative clotting problems, aseptic loosening, and infections. To improve the surface bioactivity and reduce the corrosion rate of the Ti6Al4V alloy, multi-layered coatings (HAp, BG, Cs, and Hep) were applied via electrophoretic deposition (EPD). XRD images showed the presence of HAp within the coating. In vitro investigation: cell line NIH-3T3 fibroblasts were seeded on the non-coated and coated Ti6Al4V substrates, and their cellular behavior was evaluated. The results indicated that the HApBGCsHep coating could enhance the adhesion and proliferation of NIH 3T3 cells. In addition, the potentiodynamic polarization results are compatible with the in vitro outcome.
1 December 2019 in Iğdır Üniversitesi Fen Bilimleri Enstitüsü Dergisi
En tr Calcium phosphate (CaP) based bioceramics are frequently used in dental and orthopedic field as bone grafts due to their chemical and structural similarities to the human hard tissues. Strontium (Sr2+), fluoride (F−) and chloride (Cl-) ions are known to play important role in bone and tooth microstructure. The aim of this study was to combine tri-calcium phosphates doped with strontium, chloride and fluoride ions. A precipitation procedure was applied for synthesizing pure and doped tri-calcium phosphates. The undoped and doped samples were sintered at 1100°C for 1 h. Incorporation of the strontium (Sr+2) and chloride (Cl-) ions decreased the density of the samples while, the fluoride (F-) co-doped densities increased with respect to pure TCP. The XRD results revealed the existence of the α-TCP and β-TCP phases. SEM results confirmed the sintering temperature and amount of dopants had prominent effect on the grain sizes of the samples. Diş ve ortopedik protezlerin üretiminde kalsiyum fosfat (CaP) bazlı biyoseramikler sıklıkla kullanılmaktadır. Özellikle, kemiğin kimyasal ve yapısal benzerliklerinden dolayı tercih edilmektedirler. Stronsiyum (Sr2+), florür (F−) ve klorür (Cl-) iyonlarının kemik ve dişlerin metabolizmasında ve yapısında önemli rol oynadığı bilinmektedir. Bu çalışmanın amacı stronsiyum, klorür ve florür iyonları ile katkılandırılmış tri-kalsiyum fosfatların üretilmesidir. Saf ve katkılandırılmış tri-kalsiyum fosfatlar çöktürme yöntemi kullanılarak sentezlenmiştir. Katkısız ve katkılandırılmış numuneler 1 saat süresince 1100°C ‘de sinterlenmiştir. Stronsiyum (Sr+2) ve klorürün (Cl-) ilavesi ile numunelerin yoğunluğunu azalırken, florür (F-) miktarının artmasıyla numunelerin yoğunluklarında artış gözlemlenmiştir. XRD sonuçları α-TCP ve β-TCP fazlarının varlığını ortaya koymuştur. SEM görüntüleri sinterleme sıcaklığının ve katkılandırılan iyon miktarlarının numuneler üzerindeki tane büyüklüklerine anlamlı bir etkiye sahip olduğunu doğrulamaktadır.