Aniello Donniacuo

Dr. Aniello Donniacuo

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2022 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
LBLorenzo Bellizzi
Lorenzo Bellizzi
GBGiuseppe Bevilacqua
Giuseppe Bevilacqua
Valerio BiancalanaValerio Biancalana
Valerio Biancalana
MCMario Carucci
Mario Carucci
RCRoberto Cecchi
Roberto Cecchi
LSLeonardo Stiaccini
Leonardo Stiaccini
We present a set of results obtained with an innovative eye-tracker based on magnetic dipole localization by means of an array of magnetoresistive sensors. The system tracks both head and eye movements with a high rate (100–200 Sa/s) and in real time. A simple setup is arranged to simulate head and eye motions and to test the tracker performance under realistic conditions. Multimedia material is provided to substantiate and exemplify the results. A comparison with other available technologies for eye-tracking is drawn, discussing advantages (e.g., precision) and disadvantages (e.g., invasivity) of the diverse approaches, with the presented method standing out for low cost, robustness, and relatively low invasivity.

15 June 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
GBGiuseppe Bevilacqua
Giuseppe Bevilacqua
Valerio BiancalanaValerio Biancalana
Valerio Biancalana
MCMario Carucci
Mario Carucci
RCRoberto Cecchi
Roberto Cecchi
Piero ChessaPiero Chessa
Piero Chessa
FVFrancesca Viberti
Francesca Viberti
A wireless, wearable magnetic eye tracker is described and characterized. The proposed instrumentation enables simultaneous evaluation of eye and head angular displacements. Such a system can be used to determine the absolute gaze direction as well as to analyze spontaneous eye re-orientation in response to stimuli consisting in head rotations. The latter feature has implications to analyze the vestibulo-ocular reflex and constitutes an interesting opportunity to develop medical (oto-neurological) diagnostics. Details of data analysis are reported together with some results obtained in-vivo or with simple mechanical simulators that enable measurements under controlled conditions.

4 July 2023 in Clinical Neurophysiology
Verified
Journal Article
Open access
Simone RossiSimone Rossi
Simone Rossi
ACAlessandra Cinti
Alessandra Cinti
FVFrancesca Viberti
Francesca Viberti
ABAlberto Benelli
Alberto Benelli
FNFrancesco Neri
Francesco Neri
Mandalà MarcoMandalà Marco
Mandalà Marco
The vestibular cortex is a multisensory associative region that, in neuroimaging investigations, is activated by slow-frequency (1-2 Hz) galvanic stimulation of peripheral receptors. We aimed to directly activate the vestibular cortex with biophysically modeled transcranial oscillatory current stimulation (tACS) in the same frequency range. Thirty healthy subjects and one rare patient with chronic bilateral vestibular deafferentation underwent, in a randomized, double-blind, controlled trial, to tACS at slow (1 or 2 Hz) or higher (10 Hz) frequency and sham stimulations, over the Parieto-Insular Vestibular Cortex (PIVC), while standing on a stabilometric platform. Subjective symptoms of motion sickness were scored by Simulator Sickness Questionnaire and subjects' postural sways were monitored on the platform. tACS at 1 and 2 Hz induced symptoms of motion sickness, oscillopsia and postural instability, that were supported by posturographic sway recordings. Both 10 Hz-tACS and sham stimulation on the vestibular cortex did not affect vestibular function. As these effects persisted in a rare patient with bilateral peripheral vestibular areflexia documented by the absence of the Vestibular-Ocular Reflex, the possibility of a current spread toward peripheral afferents is unlikely. Conversely, the 10 Hz-tACS significantly reduced his chronic vestibular symptoms in this patient. Weak electrical oscillations in a frequency range corresponding to the physiological cortical activity of the vestibular system may generate motion sickness and postural sways, both in healthy subjects and in the case of bilateral vestibular deafferentation. This should be taken into account as a new side effect of tACS in future studies addressing cognitive functions. Higher frequencies of stimulation applied to the vestibular cortex may represent a new interventional option to reduce motion sickness in different scenarios.

26 September 2024 in The Journal of International Advanced Otology
Verified
Journal Article
Open access
FVFrancesca Viberti
Francesca Viberti
GMGiovanni Monciatti
Giovanni Monciatti
ADAniello Donniacuo
Aniello Donniacuo
FFFabio Ferretti
Fabio Ferretti
LSLorenzo Salerni
Lorenzo Salerni
Mandalà MarcoMandalà Marco
Mandalà Marco
Background: The aim is to analyze Literature concerning mastoid obliteration in adults with either autologous or heterologous grafts in the last 10 years. Data Source: Databases such as NIH PubMed, Bookshelf, NLM Catalog, Cochrane Library, and Embase were consulted. Methods: Thirty-seven studies were selected (22 concerning autologous materials, 15 about heterologous ones). Only studies with more than 12 months of follow-up were considered. A statistical analysis with random-effects models was performed to allow the true effect sizes to differ from study to study. Results: The present literature review and meta-analysis does not allow to establish the supremacy of one technique over the other, but underlines the advantages of each reconstructive choice and the importance of mastoid obliteration in cholesteatoma surgery. The total number of obliterated ears was 2882. Overall otorrhea rate was 5% (5.2% for heterologous grafts; 4.9% for autologous materials; P < .05). Recurrent and residual cholesteatoma rate was 4.5% (3.4% in heterologous materials; 5.2% in autologous grafts; P < .05). Recurrent cholesteatoma rate was 1.8% (1.6% when using heterologous grafts, 1.9% with autologous; P < .05). Residual cholesteatoma rate was 1.5% (1.6% with heterologous materials, 1.5% with autologous; P < .05). TM (tympanic membrane) retraction pockets rate was 5.3% (3.6% with heterologous materials; P >.05; 7% with autologous materials; P < .05). TM perforations rate was 2.9% (4.3% with heterologous materials, 2.5% with autologous; P < .05). Infection rate was 2.3% (2.3% with heterologous materials, 2.2% with autologous; P < .05). Conclusion: Heterologous materials are associated with significantly lower rates of recurrent and residual cholesteatoma and retraction pockets development, although they are associated with higher rates of otorrhea and TM perforation. Cite this article as: Viberti F, Monciatti G, Donniacuo A, et al. Heterologous materials are really better than autologous in tympanoplasty mastoid obliteration? A systematic review with meta-analysis. J Int Adv Otol. 2024;20(5):439-449.

10 October 2023 in Brain Sciences
Verified
Journal Article
Open access
PDF file
ADAniello Donniacuo
Aniello Donniacuo
FVFrancesca Viberti
Francesca Viberti
MCMario Carucci
Mario Carucci
Valerio BiancalanaValerio Biancalana
Valerio Biancalana
LBLorenzo Bellizzi
Lorenzo Bellizzi
Mandalà MarcoMandalà Marco
Mandalà Marco
Over the past 20 years, several eye-tracking technologies have been developed. This article aims to present a new type of eye tracker capable of producing detailed information on eye and head movements using an array of magnetoresistive detectors fixed on the patient’s head and a small magnet inserted into a contact lens, adapted to the curvature of the cornea of the subject. The software used for data analysis can combine or compare eye and head movements and can represent them as 2D or 3D images. Preliminary data involve an initial patient who was asked to perform several tasks to establish the accuracy, reliability, and tolerance of the magnetic eye tracker and software. The tasks included assessment of saccadic eye movements and pursuit, “drawing” alphabetic shapes or letters, and reading. Finally, a Head Impulse Test (HIT) was performed to estimate the VOR gain, comparing the standard deviation established via vHIT with that established via this magnetic eye tracker (mHIT). This prototypical device is minimally invasive, lightweight, relatively cheap, and tolerable, with a high degree of reliability and precision. All these characteristics could lead to the future use of the magnetic eye tracker in neurological and otoneurological fields.

9 February 2024 in Clinical Neurophysiology
Verified
Journal Article
Open access
FNFrancesco Neri
Francesco Neri
CCChiara Cappello
Chiara Cappello
FVFrancesca Viberti
Francesca Viberti
ADAniello Donniacuo
Aniello Donniacuo
LBLucia Burzi
Lucia Burzi
Simone RossiSimone Rossi
Simone Rossi
Sensorineural hearing-loss (SHL) is accompanied by changes in the entire ear-brain pathway and its connected regions. While hearing-aid (HA) partially compensates for SHL, speech perception abilities often continue to remain poor, resulting in consequences in everyday activities. Repetitive transcranial magnetic stimulation (rTMS) promotes cortical network plasticity and may enhance language comprehension in SHL patients. 27 patients using HA and with SHL were randomly assigned to a treatment protocol consisting of five consecutive days of either real (Active group: 13 patients) or placebo rTMS (Sham group: 14 patients). The stimulation parameters were as follows: 2-second trains at 10 Hz, 4-second inter-train-interval, and 1800 pulses. Neuronavigated rTMS was applied over the left superior temporal sulcus. Audiological tests were administered before (T0), immediately after (T1), and one week following treatment completion (T2) to evaluate the speech reception threshold (SRT) and the Pure Tone Average (PTA). In the context of a general improvement likely due to learning, the treatment with real rTMS induced significant reduction of the SRT and PTA at T1 and T2 versus placebo. The long-lasting effects on SRT and PTA observed in the Active group indicates that rTMS administered over the auditory cortex could promote sustained neuromodulatory-induced changes in the brain, improving the perception of complex sentences and pure tones reception skills. Five days of rTMS treatment enhances overall speech intelligibility and PTA in SHL patients.